HomeMy WebLinkAboutE17-0016_E1.0 plans approved.pdf 10 OF,cr i i i Miti% ecIS P PANEL LP-2 AT TRANSIT OFFICE ELEC PANEL SP-3 AT TRANSIT OFFICE ELEC PANEL SP-4 AT TRANSIT OFFICE ELEC PANEL SP-5 AT LA CATINA lanol PROJECT:VAIL VILLAGE PARKING GARAGE ENGINEER: SOH PROJECT:VAIL VILLAGE PARKING GARAGE ENGINEER: SOH PROJECT:VAIL VILLAGE PARKING GARAGE ENGINEER: SOH PROJECT:VAIL VILLAGE PARKING GARAGE ENGINEER: SOH 06/22/17 PROJECT*16080 VOLTAGE: 277/480V,3P,4W PROJECT#:16080 VOLTAGE: 120/208V,3P,4W PROJECT#:16080 VOLTAGE: 120/208V,3P,4W PROJECT#:16080 VOLTAGE: 120/208V,3P,4W MOUNTING:SURFACE MAINS: 200 A MLO MOUNTING:EXISTING RECESSED MAINS: *150A MCB MOUNTING:EXISTING RECESSED MAINS: 250A MCB MOUNTING:EXISTING RECESSED MAINS: 150A MLO TYPE:SQUARED AIC: 14K AIC TYPE:EXISTING SQUARED AIC: 1 DK TYPE:EXISTING SQUARED AIC: 10K TYPE:EXISTING SQUARED AIC: 10K PHASE PHASE PHASE PHASE PHASE PHASE PHASE PHASE_ DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION 4TH FL INT WALL MOUNTS 1000 20 1 1 2 1 20 1000 S&W RECESS WALL LTS TIME CLOCK&XMAS LIGHTS 1000 20 1 1 2 1 20 1000 AIRPORT SHUTTLE RECEPT PANEL SP5 11333 150 3 1 2 1 20 1000 TRAINING ROOM LTS KO-3 COMPRESSOR 1000 20 2 1 2 1 20 1000 HOOD RECESSED LIGHTS • WEST RECESS CANS 1000 20 1 3 4 1 20 1000 4TH LEVEL WING WALL CANS TIME CLOCK&XMAS LIGHTS 1000 20 1-3 4 1 20 1000 GRAYHOUND RECEPT RESTAURANT PANEL _ 11333 3 __ 4 1 20 1000 TRAINING ROOM LTS 1000 3 4 1 20 1000 S-13 DINING RECEPT EAST WALL MOUNT&CANS 1000 20 1 5 6 1 20 1000 N&E RECESS WALL LTS AIRPORT SHUTTLE RECEPT 1000 20 1 5 6 1 20 1000 4TH LVL VENDING MACH 6 SPACE CIRCUIT BREAKER 11333 5 6 1D 20 0 UNIDENTIFIED K-25 LIQUID WARMER 1000 20 2 5 6 1 20 1000 SO-1 BATHROOM LOCKER RM LTS 1000 20 1 7 8 1 20 1000 REGIONAL TRANS LTS LOCKER RM EXHAUST 500 20 1 7 8 1 20 1000 EAST AIR CURTAIN 07 8 1 20 1000 CONFERENCE OFFICE 1000 7 8 1 20 1000 KO-1&2 WALK IN COOLER LEVEL ENTRY LIGHTS 1000 20 1 9 10 1 20 1000 AIRPORT SHUTTLE LTS CHARTER SPORTS RECEPT 1000 20 1 9 10 1 20 1000 WEST AIR CURTAIN " 0 9 10 2 20 750 ROOF HEAT TAPE KO-4 FREEZER _ 1000 20 2 9 10 1 20 1000 39-35 KITCHEN RECEPT OFFICE LIGHTS 1000 20 1 11 12 1 20 1000 GREYHOUND&CME LTS NORTH HANDICAP DOOR 800 _ 20 1 11 12 1 20 1000 NORTH AIR CURTAIN " 0 11 12 T 750 1000 11 12 1 20 1000 41 KITCHEN RECEPT Ci) O ELEC RM LIGHTS 1000 20 1 13 14 1 20 1000 LEVEL 4 EM LTS WEST HANDICAP DOOR 800 20 1 13 14 1 20 1000 ELECT RM RECEPT COFFEE CART 3750 • 50 2 13 14 1 20 500 EXHAUST FAN DISPOSAL 1000_ 20 2 _ 13 14 1 20 1000 K-15 DISH WASHER ci) N SPACE 0 15 16 1 20 1000 LEVEL 3 EM LTS TV RECEPTACLE 500 20 1 15 16 1 20 1000 ELECTRM RECEPT 3750 _ 15 16 1 20 1000 SUPERVISOR OFFICE 1000 15 16 1 20 _ 1000 BACK WALL RECEPT a" U 0 SPACE 0 17 18 1 20 1000 RESTAURANT LIGHTS UNIDENTIFIED 1000 20 1 17 18 1 20 500 LOCKERS EXHAUST FAN COFFEE CART 2000 30 2 17 18 1 20 180 MENS GFI K-27 TOASTER OVEN 1000 20 2 17 18 1 20 1000 SO-5 BAG IN BOX RECEPT +-• • 5 O O SPACE 0 19 20 0 SPACE UNIDENTIFIED 1000 20 1 19 20 1 20 500 LV TRANSFORMER 2000 19 20 1 20 500 EXHAUST FAN 1000 19 20 1 20 1000 K28&39 MW,REF TOP = 0 •- -O SPACE 0 — 21 22 0 SPACE FIRE DAMPER 100 20 1 21 22 1 20 1000 PHONE RECEPTACLES YOGURT RECEPTACLES#3 _ 1000 20 2 21 22 1 20 1000 VENDING MACHINE K-36 HOOD EXHAUST FAN 1000 20 3 21 22 1 20 1000 KO-4 ( 2 E C C a) 0 SPACE 0 23 24 0 SPACE AIR CURTAIR DOOR 1000 20 1 23 24 1 20 1000 TRAINING ROOM 1000 23 24 1 20 1000 UNIDENTIFIED " 1000 23 24 1 20 1000 S-11 KITCHEN RECEPT O O TD PANEL SP-4 30887 100 3 25 26 3 70 13233 PANEL SP-3 HEAT TAPE 750 20 2 25 26 1 20 1000 JANITORS RECEPTACLES 1 ROOF HEAT TAPE 750 20 2 25 26 1 20 1000 UNIDENTIFIED II _ 1000 25 26 1 20 1000 COUNTER TOP RECEPT 0 d(-) N 30887 27 28 13233 750 __27 28 1 20 1000 HVAC TRANSFORMER 750 27 28 1D 20 0 UNIDENTIFIED HOOD RETURN AIR 1000 20 3 27 28 1 20 1000 COUNTER TOP RECEPT O �L E " 30887 29 30 13233 ATM MACHINE 1000 20 1 29 30 1 20 1000 CABINET UNIT HEATER MENS/WOMENS HAND DRYER 0 20 1D 29 30 3 100 6167 PANEL SP-6 1000 29 30 1 20 1000 CASH REGESTER __4? o ao 0 20 1 31 32 1 20 15000 BREAK ROOM HEATER 1000 20 2 31 32 1 20 1000 TIME CLOCK UNIDENTIFIED 800 15 1 31 32 6167 " 1000 31 32 0 SPACE C -0 > .1- V SPACE 0 33 34 15000 ,, 1000 33 34 1 20 1000 UNIDENTIFIED UNIDENTIFIED 0 20 10 33 34 6167 " COFFEE MAKER 1500 30 2 33 34 0 SPACE .LCD 15) r--- SPACE 0 _ 35 36 15000 " HEAT TAPE 750 20 2 35 36 1 20 _ 1000 UNIDENTIFIED WATER HEATER 2250 30 2 35 36 2 20 500 SPRINKLER HEAT TAPE 1500 35 36 0 SPACE a) . 0 N r- SPACE 0 - 37 38 0 SPACE 750 37 38 2 30 1500 BREAK RM WATER HEATER 2250 37 38 500 SPACE 0 37 38 0 SPACE C oo Q O O a) SPACE 0 39 40 0 SPACE ELECT RM WATER HEATER 1750 30 2 39 40 1500 UNIDENTIFIED 0 20 10 39 40 2 20 500 SPRINKLER HEAT TAPE SPACE 0 39 40 0 SPACE � ) I-W c (a SPACE 0 41 42 0 SPACE 1750 41 42 1 20 500 3RD DOOR CLOSURE LADIES ROOM GPI 180 20 1 41 42 500 " SPACE 0 41 42 0 SPACE LOAD CALCULATION SUMMARY CONTRACTOR TO REPLACE EXISTING PANEL WITH NEW AS SCHEDULE. LOAD CALCULATION SUMMARY *CHANGE OUT EXISTING MAIN CIRCUIT BREAKER WITH 150A/3P LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY L.I. a) -ILLJ 05 a) CONFIRM ALL LOADS AND CIRCUITS AT THIS PANEL. CD W -C CO N CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: = 73 ~ 0.96 0.92 0.96 0.96 -I-' U N = CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS C CCI Ci) LIGHTING/CONTINUOUS 27600 33 34500 42 LIGHTING/CONTINUOUS 2000 6 2500 7 LIGHTING/CONTINUOUS 4600 13 5750 16 LIGHTING/CONTINUOUS 1000 3 1250 3 +0 _c 0 D RECEPTACLES 62760 76 36380 44 RECEPTACLES 19200 53 14600 40 RECEPTACLES 28560 79 19280 53 RECEPTACLES 8000 22 8000 22N O r MECHANICAL 43000 52 47875 58 MECHANICAL 18500 51 19375 54 MECHANICAL 19500 54 21500 60 MECHANICAL 8000 22 8750 24 0 2 Q co KITCHEN 60000 72 39000 47 KITCHEN 0 0 0 0 KITCHEN 40000 111 26000 72 KITCHEN 17000 47 17000 47 Q TOTAL 193360 233 157755 190 TOTAL 39700 110 36475 101 TOTAL 92660 257 72530 201 TOTAL 34000 94 35000 97 PANEL SP-6 AT TRANSIT OFFICE ELEC PANEL SP-7 ,,.`.." ""••••.. PROJECT:VAIL VILLAGE PARKING GARAGE ENGINEER: SOH PROJECT:VAIL VILLAGE PARKING GARAGE ENGINEER: SOH .�•''i�¢QO REG/� +,+_ PROJECT#:16080 VOLTAGE: 1201208V,3P,4W PROJECT#:16080 VOLTAGE: 120/208V.3P.4W �0 0 O H MOUNTING:EXISTING RECESSED MANS: 100 A MLO * C-- `y'Lr_ 'p,= MOUNTING: RECESSED OR SURFACE MAINS: 150A MCB TYPE:EXISTING SQUARE D AIC: 10K TYPE:SQUARE 0 NQOD AIC: 10K . °r _ , PHASE PHIASE PHASE PHASE =� A ■ri • II ' s DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION EXISTING SI LE PHA PANEL AT ELECTRICAL ROOM, RELABEL WITH PLAQUE READING "PANEL SP-6" 4 �" GFI KITCHEN RECEPT 800 20 1 1 2 1 20 800 GFI KITCHEN RECEPT SPARE 0 20 1 1 2 1 20 0 SPARE '' EL. PANEL G ,• SP-5 AT LA TINA SP-6 = T ‘.4-�a DISHWASHER 1000 20 1. 3 4 1 20 800 _ KITCHEN LIGHTS - - ‘,10 SPARE 0 20 1 3 4 1 20 0 SPARE :���1/4)Se L-E MECH TRANSFORMER 1000 20 1 5 6 1 20 1000 DISPOSAL SPARE 0 20 1 5 6 1 20 0 SPARE NEW WORK IS CLOUDED, REST ' WINDOW 800 20 1 7 8 1 20 800 GFI KITCHEN RECEPT 1 SPARE 0 20 1 7 8 1 20 0 SPARE r''•••., ,+r."``' - • IS EXISTING. REPLACE PANEL CAMERA 800 20 1 9 10 2 30 1500 YOGURT RECEPT#2 SPARE 0 20 1 9 10 1 20 0 SPARE REPLACE EXISTING PANEL EM-2 AS LP2, SP 3 TRANSFORMER, YOGURT 1000 20 2 11 12 1500 SPARE - 0 20 1 11 12 1 20 _ 0 SPARE RECEPTACLES#4 1000 13 14 2 15 750 YOGURT RECEPT#1 SPARE 0 20 ' 1 13 14 1 20 0 SPARE SCHEDULED. MOVE EXISTING BUS MAIN CIRCUIT BREAKER FOR PANEL PANEL PANEL ECO RECEPTACLES 800 20 1 15 16 750 SPARE 0 20 1 15 16 0 SPACE TERMINAL AHU-1, BOILER#4A&#4B, PUMPS SP-3 AND ASSOCIATED SP-3 SP-4 SP-7 ECO RECEPTACLES _ 800 20 1 17 18 1 20 _ 1000 ECO APPLIANCE RECEPT SPARE 0 20 1 17 18 0 SPACE #3 &4 CIRCUITS AND BOILER CONTROL FEEDERS FOR PANEL SP-3 � _•i T UNIDENTIFIED 800 20 1 19 20 1 20 800 TRANSIT TRACK LTG ESTIMATED MECHANICAL 1667 3 19 2D 0 SPACE CIRCUITS TO PANELS EM-1 & EMCCA-120V i 150/3 .14#1/OCU 1#6 CUGND)2"C SPACE 0 21 22 0 SPACE 1667 21 22 0 SPACE PER PANEL SCHEDULES SHEET E1.1 ^ n SPACE 0 23 24 0 SPACE 1667 23 24 0 SPACE 100/3 1 AT EXISTING BOILER#4A&#4B, PUMPS#3 0 ESTIMATED RECEPTACLE 5000 3 25 26 0 SPACE PANEL 150/3 250/3 150/3 " - 5000 , - 27 28 - 0 SPACE &4 PROVIDE 30/3 SERVICE DISCONNECT EM-2 \._-(4#1 CU - 1 #8 CU GND) "C 5000 29 30 0 SPACE SWITCHES FOR EQUIPMENT AS REQUIRED BY CODE. PROVIDE IDENTIFICATION OF - <10K Al <10K AIC ESTIMATED KITCHEN 6667 3 31 32 0 SPACE (4#3/0 AL, #2 AL G)2"C (4#3/0 AL, #2 AL G)2°c 6667 33 34 0 SPACE DISCONNECTS WITH PLAQUES TO READ 6667 35 36 0 _ SPACE "BOILER#4A", "BOILER#4B" ETC. (3#4 CU, #8 CU G) 1-1/2"C] ESTIMATED LIGHTING 1667 3 37 38 0 SPACE LOCATE DISCONNECTS IN FIELD REVIEW __ 45 KVA __ 75 KVA = 45 KVA H N" 1667 39 40 0 _ SPACE WITH OWNER PRIOR TO ROUGH-IN. ARI 1667 41 42 _ 0 SPACE 480/ 480V/ - 480/ - Z 1.0 CHA 120/208V 120/20: 120/208V CD - <14K AIC WEST P2 3P,4W 3P,4 3P,4W CO LOAD CALCULATION SUMMARY • LOAD CALCULATION SUMMARY REVIEW PANEL SIZING LOCATION BEFORE LOBBY/CATINA REMODEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL NEL (3#4 CU,#8 CU G) 1-1/2"C] Z r LOCATION TO BE DETERMINED GEN EMCCA PP2 EM-1 SP1 HP1 LP1 UC-1 XFMR LVL 2 2 l..I_J CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: 0.99 0.98 60/2 (1- n O CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS __r\ 100/3 70/32 LIGHTING/CONTINUOUS 1600 4 2000 6 LIGHTING/CONTINUOUS 5000 14 6250 17k-(3#6 CU, #8 CU) Q RECEPTACLES 6400 18 6400 18 RECEPTACLES 15000 42 12500 35 3/4" C 125/2 100/3 Q MECHANICAL 1000 3 1250 3 MECHANICAL 5000 14 6250 17 t nI2 KITCHEN 9500 26 9500 26 KTHEN 20000 55 20000 55 70/3 TOTAL 18500 51 19150 53 TOTAL 45000 125 45000 125 .,<14K AIC <10K AIC LJ_J 0 CC REPLACE EXISTING PANEL LP2 PER PAN L SCHEDULE 25 KVA _I_= 1Z < J 480V- _ PANEL 120/208V>1 P 0 3W MDP r PANEL W < v, EMCC LOCATE ENGINE-GENERATOR - 200/3 J ANNUNCIATOR IN011 EMCCA-36 EG BUS SUPERVISOR'S OFFICE. 200/3 LI_i Q ANNUN CONNECT TO EG-1. r PANEL PANEL PANEL PANEL 70/2 r 200/3 LP-3 HP-1 MMC2 LP-4I2 > _J THESE LOADS FED 70/3 200/3 FROM PANEL GEN -200/3 <14K AIC .,f J 401/3 _ E G 1 EG BATT HEATER CHARGER ~200/3 <19K AIC 4#250 MCM AL)2-1/2"C N 450 KW, 277/480 3P 4W STANDBY �<17K AIC <19K AIC BONDING JUMPER VERIFY FEEDER AND • DIESEL GENERATOR, FOR AN C 2[(4#500 MCM CU)4"C] FUSES PRIOR TO START G ALTITUDE OF 8150FT. GENERATOR , C TS UP OF WORK TO INCLUDE WEATHERPROOF E G800/3 -2[(4#500 MCM CU)4"C] 800/3 - ENCLOSURE, DAY TANK, CRITICAL AEC PROJECT #: 16080 SILENCER EXHAUST MUFFLER,AND (#3/0 CU G)3/4"C TT VIBRATION ISOLATORS. 1 2[(4#500 MCM CU)4"C] DATE: ISSUE: HOLY CROSS METER#93458 GENERATOR NOTES UTILITY HIGHEST DEMAND JANUARY 2015 11/8/16 PROGRESS 290 KW-350 AMPS TRANSFORMER M <19KAIC <19KAIC 11/16/16 PERMIT INCOMING GAS. • — — — — — — — — — — — — — — — — — — 55_ SERVICE PIPE 1. CONTRACTOR TO PROVIDE CONCRETE PAD TO MEET PAD MOUNTED #6 TO GENERATOR MANUFACTURER'S REQUIREMENTS. (3)800A (3)800A (3)200A (3)200A (3)200A (3)200A TELEPHONE/TV FUSES FUSES FRN-R FRN-R FRN-R FRN-R INCOMING WATER. t MANUFACTURER TO INCLUDE PAD INFORMATION ON THEIR 800/3 800/3 200/3 200/3 200/3 200/3 SERVICE PIPE WATER 1 CONCRETE- ENCASED SHOP DRAWINGS. INITIAL ESTIMATE FOR THE PAD, WITH A 6" LIP xT99,500 AIC 78,500 AICX J I 1 [ METER ELECTRODE ON ALL SIDES, 98"W X 200"L X 12"DEPTH USING CONCRETE EXISTING I I I DENSITY OF 145 LBS/F3. Drawn By: Checked By: C-BUILDING STEEL 2. WITH SHOP DRAWINGS FROM GENERATOR MANUFACTURER STAKE SOH AEC OUT NEW GENERATOR PAD TO REPLACE EXISTING GENERATOR (SAME LOCATION). REVIEW HEIGHT, FUELING ARRANGEMENTS, - - - - - - - - - - - - - - - - - - - - -(3)3/4"x10' DRIVEN WHERE THE EXHAUST IS TERMINATED, IF TREES NEED TO BEMAIN DISTRIBUTION STRI B UTI ON CENTER "MDC" /I ----- GROUND RODS REMOVED OR TRIMMED,ACCESS DOORS ARE ALL CLEAR,ETC. ELECTRICAL IF REQUIRED PROVIDE SITE MEETING WITH OWNER AND ELECTRICAL ENGINEER 2000A 277/480V 3P 4W BY LOCAL AHJ TO REVIEW TWO CONFIGURATIONS OF THE GENERATOR, ONE WITH 1 7 7 THE GENERATOR ORIENTED NORTH/SOUTH AND THE SECOND WITH 42kAIC ONE-LINE THE GENERATOR ORIENTED EAST WEST. SERVICE GROUNDING DETAIL ELECTRICAL ONE-LINE DIAGRAM DIAGRAM NO SCALE NO SCALE NOTE: 1. PROVIDE#3/0 CU CONDUCTORS TO ALL GROUNDING ELECTRODES. NOTE: 1. PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED AT ONE-LINE, 2. CONFIRM BUILDING GROUNDING SYSTEM IS UP TO DATE NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION ACCEPTABLE, AND TO CURRENT CODES AS SHOWN PER THIS DETAIL. SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP DRAWING REVIEW. SCALE: NONE PROGRESS DRAWINGS - NOT FOR CONSTRUCTION 1 of E1 . O __ (ID-COPYRIGHT 2014 ARCHITECTURAL ENGINEERING CONSULTANTS INC,