Loading...
HomeMy WebLinkAboutE17-0013_ME1.0 plans approved.pdf 141' it 4 ie IS c MECHANICAL/ELECTRICAL SYSTEMS LEGEND ISSUE LOG MECHANICAL SPECIFICATIONS: MECHANICAL/ELECTRICALSHEET / / � // � ; / 03,28„, �� r� 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. �� / / , // POWER SYMBOLS ABBREVIATIONS PIPING SYMBOLS PIPING DESIGNATIONS 2. ALL CONTRACTORS SHALL BE LICENSED, EXPERIENCED,AND THOROUGHLY KNOWLEDGEABLE IN THEIR RESPECTIVE AREAS OF THE CONSTRUCTION INDUSTRY AND / // SHALL PERFORM IN A RESPONSIBLE MANNER WITH ESTABLISHED CONSTRUCTION SEQUENCE,SHALL RECOGNIZE THE PRIORITY OF THE CONSTRUCTION e- SINGLE RECEPTACLE AFC ABOVE FINISHED CEILING C 90° ELBOW DN / HYDRONIC PIPING DOCUMENTS,AND SHALL INFORM THE OWNER OF POTENTIAL PROBLEMS WHEN THE CONSTRUCTION DOCUMENTS ARE UNCLEAR OR INCONSISTENT. 0- 90° ELBOW UP DUPLEX RECEPTACLE AFF - ABOVE FINISHED FLOOR -HWS- HEATING WATER SUPPLY 3. INASMUCH AS DESIGN FOR REMODEL AND/OR REHABILITATION REQUIRES THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING CONDITIONS,AND BECAUSE CV DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER AFG - ABOVE FINISHED GRADE C TEE DOWN -HWR- HEATING WATER RETURN # TITLE SOME OF THESE ASSUMPTIONS CANNOT BE VERIFIED WITHOUT DESTROYING OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF THE BUILDING,THE ENGINEER TEE UP CANNOT ASSURE THE OWNER OR THE CONTRACTOR THAT THE PROFESSIONAL CONSULTING SERVICES HEREIN ENCOMPASS ALL CONTINGENCIES. FIELD V DOUBLE DUPLEX RECEPTACLE AHJ - AUTHORITY HAVING JURISDICTION COORDINATION DURING CONSTRUCTION IS IMPERATIVE. MAKE REASONABLE ALLOWANCES FOR UNSEEN CONDITIONS. -t[- BUTTERFLY VALVE ME-1.0 MECHANICAL/ELECTRICAL COVER SHEET J GFCI DUPLEX RECEPTACLE AL - ALUMINUM -SMS- SNOWMELT SUPPLY ME-1.1 MECHANICAL/ELECTRICAL FLOOR PLANS 4. THE EXISTING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT BE HINDERED BY THIS -14- SHUT OFF(BALL, GATE, BUTTERFLY) WORK. ACCOUNT FOR ALL ADDITIONAL COSTS WHICH MAY BE INCURRED DUE TO THE DIFFICULTY OF WORKING OVER AND AROUND EMPLOYEES, FURNITURE, DUPLEX RECEPTACLE; HALF SWITCHED AP ACCESS POINT -SMR- SNOWMELT RETURN ME 1.2 BOILER PIPING SCHEMATIC -IA- GLOBE VALVE E EQUIPMENT, ETC.;AND DUE TO THE HOURS OF THE DAY IN WHICH AN AREA MAY BE ACCESSIBLE WHEN COMPILING HIS BID]. v ISOLATED GROUND DUPLEX RECEPTACLE AWG - AMERICAN WIRE GAUGE On ,vZ E -iii- CHECK VALVE N 8 5. BE RESPONSIBLE TO FIELD VERIFY EXISTING EQUIPMENT OR DUCTWORK REMAINING TO BE CONNECTED TO NEW OR EXISTING SYSTEMS. PROVIDE DUCTWORK, ® MULTI-OUTLET PLUG STRIP BAS - BUILDING AUTOMATION SYSTEM PLUMBING PIPINGrde - o co -N- FLOW CONTROL VALVE - U O PIPING,CONTROLS, DIFFUSERS, ETC.,AS REQUIRED TO RESTORE CONTINUITY OF SYSTEM(S),OR TO MAKE NEW WORK MEET EXISTING CONDITIONS,WHETHER - 3 INDICATED OR NOT. FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE BFG - BELOW FINISH GRADE -G- NATURAL GAS 0o ® - BALL VALVE 4- O -MG- MEDIUM PRESSURE GAS w - 6. IF NOT SPECIFICALLY DEFINED IN THESE CONSTRUCTION DOCUMENTS, MATERIALS AND/OR EQUIPMENT SHALL BE IDENTIFIED BY THE SUBCONTRACTOR WITH ® FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE BMS - BUILDING MANAGEMENT SYSTEM -IQ- PLUG OR BALANCING VALVE ISSUE LOG KEY: 0 0 SUFFICIENT TIME TO ALLOW SELECTION, PURCHASE,AND DELIVERY TO MAINTAIN CONSTRUCTION SCHEDULE. z '- w . © FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED C - CONDUIT FLOW BALANCING VALVE '-\I' ISSUED AS PART OF A SETLIJ o - > 3 - D -- DRAIN PIPE ' NOT PART OF SET o Q H w 7. PROVIDE MECHANICAL DEMOLITION AS REQUIRED. REFER TO DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. VISIT SITE PRIOR TO © FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM CATV - COMMUNITY(CABLE)ANTENNA TELEVISION SYSTEM -p PLUG VALVE IN RISER '*' ISSUED FOR INFORMATION ONLY QM J o BID TO DETERMINE EXTENT OF WORK INVOLVED. EXISTING FIXTURES, MECHANICAL EQUIPMENT, ETC., BEING REMOVED SHALL BE RETURNED TO THE OWNER. 7� �! - E - DISPOSE OF ALL REMOVED PIPING, DUCTWORK, ETC. UNLESS NOTED OTHERWISE. PIPES, DUCTWORK, EQUIPMENT, ETC.TO BE REMOVED,ARE SHOWN HATCHED, WALL MOUNTED SPECIAL OUTLET AS NOTED CCTV - CLOSED CIRCUIT TELEVISION C GATE OR GLOBE VALVE IN RISER 0 oo O UNLESS OTHERWISE NOTED. -CW- DOMESTIC WATER 00 > SPECIAL OUTLET AS NOTED CKT - CIRCUIT DRAIN VALVE W/HOSE END -HW- DOMESTIC HOT WATER nnITA H 8. ALL DUCTWORK, DIFFUSERS, PIPING, FIXTURES,AND EQUIPMENT SHOWN IN LIGHT LINE WEIGHT IS EXISTING, NEW INDICATED BY HEAVIER LINE WEIGHT, EXCEPT -011- V > TEMPERATURE CONTROL VALVE(2-WAY) . 5 WHERE NOTED. PIPES, DUCTWORK, EQUIPMENT, ETC.TO BE REMOVED,ARE SHOWN HATCHED. 0 JUNCTION BOX CPU CENTRAL PROCESSING UNIT -HWC- DHW RECIRCULATION r"1 AM QJ -I WALL MOUNTED JUNCTION BOX CT - CURRENT TRANSFORMER TEMPERATURE CONTROL VALVE(3 WAY) -140° HW- DOMESTIC HOT WATER(TEMP. SHOWN) ELECTRICAL SPECIFICATIONS: " 0 o E 9. OFFSET PIPING, DUCTWORK, ETC.AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS,AND COLUMNS,AND EXISTING EQUIPMENT. -Oh- PRESSURE REDUCING VALVE 0 P_ 1. CONTRACTOR SHALL REVIEW ARCHITECTURAL, MECHANICAL,AND OTHER DRAWINGS. D N FLOOR MOUNTED JUNCTION BOX DISP - GARBAGE DISPOSAL m M 10. ALL EXISTING SUPPORT RODS AND STRAPS NOW SUPPORTING DUCTS, PIPES,AIR TUBING, ELECTRICAL CONDUIT, ETC.THAT ARE REMOVED TO ALLOW ROOM FOR -al- SOLENOID VALVE Q INSTALLATION OF NEW EQUIPMENT SHALL BE RELOCATED AND REINSTALLED, OR REPLACED IF DAMAGED. e DIVISION 15 EQUIPMENT POWER CONNECTION DW - DISHWASHER --F- FIRE LINE 2. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. co VENTURI/FLOW INDICATOR 11. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT,OWNER,AND ENGINEER. p TIMER SWITCH (E) EXISTING -O,- PUMP&EQUIPMENT CONNECTOR 3. ALL NEW CONSTRUCTION SHALL ADHERE TO REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE,2003 INTERNATIONAL BUILDING -PW- PRESSURIZED WASTE CODE,2003 INTERNATIONAL ENERGY CONSERVATION CODE,AND ALL OTHER LOCAL BUILDING CODES. IN THE EVENT OF A CONFLICT 12. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM HIS/HER WORK IN CONFORMANCE WITH ALL APPLICABLE CODES,ORDINANCES AND LIFE SAFETY FEATURES ❑p FUSED DISCONNECT EM EMERGENCY -III- PIPE UNION BETWEEN THE CONSTRUCTION DOCUMENTS AND THE DOCUMENTS LISTED ABOVE,THE CONTRACTOR SHALL CONSULT THE ENGINEER AS REQUIRED BY LOCAL, STATE,OR NATIONAL AUTHORITIES. THE CONTRACTOR SHALL VERIFY WITH THE ARCHITECT IF MODIFICATION OF HIS/HER WORK IS -W - WASTE PIPE OF RECORD PRIOR TO PROCEEDING WITH THE INSTALLATION IN QUESTION. Di NON FUSED DISCONNECT EWC - ELECTRIC WATER COOLER -04VSDo- DOUBLE CHECK BACKFLOW PREVENTER REQUIRED FOR COMPLIANCE. V PLUMBING VENT PIPE MOTOR STARTER FA - FIRE ALARM � PIPE ANCHOR 4. "PROVIDE"SHALL BE DEFINED AS"FURNISH AND INSTALL." f--\f--\ i .. 13. ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE,OR EXCEED THE MINIMUM MATERIAL AND METHOD REQUIREMENTS OF THE 2015 VERSION OF THE ® -X- N INTERNATIONAL BUILDING, MECHANICAL, PLUMBING, ENERGY CONSERVATION,AND FIRE CODES AND THE 2014 NATIONAL ELECTRICAL CODE, MOST CURRENT NFPA, ® ENCLOSED CIRCUIT BREAKER FACP - FIRE ALARM CONTROL PANEL -DIED- PIPE EXPANSION JOINT 5. PROVIDE ALL PERMITS AND INSPECTIONS REQUIRED. ALL LOCAL ORDINANCES AND AMENDMENTS AND MANUFACTURER'S INSTALLATION RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS EXISTS, PULL BOX FBO FURNISHED BY OTHERS FLEXIBLE CONNECTOR + 1 11I�f THE MOST STRINGENT REQUIREMENT SHALL APPLY. 6. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND SHALL NOT BE USED TO SCALE. VERIFY DIMENSIONS ON ARCHITECTURAL i SAFETY RELIEF VALVE DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL COORDINATE LIGHT FIXTURES, DEVICES,AND �:`'Qr ••'� w1* 14. PAY FOR AND SECURE ALL REQUIRED PERMITS AND INSPECTIONS. • PUSH BUTTON GC GENERAL CONTRACTOR )4,k,❑ } EQUIPMENT LOCATIONS WITH THE WORK OF OTHER TRADES PRIOR TO ROUGH IN AND/OR INSTALLATION. COORDINATE WITH OTHER • i , ar s. ❑ TIME CLOCK GFI - GROUND FAULT CIRCUIT INTERRUPTER Y AIR VENT TRADES FOR CONNECTIONS TO EQUIPMENT. - j ;vim 15. WARRANTY THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE WARRANTY SHALL BE FOR A PERIOD OF ONE YEAR AFTER OWNER'S • ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. C PHOTO-CELL GRD - GROUND T PRESSURE-TEMP.TAP ( ) • •• s 7. ALL ELECTRICAL SYSTEM COMPONENTS SHALL BE LISTED OR LABELED BY UNITED LABORATORIES UL OR OTHER RECOGNIZED "4'a �� PRESSURE GAUGE W/PIG TAIL&COCK TESTING FACILITY. 9+ ' 1.,, 16. SUBMIT RECORD DOCUMENTS TO OWNER. DOCUMENTS SHALL INCLUDE ALL ADDENDUM ITEMS,CHANGE ORDERS,ALTERATIONS, RE ROUTINGS, ETC. T❑ TRANSFORMER IAW IN ACCORDANCE WITHt. et ■�'c\ G PANELBOARD OR LOADCENTER IC INTERMEDIATE CROSS CONNECT I THERMOMETER 8. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON si„laNktt 17. SYSTEMS SHALL BE COMPLETE,OPERABLE,AND READY FOR CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER. 4 TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT,OR INSTALLATION METHODS. 18. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF TESTS OF WORK ARE DEFECTIVE, © CONTACTOR IDF INTERMEDIATE DISTRIBUTION FRAME Y VACUUM BREAKER 9. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO ADDITIONAL COST TO OWNER. KY ELECTRIC MOTOR IG ISOLATED GROUND _ EV STRAINER W/BLOW-OFF VALVE THE ARCHITECT AND/OR ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 19. ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. IS METER IR - INFRARED -MAD SHOCK ABSORBER 10. THE CONTRACTOR SHALL PROVIDE APPROPRIATE FIRESTOPPING FOR ALL FIRE RATED ASSEMBLY PENETRATIONS. FIRESTOPPING SYSTEM SHALL BE UL LISTED AND TESTED IN ACCORDANCE WITH ASTM E814 OR ASTM E119 WITH AN F RATING EQUAL TO THE FIRE 20. SUBMIT ALL MECHANICAL DIVISION SHOP DRAWING AND PRODUCT DATA AT ONE TIME. PARTIAL SUBMITTALS WILL BE REJECTED. 0 THERMOSTAT LAN - LOCAL AREA NETWORK s FLOW SWITCH RATING OF PENETRATED ASSEMBLY. 21. SHOP DRAWING SUBMITTALS SHALL STATE CAPACITIES, SIZES, ETC.,OF ALL EQUIPMENT AND SHALL BE CERTIFIED AND INCLUDE COMPUTER BASED PROJECT ATS AUTOMATIC TRANSFER SWITCH MDF MAIN DISTRIBUTION FRAME HORIZONTAL CLEANOUT 11. UPON COMPLETION OF THE PROJECT,THE CONTRACTOR SHALL PROVIDE UPDATED DIRECTORIES FOR ALL PANELBOARDS AND LOAD SPECIFIC SELECTIONS WHERE APPLICABLE. CLEARLY MARK EACH SHOP DRAWING,CATALOG CUT AND/OR SPECIFICATION SHEET TO INDICATE THOSE PRODUCTS lio CIRCUIT HOMERUN (N) - NEW II VERTICAL CLEANOUT CENTERS. DIRECTORIES SHALL BE COMPUTER GENERATED USING WORD PROCESSING OR SPREADSHEET GENERATION SOFTWARE AND FEATURES WHICH ARE INTENDED TO BE FURNISHED. SPECIFICALLY INDICATE ANY DEVIATIONS FROM THE DESIGN INTENT. ENGINEER RESERVES THE RIGHT TO AND INSTALLED UNDER CLEAR PLASTIC COVERS. EACH CIRCUIT SHALL BE IDENTIFIED AS TO ITS SPECIFIC PURPOSE OR USE. THE REQUIRE CORRECTION AT NO COST TO OWNER FOR DEVIATIONS NOT SPECIFICALLY INDICATED IN THE SUBMITTALS. REVIEW AND APPROVAL OF SHOP DRAWINGS CONDUIT RUN NIC - NOT IN CONTRACT Q FLOOR DRAIN IDENTIFICATION SHALL BE SUFFICIENTLY DETAILED TO DISTINGUISH EACH CIRCUIT FROM ALL OTHERS. ROOM NAMES AND NUMBERS SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF FURNISHING EQUIPMENT AND MATERIALS OF PROPER DIMENSION, SIZE,QUANTITY, QUALITY 0 FLOOR SINK SHALL BE AS DIRECTED BY OWNER. AND ALL PERFORMANCE CHARACTERISTICS TO EFFICIENTLY PERFORM THE REQUIREMENTS AND INTENT OF THE CONTRACT DOCUMENTS. SUBMITTAL SHALL BE --- CONDUIT RUN BELOW GRADE NL - NIGHT LIGHT BOUND AND INDEXED IN A NEAT AND ORDERLY MANNER. a ROOF DRAIN 12. WIRING DEVICES SHALL BE SPECIFICATION GRADE, RATED 20 AMPERES FOR LIGHT SWITCHES AND 20 AMPERES FOR DUPLEX -0 CONDUIT UP NTS - NOT TO SCALE RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS SELECTED BY ARCHITECT. EO, 22. FAILURE TO ORDER,OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, CONDUIT DOWN OC - ON CENTER \.0, DECK/ROOF DRAIN ABOVE EQUIPMENT, OR INSTALLATION METHODS. I=1 TEMPERATURE CONTROLLER OR SENSOR 13. ALL NEW JUNCTION BOX COVERS SHALL BE CLEARLY LABELED AND IDENTIFIED WITH THE BRANCH CIRCUIT(S)CONTAINED WITHIN, S SWITCH PA PUBLIC ADDRESS INCLUDING THE SOURCE PANELBOARD NAME, ON THE FACE OF THE JUNCTION BOX COVER. 23. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY,APPEARANCE OR HHB FUNCTION. sT THERMAL OVERLOAD SWITCH REF - REFRIGERATOR HOSE BIBB 14. WIRE SHALL BE COPPER,75 DEGREE CELSIUS RATED FOR GENERAL USE UNLESS INDICATED OTHERWISE ON THE DRAWINGS. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE 24. PROVIDE 4"HIGH CONCRETE EQUIPMENT PADS BENEATH FLOOR MOUNTED MECHANICAL EQUIPMENT, IN ADDITION TO ANY BASE ASSEMBLIES REQUIRED OR SV VARIABLE SPEED SWITCH TTB - TELECOMMUNICATIONS TERMINAL BOARD W H FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT RECOMMENDED BY THE MANUFACTURER. WALL HYDRANT INSTALLATIONS. SK KEY SWITCH TVSS - TRANSIENT VOLTAGE SURGE SUPPRESSOR 25. FIRE STOPPING REQUIREMENT. PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE TVTB - TELEVISION TERMINAL BOARD I STEAM TRAP TEST CHAMBER 15. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS OF FLAMES AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM-E-814. ACCEPTABLE MATERIALS SHALL BE INSULATED THROAT TYPE. MINIMUM CONDUIT SIZE IS 3/4". FOLLOW NEC FOR MAXIMUM NUMBER OF CONDUCTORS PER INCLUDE: DOW CORNING RTV FIRE STOP FOAM FOR BARE PIPE, METAL CONDUIT,AND ELECTRICAL CABLE; 3M FIRE DAM 150 CAULK FOR BARE PIPE, METAL CONDUIT, ONE-LINE DIAGRAM SYMBOLS UG - UNDERGROUND 0 STEAM TRAP: CONDUIT. CONDUIT SHALL BE OF SUFFICIENT SIZE AND CONDUCTOR QUANTITY SHALL BE LIMITED TO ELIMINATE THE NEED TO DERATE AND BUILDING CONSTRUCTION GAPS;3M CP-25 CAULK AND FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, PLASTIC PIPE OR CONDUIT,AND ELECTRICAL FT-FLOAT&THERMOSTATIC CONDUCTORS. METAL CLAD CABLING SHALL NOT BE PERMITTED. CABLE. SUBMIT UL LISTED APPLICATION DATA FOR EACH TYPE OF PENETRATION ENCOUNTERED. -� DISCONNECT SWITCH UNO - UNLESS NOTED OTHERWISE TD-THERMODYNAMIC IB-INVERTED BUCKET 16. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUIVALENT AND SHALL BE IDENTIFIED AT ALL JUNCTION, LO 26. CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE AVAILABLE. ® FUSE V - VOLT TS-THERMOSTATIC PULL,AND TERMINATION POINTS USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT,ORIGINATION, CO (0 BP-BALANCED PRESSURE AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. W 27. SUBMIT A WRITTEN BALANCE REPORT BY A NEBB OR AABC CERTIFIED BALANCING CONTRACTOR. BALANCING PROCEDURES SHALL BE IN ACCORDANCE WITH NEBB 1Z CIRCUIT BREAKER W WATT a CO OR AABC GUIDELINES FOR PROPORTIONAL BALANCE. SUBMIT REPORT ON STANDARD NEBB FORMS OR SUBMIT FORMS FOR REVIEW PRIOR TO BALANCING. CURRENT TRANSFORMER WAN WIDE AREA NETWORK 17. ALL NEW EMERGENCY LUMINAIRES SHALL MEET UL924,AS WELL AS ALL APPLICABLE SECTIONS OF NFPA 101, NEC,AND OSHA MEASUREMENTS SHALL INCLUDE ALL MOTOR AMPERAGE AND VOLTAGE READINGS; MOTOR AND FAN RPMS; STATIC PRESSURE AT INLET AND OUTLET OF ALL ILLUMINATION STANDARDS. C 0 PACKAGED EQUIPMENT, FANS, COILS,AND FILTERS; PITOT TUBE MEASUREMENT OF SUPPLY, EXHAUST, RETURN,AND OUTSIDE AIR MAIN DUCTS,AT MINIMUM -3E POTENTIAL TRANSFORMER WAP - WIRELESS ACCESS POINT PLAN SYMBOLS 18. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS,AND `J OUTSIDE AIR,AND 100%(ECONOMIZER)OUTSIDE AIR;VELOCITY DISTRIBUTION ACROSS THE FACE OF FILTERS;AIR INLET AND OUTLETS;WATER FLOW AT ALL FLOW MEASUREMENT STATIONS; INLET AND OUTLET PRESSURE AT PUMPS WITH FLOW CALCULATED FROM THE PUMP CURVE;WATER FLOW,TEMPERATURE DROP,AND e METER WLAN - WIRELESS LOCAL AREA NETWORK ` CONTROL PANEL/RADIANT MANIFOLD INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH I 0_ Q PRESSURE DROP AT ALL COILS. EQUIPMENT SUPPLIED. �/ Q VOLT-METER WP - WEATHERPROOF ®O CARBON DIOXIDE SENSOR 28. SUPPORT PIPE WITH ROD AND CLEVIS, RING HANGERS,TRAPEZE,OR CLAMPS. NO PIPE TAPE OR STRAPPING ALLOWED. ALL HANGERS SHALL BE SIZED FOR OD OF Q AMP METER XP EXPLOSIONPROOF 9CARBON MONOXIDE SENSOR 19. THE FINAL SIX(6)FEET OF ALL CONNECTIONS TO MOTORS,TRANSFORMERS,AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL-TITE N O INSULATION, IF ANY. PROTECT INSULATED LINES WITH 20 GA SHEET METAL SHIELDS AND PROVIDE CALCIUM SILICATE INSULATION INSERTS FOR ALL INSULATED FLEX(OR EQUIVALENT)WITH APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR LLJ PIPING. MAINTAIN VAPOR BARRIER ON ALL COLD LINES. ISOLATE BARE COPPER LINES FROM HANGERS WITH VIBRASORB OR EQUIVALENT,COPPER COATED SPD SURGE PROTECTION DEVICE +18" - MOUNTING HEIGHT TO CENTERLINE OF Q HUMIDISTAT MECHANICAL EQUIPMENT. 2 LLI O HANGERS ARE NOT SUFFICIENT,WRAPPING PIPE WITH TAPE NOT ACCEPTABLE. DEVICE ABOVE FINISH FLOOR(VERIFY W/ARCH ELEVS) S REMOTE TEMPERATURE SENSOR J igi SELECTOR SWITCH 0 20. SYSTEMS SHALL BE COMPLETE,OPERABLE,AND READY FOR CONTINUOUS OPERATION. LUMINAIRES,SWITCHES, RECEPTACLES, \ O 0 29. COPPER PIPE VALVES AND SPECIALTIES 0 THERMOSTAT MOTORS, ETC.SHALL BE CONNECTED AND OPERABLE. / GF GROUND FAULT PROTECTION \ m J A. GATE VALVES-BRONZE,CLASS 125,200 LB.W.O.G. sT SP DUCT STATIC PRESSURE SENSOR 21. CONTRACTOR SHALL GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER / B. BALL VALVES-BRONZE, CLASS 125,600 LB.W.O.G. SHUNT TRIP NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST C. CHECK VALVES-BRONZE,CLASS 125,200 LB.W.O.G. ROOM PRESSURE SENSOR TO THE OWNER. > D. BALANCING VALVES-125 PSI W.P. FOR 250 DEGREE FAHRENHEIT SERVICE TIGHT SHUTOFF,TOUR AND ANDERSON STA,ARMSTRONG CBV, GERAND, OR NORMALLY OPEN CONTACT TR EMERGENCY POWER OFF SWITCH FLOWSET, B&G CIRCUIT SETTER. NORMALLY CLOSED CONTACTP 22. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED e E. DIRECT UNIONS: FURNISH AND INSTALL A DIELECTRIC UNION AT EACH CONNECTION BETWEEN DISSIMILAR METALS. PLUMBING/HVAC RISER UNDER THIS SECTION OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. GROUND DIAGRAM CONTINUATION REFERENCE 30. AS PIPING:SCHEDULE 40 BLACK STEEL PIPE, 150 LB. MALLEABLE IRON SCREWED FITTINGS ON ABOVE GROUND PIPE,WELDED FITTINGS WITH ALL PIPING COATED 23. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE,CONTRACTOR SHALL MAKE AND WRAPPED ON BURIED PIPE. Ca COLD WATER GROUND CONNECTION = SECTION CUT LETTER/SHEET SHOWN ON NECESSARY CORRECTIONS AT NO COST TO THE OWNER. 31. GAS VALVES: NON-LUBRICATED BALL STYLE VALVE WITH RESILIENT SEATS,AND ADJUSTABLE GLAND PACKING NUT,AGA AND UL LISTED FOR NATURAL GAS SERVICE. I BUILDING STEEL GROUND CONNECTION 619 POINT OF DISCONNECTION 24. CONDUCTOR COLOR CODING SHALL BE CONSISTENT THROUGHOUT THE ENTIRE PROJECT. - 9 POINT OF NEW CONNECTION 25. LOAD CENTERS SHALL NOT BE USED IN LIEU OF PANELBOARDS UNLESS SPECIFICALLY INDICATED ON DRAWINGS OR APPROVED BY 32. FILL HEATING WATER SYSTEM WITH 20% PROPYLENE GLYCOL/WATER SOLUTION AND FILL SNOWMELT SYSTEM WITH 50%PROPYLENE GLYCOL/WATER SOLUTION. ^] IL ACCESS PANEL ENGINEER OF RECORD. BUS BARS SHALL BE ALUMINUM AND LUGS SHALL BE ALUMINUM CAPABLE OF LANDING COPPER OR ALUMINUM 33. GRADE AND VALVE ALL HEATING, CHILLED AND SNOWMELT WATER PIPING WITH 3/4"HOSE END VALVES TO PERMIT COMPLETE DRAINAGE OF THE SYSTEM. VENT ALL CONDUCTORS. HIGH POINTS IN EQUIPMENT ROOMS AS NECESSARY WITH AUTOMATIC AIR VENTS PIPED TO CONVENIENT DRAIN. ALL HIGH POINTS IN SYSTEM OUTSIDE OF SNOWMELT MANIFOLD EQUIPMENT ROOMS WITH COMBINATION AUTOMATIC/MANUAL AIR VENTS AS REQUIRED TO RELIEVE AIR IN THE SYSTEM. 34. MATERIALS; HYDRONIC PIPING A. ABOVE GRADE, UP THROUGH 2-1/2": SCHEDULE 40 STEEL PIPE WITH MALLEABLE IRON THREADED FITTINGS,OR TYPE"L"COPPER TUBE WITH WROUGHT COPPER FITTINGS AND 95-5 NO LEAD SOLDER. O B. ABOVE GRADE,3"AND LARGER: SCHEDULE 40 STEEL PIPE WITH CAST IRON OR STEEL WELDING FITTINGS. 0 O 35. DRAIN AND RECEPTOR PIPING FOR COMBUSTION CONDENSATE--NOT BURIED--TYPE: SCHEDULE 40 SOLID-WALL PVC, PVC FITTINGS,AND PVC CEMENT. PROVIDE w NEUTRALIZATION SYSTEMS AS RECOMMENDED BY COMBUSTION APPLIANCE MANUFACTURER. 2 o o 36. INDOOR PIPING INSULATION-INSULATE ALL NEW HEATING WATER PIPING WITH UL APPROVED,WHITE,ALL SERVICE, MINERAL FIBER, SNAP-ON, PIPE INSULATION. rn INSULATE FITTINGS WITH MINERAL FIBER BLANKET INSULATION AND PRE-MOLDED PVC COVERS. ALL MATERIALS SHALL HAVE A SMOKE DEVELOPED RATING co coOF 50 OR LESS AND A FLAME SPREAD RATING OF 25 OR LESS. PROVIDE CALCIUM SILICATE THERMAL INSERT AT HANGERS AND SUPPORTS. INSULATION SHALL PASS Lu UNINTERRUPTED THROUGH HANGERS. VAPOR BARRIERS SHALL BE CONTINUOUS,AND SEALED WITH"NON-BREATHING"VAPOR BARRIER MASTIC ON PIPING Current Issue: O OPERATING AT TEMPERATURES BELOW AMBIENT. ALL RAW EDGES OF INSULATION SHALL BE NEATLY TRIMMED AND SEALED WITH MASTIC. Q CC O A. INSULATION THICKNESS BELOW BASED ON INSULATION CONDUCTIVITY VALUE NOT EXCEEDING 0.27 BTU*IN/(HR*FT^2*°F): PERMIT SET D CC W 1) HEATING WATER(LESS THAN 200°F)-NPS 1.25 AND LESS, 1.5"THICK; NPS 1.5 AND GREATER, 2"THICK. RUNOUTS WITHIN 4 FEET OF TERMINAL AND 1"PIPE J DIAMETER OR LESS, 1"THICK. 00 37. IDENTIFICATION: LABEL ALL NEW PIPING AND EQUIPMENT. PROVIDE FULL BAND OR STRIP TYPE MARKERS AND FLOW ARROWS ON PIPING. PROVIDE ENGRAVED Issued: co PLASTIC VALVE TAGS WITH VALVE NUMBER AND ATTACH WITH STANDARD CHAIN OR S-HOOKS. PROVIDE ENGRAVED PLASTIC SIGN ON OR NEAR SPECIFIED PERMIT SET 09.23.2016 a EQUIPMENT. 2 0 2 > 0 Z Q CC 0 0 Q 0 w 0 1 w U) 0 Z H J D U) Z 0 0 J J a 0 Z 0 I 0 > Sheet Title: MECHANICAL / 03 ELECTRICAL co COVER SHEET I- 0 w O r d Date: 09.23.2016 0 Designed: DAL U) Reviewed: DAL Project No: 8739.00 PH-002 2 O Sheet No: ti co O ME- 1 . 0 ,_N N Scale: As Shown