Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0227_Viessmann Product Submittal_1497223320.pdf
6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…1/18 Product Submittal Project: Location: Index: ► Boilers and Burners ► Boiler Controls ► System Accessories Vitodens 200W, B2HA112 WallMounted GasFired Condensing Boiler (Qty. of 2) Vitotronic 300K, MW2C Digital Cascade Control (Qty. of 1) Multiple Boiler LowLoss Distribution Manifold (Qty. of 1) 80 psig Pressure Relief Valve (Qty. of 2) Outdoor Temperature Sensor (Qty. of 2) DHW Temperature Sensor (Qty. of 2) LLH Temperature Sensor (Qty. of 2) 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…2/18 Boiler Data B2HA Series Full product manuals: Technical Data Manual Installation Instructions Operating Instructions Service Instructions Wiring Diagram Rigid & Flex Pipe Venting System Manual Common Venting System Manual 1.0 Technical Data for B2HA112 Natural Gas / Liquid Propane Gas CSA input *A 113 399 MBH 33 117 kW CSA output *B 103 375 MBH 30 110 kW DOE/AHRI Gross output 371 MBH 109 kW Net AHRI Rating *C 323 MBH 95 kW CSA thermal/combustion efficiency ANSI Z21.13/CSA 4.9 93.9 % Heat exchanger surface area 36.78 sq. ft.3.41 sq. m Min. gas supply pressure Natural gas 4 "w.c.996 Pa Liquid propane gas 10 "w.c.2491 Pa Max. gas supply pressure *1 Natural gas 14 "w.c.3487 Pa Liquid propane gas 14 "w.c.3487 Pa Weight 298 lbs 135 kg Boiler water content 4 USG 15 L Boiler max. flow rate *2 37.9 GPM 8600 L/h Max. operating pressure at 210°F (99°C)80 psig 5.5 bar Boiler water temperature – Adjustable high limit (AHL) range – space heating (steady state)68 to 180 °F 20 to 82 °C – DHW production 180 °F 82 °C – Fixed high limit (FHL)210 °F 99 °C Boiler connections Boiler heating supply and return 2 inch NPTM Pressure relief valve ¾inch NPTF Drain valve ¾inch Male thread Boiler supply/return for indirectfired DHW storage tank (field supplied) 2 inch NPT Gas valve connection 1 inch NPTF 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…3/18 Condensate connection (hose/nozzle diameter) *3 ¾ 1 inch Boiler flue gas connection (diameter) *4 4⅜inches 110 mm Combustion air supply (coaxial outer diameter)6 inches 150 mm Dimensions Overall depth 27.1 inches 698 mm Overall width 23⅝inches 600 mm Overall height *5 44½inches 1128 mm Flue gas *6 Temperature at boiler return temp. of 86°F (30°C) – At rated full load 124 °F 51 °C – At rated partial load 102 °F 39 °C Temperature at boiler return temp. of 140°F (60°C)158 °F 70 °C Max. condensate flow rate for NG and LPG *7 – At supply/return temp. of 104/86°F (40/30°C)4.35 USG/h 16.5 L/h Sound ratings – At maximum input 57 dB – At minimum input 40 dB Electrical ratings – main power supply Voltage 120 VAC Phase Single phase Frequency 60 Hz Current 12 Amps Notes: *A For high altitude installations 5,000 10,000 ft. (1500 m 3000 m), the input for model B2HA 88, 100 and 150 will have an altitude deration of 14% for 5,000 ft. (1500 m) and 29% for 10,000 ft. (3000 m); average of 2.8% / 1,000 ft. (305 m). The input for model B2HA 112 at 10,000 ft. (3000 m) will have an input derate of 13%. *B Output based on 180°F (82°C), 80°F (26°C) system supply/return temperature. *C Net AHRI rating based on piping and pickup allowance of 1.15. *1 If the gas supply pressure exceeds the maximum gas supply pressure value, a separate gas pressure regulator must be installed upstream of the heating system. *2 See "Typical System Flow Rates" starting on page 10 of the Technical Data Manual. *3 Requires 1 inch (25 mm) tubing. See the Installation Instructions of the Vitodens 200W, B2HA for details. *4 For side wall vent installations (coaxial system): Do not exceed max. equivalent length specified in the Installation Instructions of the Vitodens 200W, B2HA Venting System. Side wall coaxial vent installation must include Viessmann protective screen! For details refer to the Installation Instructions for the Vitodens 200W, B2HA Venting System. The Vitodens 200W can only be common vented with other Vitodens 200 W boilers of the same size and series. For details refer to the Common Venting Manual. *5 Add approximately 2½ inches (65 mm) for coaxial vent pipe transition adaptor. *6 Measured flue gas temperature with a combustion air temperature of 68°F (20°C). *7 Based on maximum input rate. 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…4/18 1.1 Dimensional Drawings Boiler Front and Side Views Legend A Boiler supply B Gas connection C Boiler return D Recommended height (single boiler system) E Condensate drain 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…5/18 1.2 Minimum Clearances Clearances to Combustibles Top 0" / 0 mm Front 0" / 0 mm for alcove or closet installations Rear 0" / 0 mm Sides 0" / 0 mm Vent pipe *1 0" / 0 mm Notes: *1 Refer to the Installation Instructions of the Vitodens 200W B2HA Venting System for details. The Vitodens 200W boiler has passed the zero inches vent clearance to combustibles testing requirements dictated by the Harmonized Standard ANSI Z21.13 CSA 4.9 (latest edition) and therefore is listed for zero clearance to combustibles when vented with a single wall special venting system (AL294C material). The zero inches vent clearance to combustibles for the Vitodens 200W boiler supercedes the clearance to combustibles listing that appears on the special venting system label. Recommended Minimum Service Clearances 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…6/18 1.3 Waterside Flow (Primary Circuit) Pressure Drop and Flow Rates For sizing an onsite circulation system. Maximum flow rate: 37.9 USGPM (8600 L/h) The Vitodens 200W is designed for closed loop, forced circulation hot water heating systems only. Use standard friction loss method for pipe sizing. Observe boiler maximum and minimum flow rate limitations. If system flow rate exceeds boiler maximum flow rate (as stated above), falls below the minimum flow rate or if system flow rate is unknown, Viessmann strongly recommends the installation of a lowloss header. An alternative method may be used, such as primary secondary piping using closely spaced tees. A lowloss header offers additional benefits not provided by a pair of closely spaced tees. Viessmann therefore strongly recommends and prefers the use of a lowloss header over closely spaced tees. Once the lowloss header is connected, the builtin low loss header logic of the Vitodens 200W boiler ensures the required Δt across the system through the sensory communication between the lowloss header and the boiler. 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…7/18 Control Data MW2C Series Full product manuals: Installation and Service Instructions Operating Instructions Wiring Diagram 1.0 Product Description Weathercompensated, digital cascade control unit for boiler and heating system control of up to 8 Vitodens 200W boilers. 1.1 Technical Data Rated voltage 120 V~ Rated frequency 60 Hz Rated current 6 A~ Power consumption 10 W Protection class I Permissible ambient temperature – During operation Installation in living spaces or boiler rooms (standard ambient conditions) 32 to 104°F 0 to +40°C – During storage and transport 4 to 149°F 20 to +65°C Rated relay output breaking capacity at 120 V~ [20]A1/M1 Heating circuit pump or Primary pump, primary store system 2 A~ * [21]Circulation pump for DHW tank heating 2 A~ * [28]DHW recirculation pump 2 A~ * [29]Distribution pump 2 A~ * [50]Central fault message 2 A~ * [52]A1/M1 Mixing valve motor or Motor, 3way mixing valve, primary store system 0.1 A~ * [20] M2 Heating circuit M2 pump 2 A~ * [20] M3 Heating circuit M3 pump 2 A~ * [52] M2 Heating circuit M2 pump, Mixing valve motor 0.1 A~ * [52] M3 Heating circuit M3 pump, Mixing valve motor 0.1 A~ * * Total max. 6 A~ (shared between all 120V outputs) 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…8/18 Legend PCB, extension for heating circuits 2 and 3 [2] M2/M3 Supply temperature sensor [20] M2/M3 Heating circuit pump [52] M2/M3 Mixing valve motor Main circuit board, low voltage [1]Outdoor temperature sensor [3]/[2]Supply temperature sensor, common supply temperature sensor/low loss header [5][A]DHW tank temperature sensor [5][B]DHW tank temperature sensor 2 for primary store system (accessory) [17][B]Temperature sensor primary store system (accessories) [143]External hookups [145]KM BUS participant (Vitotronic 200 and accessories, e.g. Vitotrol remote controls) [146]External hookups LON LON BUS, connecting cable for data exchange with the Vitotronic 200H and the Vitocom Main PCB 120V~ [20]A1 Heating circuit pump or Primary pump, primary store system [21]DHW pump [28]DHW recirculation pump [29]System pump [40]Power supply [50]Central fault message [52]A1 Motor for 3way mixing valve, primary store system [156]Internal power supply for mixing valve extension PCB 1.2 Control Diagrams Overview of Electrical Connections 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xSE…9/18 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…10/18 System Accessories Data Multiple Boiler LowLoss Distribution Manifold For Vitodens 200W, B2HA / B2HB Full product manuals: Installation Instructions 1.0 Product Description The MultiBoiler LowLoss Distribution Manifold is a prefabricated distribution and lowloss header system that allows from two to eight Vitodens 200W B2HA/B2HB boilers to be fully assembled, wired and piped prior to the installation. The manifold makes for fast and easy installation of a multiple Vitodens 200W system and decouples high flow rate systems from the boiler loop. Distribution manifolds are hydrostatically tested to 100 psig as well as checked for proper alignment. The distribution manifolds are free standing and shall be mounted to a floor capable of handling the weight of a fully assembled operational unit. 1.1 Technical Data for Distribution Manifold Number of boilers that can be mounted 2 boilers Manifold flanges 4 inch ANSI Water volume capacity 11.2 USG 42.6 L Weight (Dry)301.0 lbs 136.84 kg 1.2 Technical Data for LowLoss Header Model 200/120 Manifold side flange 4 inch ANSI System side flange 3 inch ANSI Water volume capacity 9.5 USG 36.2 L Weight (Dry)156.4 lbs 71.09 kg 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…11/18 1.3 Dimensional Drawings Manifold Top and Front Views Dimensions A 45⅜"1152 mm B 88⅛"2238 mm C 32⅜"822 mm D 75⅝"1920 mm 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…12/18 LowLoss Header Front and Side Views Dimensions A 7.9"200 mm B 5.9"150 mm C 4.7"120 mm D 64.6"1641 mm 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…13/18 System Accessories Data Pressure Relief Valve Conbraco 10 Series Bronze safety relief valve for protection of hot water boilers and heating systems. 1.0 Technical Data for Model 1041816 Set pressure 80 psig Certified capacity *1 1,027,000 Btu/hr Maximum temperature 250 °F 121 °C Connections Inlet size 3/4 inch NPT Female Outlet size 3/4 inch NPT Female Dimensions Height 2.75 inches 70 mm Weight 0.65 lbs 295 g Notes: *1 ASME HV Rating 90% of actual capacity at 10% overpressure. 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…14/18 System Accessories Data Outdoor Temperature Sensor Viessmann NTC 10K sensor, used to monitor the outdoor temperature. 1.0 Technical Data Sensor type NTC 10K ohms @ 77°F (25°C) Electrical connection – 2wire cable with max length of 115 ft 35 m – Minimum wire size AWG 18 copper – Cable to the outdoor sensor must not be laid near line voltage wiring (120/240V) Permissible ambient temperature – During operation, storage and transport 40 to +194 °F 40 to +90 °C 1.1 Dimensional Drawings Sensor Front View Dimensions D 1.6 in.41 mm H 3.2 in.80 mm W 2.6 in.66 mm 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…15/18 1.2 Diagrams Resistance vs Temperature 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…16/18 System Accessories Data DHW Temperature Sensor Viessmann NTC 10K immersiontype sensor, used to monitor the temperature in a DHW tank. 1.0 Technical Data Sensor type NTC 10K ohms @ 77°F (25°C) Supplied with: – Cable length (ready to plug in)12.3 ft 3.75 m – All pipe connections are field supplied Permissible ambient temperature – During operation 32 to 194 °F 0 to 90 °C – During storage and transport 4 to +158 °F 20 to +70 °C 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…17/18 1.2 Diagrams Resistance vs Temperature 6/9/2017 Viessmann Product Submittal http://www.vitoteam.com/Pages/eng/sub/submittal.php?b1=2xB2HA112&c1=MW2C&a1=LLDMB2112&a2=2xPRV9647464&a3=2xSENSOROTS&a4=2xS…18/18 System Accessories Data LLH Temperature Sensor Viessmann NTC 10K immersiontype sensor, used to monitor the temperature in a LowLoss Header. 1.0 Technical Data Sensor type NTC 10K ohms @ 77°F (25°C) Supplied with: – Cable length (fully wired)12.3 ft 3.75 m Permissible ambient temperature – During operation 32 to 194 °F 0 to 90 °C – During storage and transport 4 to +158 °F 20 to +70 °C Technical information subject to change without notice. Viessmann reserves the right to correct errors in graphics, files, text and technical data. Some product may not be exactly as illustrated. © Viessmann Manufacturing Company Inc. All rights reserved. Viessmann is a trademark of Viessmann Werke GmbH & Co. KG, and is registered with the U.S. Patent and Trademark Office. For further copyright, trademark and disclaimer information, please visit: www.viessmann.ca/en/copyright.html