HomeMy WebLinkAboutA17-0031_Cut Sheets Unit 370_1498767900.pdf (4 CIF 164 MacurcoTM mac 11, ) Carbon Monoxide Detector �A� Ar�, Vail Fire&Emergency Services 06/29/17 cm - El 4 • . . •0• i•a ••• r, , ._,. . .... . ....:.. iiiiiiimili "Ill ', L 2i SIGNALING el For use with alarm control panels LISTED Carbon Monoxide Detection The CM-E1 is a low voltage detector of Carbon Monoxide (CO). The CM–E1 is designed for connection to UL Listed Fire Alarm/Burglary Control Panels.Alarm control panels that work on 12 or 24 VDC can provide battery backup to the CM-E1 detectors. This carbon monoxide detector is designed to detect CO gas from ANY source of combustion. It is NOT designed to detect smoke, fire or any other gas. Features • Listed to UL standard 2075 for the Standard For Safety for Gas and Vapor Detector and Sensors • Tested to UL 2075 using UL 2034 Sensitivity limits for carbon monoxide gas • California State Fire Marshal Listed • Surface mounts to a wall using the supplied enclosure rear housing • Flush mounts in a 2 x 4 (1-3/4 inch deep minimum) single gang switch, — - or handy electrical box • Small, low profile, attractive unit in a white plastic case AE R I O N ICS • Detector alarms at multiple levels of exposure to carbon monoxide based on time weighted averages of the gas present .------ ��f • Test & Reset switch conducts internal tests and actuates alarm relay • 10 year electrochemical sensor • N.O. or N.C. SPST Alarm Relay and N.C. SPST Trouble relay to connect to Alarm Control Panels • Buzzer: Produces repeating loud tone bursts during alarm, and chirps if sensor trouble is found Manufactured by Aerionics, Inc. Sioux Falls, SD—Phone: 1-877-367-7891 —Email: info@aerionicsinc.com —www.macurco.com 0(4 CIF 164 z 111. ..''.,. CM-E1 Specifications _ .11 P7 • Voltage: 9-32 VDC 55. ii • Current (normal I alarm): 15mA/ 35mA @ 9-32V , . •, O- jq�J' ' • Size: 3-1/8 X 5-1/8 X 1-3/4 inch (7.94 x 13.02 x 4.45 cm) r k i }Vail Fire&Emergency Services { 106/29/17 •Alarm Relay: SPST, 100mA, 40VDC .11 ple • Trouble Relay: SPST, 100mA, 40VDC i I 1°a' • Buzzer Rating: 85 dBA at 10 Feet - v • Shipping Weight: One pound L J • Operating Temp. Range: 40°F (4.4°C) to 100°F (37.8°C) J •Alarm Setting: Per UL 2034 • Color: White • Designed for use with a UL Listed Fire Alarm/Burglary Control Panel Installation With the CM-E1 faceplate mounted on the enclosure's rear-housing the unit can be surface mounted on a wall. A thin mid-plate enclosure component is also supplied with the CM-E1 to mount the CM-E1 on a 2 x 4 inch (5.08cm x 10.16 cm) switch box - single-gang or "handy", provided by the installer. Location There are two usual sources of CO - defective heat sources (furnaces or wood burning stoves) and automobiles running in adjoining garages. The CM-E1 can detect CO from these sources, as well as any other sources of CO. For best operation, mount a CM-E1 in the hallway near each bedroom or office area. In addition, another CM-E1 may be mounted just inside the door from the adjoining garage. Consider placing another detector in a bedroom or office that is adjacent to a furnace room. The detector may be installed on either a ceiling or a wall. If installed on a peaked, gabled, or sloped ceiling, it should be located about 3 feet (1 meter) from the highest point. The unit can be placed vertically or horizontally on a wall, so the information on the front of the CM-E1 can be read in a normal manner (not upside down). Do NOT mount the CM-E1 in a corner. Use the same spacing as for smoke detectors - 30 foot (9 meters) centers, 900 sq. feet (84 sq. meters) per detector. TYPICAL CONNECTION OF TWO CM-E1 TO AN ALARM CONTROL PANEL TYPICAL COVERAGE 900 SQUARE FEET UL Listed Alarm Control Panel I _ CM-E1 I CM-E1 I Blue Blue N.O.initiating ALARM _ S Yellow ALARM = I Yellow CIICUIt ALARM • ALARM • m o Battery-backed 12 or 24 Gray Gray VDC Power Supply.Fuse ® COMMON COMMON or current limit at 0.2. A for TROUBLE Green TROUBLE Green each CM E1 /l/ 0 Black(-) ._ Black(-) ® ®GND GND GND PWR 0-- PWR 10-- Made in the U.S.A.with US and imported materials GAS DETECTION ©Aerionics 2015.All rights reserved. I ` Macurco is a trademark of Aerionics,Inc. Made in the USA .."4/e. zwlige IA Pn SYSTEMIf b �� SENSOR ilio])10'i -8Emergen y Services 1 r- r r 1 Selectable-Output : - Horns, Strobes, and I 1. I; I Horn Strobes v . 4 . N.i, • SpectrAlert®Advance selectable-output horns,strobes, -s N #.' and horn strobes are rich with features guaranteed to p� cut installation times and maximize profits. SPECTRIert 7 A N Features The SpectrAlert Advance series offers the most versatile and •Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting •Tamper resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance can •Automatic selection of 12-or 24-volt operation at 15 and 15/75 meet virtually any application requirement. candela •Field-selectable candela settings on wall and ceiling units:15,15/75, Like the entire SpectrAlert Advance product line,horns,strobes, 30,75,95,110,115,135,150,177,and 185 and horn strobes include a variety of features that increase their •Horn rated at 88+dBA at 16 volts application versatility while simplifying installation.All devices •Rotary switch for horn tone and three volume selections feature plug-in designs with minimal intrusion into the back box,which make installations fast and foolproof while virtually •Universal mounting plate for wall and ceiling units eliminating costly and time-consuming ground faults.Furthermore, •Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed,protecting devices •Electrically compatible with existing SpectrAlert products from damage. •Compatible with MDL sync module In addition,field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING O O. MEA LISTED APPROVED approved 7 (idstrobes) 7125-1653188125-1653:186(hornnoor strobes, 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) 55512(strobes) 7135-1653:189(horns,chimes) 1:\Z41;AFILAP/e.ii —11111 SpectrAlert Advance Specifications Architect/Engineer Specifications b 0 55 General CO] SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gan. box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting cgiijpgii@c,Emergency Services wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,w&SA2gtegiwith the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9"L x 5.0"W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS,TRCW-HS) 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-007 ..1/4.4..,„. tra,.,,,, UL Current Draw Data hiF tilL UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 1 cryt.W. t Candela DC FWR DC FWR Sound Pattern dB DC FWR DC Standard 15 123 128 66 71 Temporal High 57 55ilFire&fnergencyServices Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58f29/17 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. A05-0395-007 olti OF go '1117'Mil:, SpectrAlert Advance Dimensions 4.7" 2.5" �� 6.8" ma�.yy 4f1} il�i____'_�•ili Dia. 9 '} ice ' �, ), 2.5" Vail Fire&Emergency Services 01 ��— �i, 1 06/29/17 --.iiirk- Wall-mount horn strobes Ceiling-mount horn strobes 7.1" 14-2.25�I 5.05=11_2.23.1 \\Dia. I C I I 7O O o 0 Q \ r oo0oo INM \ ( 5.98" c ( ' •� � a 0 00000 . Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Strobes P2R*t 2-Wire Horn Strobe,Standard cdt,Red SCR Strobe,Standard cd,Red P2RH* 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red P2W* 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White P2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White P4R* 4-Wire Horn Strobe,Standard cd,Red Horns P4RH 4-Wire Horn Strobe,High cd,Red HR Horn,Red P4W 4-Wire Horn Strobe,Standard cd,White HW Horn,White Wall Strobes Accessories SR*t Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red SRH*t Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White SW* Strobe,Standard cd,White BBSC-2 Back Box Skirt,Ceiling,Red SWH* Strobe,High cd,White BBSCW-2 Back Box Skirt,Ceiling,White Ceiling Horn Strobes TR-HS Trim Ring,Wall,Red PC2R* 2-Wire Horn Strobe,Standard cd,Red TRW-HS Trim Ring,Wall White PC2RH 2-Wire Horn Strobe,High cd,Red TRC-HS Trim Ring,Ceiling,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White TRCW-HS Trim Ring,Ceiling,White PC2WH* 2-Wire Horn Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red PC4RH 4-Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standard cd,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP. t"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. *1 SYSTEM 02009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensotcom for �V SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version ofthis data sheet. A05-0395-007.4/09•#2132 41101 OF 1.* 4"I itre In I: Gamewell Series 9tIPA re/ FIRE CONTROL -1� 1# li INSTRUMENTS Vail Fire&Emergency Services 06/29/17 by Honeywell Description Analog Addressable Sensors The Gamewell-FCI XP-95 Series bases provide superior flexibility for the installation of the Gamewell-FCI, XP95 family of addressable detectors. Whether the project requires a 4.0" (10.16 cm), relay or sounder base, the XP95 *+ • family has a base to meet building aesthetics, constraints, retrofit limitations or functional needs. The device address C;, is held in the base, ensuring that the device address will + not be changed no matter how often a detector is replaced, • and verifying a consistent match between device type and • - device address. °r Each XP95 analog addressable head is compatible with a • co wide variety of XP-95 bases, ranging from one-piece low- Series 95 profile units to four-wire relay and sounder bases that can be controlled individually or as a group.The XP95 Series of Features detector bases has been designed to enable sensors to be plugged-in with minimum force and to have a "one-way- only" fit. Relay and sounder bases can be addressed and • Compatible with all of the Gamewell-FCI 600 Series controlled individually or by a group in response to the analog addressable detectors sensor alarms. • Base options include: — 4.0" (10.16 cm)or 6.0"(15.24 cm)ultra-low-profile Programming bases feature"one-way"fit with low insertion force — 6.0" (15.24 cm)relay base(4 wire) The only programming required at the Series 95 sensors is — Audible alarm sounder bases controlled individually address setting, via the patented XPert addressing card. or by group • The card is inserted into the sensor base.When the sensor Device address is stored in the sensor base • head is inserted into the base, the address is automatically Address is set by patented XPert addressing card • relayed to the sensor. Changing the sensor does not Compatible with all Gamewell-FCI XP95 protocol detection devices require additional programming since the address remains on the XPert Card located in the base. All other sensor- specific programming is accomplished at the Fire Alarm Control Panel (FACP). The XPert addressing card ensures that only the correct device types can be installed in given locations after cleaning or other maintenance operations. Installation The complete range of Series 95 addressable mounting An ISO 9000-2000 Company bases will accept any of the Series 95 sensors. The bases SIGNALING have a wide interior diameter for ease of access to wires 0 and terminals.The design of the base is such that the LISTED S1195 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2048 Rev.al page 1 of 2 , Installation (Continued) Specifications (Continue• 'Po sensor will fit in only one way, and a simple clockwise J-10 #11 motion (without force)is required to plug-in the sensor.The Relay Base mounting base will have provisions for the insertion of the Vail Fire&Emergency Services Model: XP95-B6R4 06/29/17 XPert addressing card as a means for programming and Alarm Current: 0.0036 A maintaining the sensor's address. Standby Current: 2 pA. Relay Rating: 0.04 A @ 125 VAC resistive The XP95-B4 base 4.0" (10.16 cm) will mount directly to a loading. 3.5" (8.89 cm) octagonal box (Raco 110 or equal) or a 4" Sounder Level: N/A (10.16 cm) octagonal box (Raco 125 or equal) with a round Captive Terminals: Yes cover/plaster ring (Raco 727 or equal). The other Series 95 bases 6.0" (15.24 cm) will mount directly to a 3.5" (8.89 cm) Sounder Base octagonal box (Raco 110 or equal); to a 4.0" (10.16 cm) Model: XP95-B65NDR octagonal box (Raco 125 or equal); or to a 4.0" (10.16 cm) Alarm Current: 0.030 A square backbox(Raco 190 or equal). Standby Current: 2 pA. Relay Rating: N/A Engineer's Specifications Sounder Level: 85 dB @ 10 ft.(3.048 m) Captive Terminals: Yes The contractor shall furnish and install, as indicated on the plans, either dual-chamber ionization (Gamewell-FCI Ordering Information model XP95-I) or photoelectric (Gamewell-FCI model XP95-P) smoke sensors, analog addressable multisensor Model Description (XP95-M) or electronic thermal sensor (Gamewell-FCI XP95-B4 4.0" (10.16 cm) mounting base with model XP95-T)with one of the several addressable mount XPert addressing card (four- ingbase available options. The combination sensor head XP95-B6R4 6.0" (15.24 cm)relay base p wire)with XPert addressing card and twist-lock mounting base shall be UL Listed and UL XP95-B6EZ 6.0" (15.24 cm)ultra-low-profile EZ- Listed as compatible with the Gamewell-FCI 600 Series fit mounting base with XPert analog addressable fire alarm control panels. The base addressing card shall permit free interchange of sensor heads without XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible requiring any additional wiring or additional programming alarm sounder in the base of the head or base. (MB-SDR-XP95) 30203 Remote LED (24 VDC) 71112 Additional Bbank XPert Specifications addressing cards 4" Base Model: XP95-B4 Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes 6" Base Model: XP95-B6EZ Alarm Current: N/A Standby Current: N/A Relay Rating: N/A Sounder Level: N/A Captive Terminals: Yes GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 ,CS-2048 Rev.al page 2 of 2 www.gamewell-fci.com 4%.;4111111111111141. I)*IA GameweII FIRE TRUCONTROL # 11 re/ INSMENTS Vail Fire&Emergency Services 06/29/17 by Honeywell Description Photoelectric Smoke Sensor The Gamewell-FCI XP95-P analog addressable photoelec- _ tric sensor operates with the Gamewell-FCI analog addres- sable Fire Alarm Control Panels (FACPs). The photoelectric sensor digitally transmits its address and the chamber's analog values to the FACP for analysis. The • - photoelectric sensor is distinguished by the clear status LED, which flashes red briefly when the device is polled _ and turns on continuously when the device is in alarm. J r-r-7Operation • 3 The XP95-P photoelectric sensor constantly monitors its sensing chamber and its internal electronics. The results are then reported along with the unit's address through the XP95-P integral communications electronics located in the sensor head. The XP95 photoelectric sensor utilizes a patented smoke chamber and infrared smoke sensing design. The Features infrared emitter generates a burst of light every second, or in response to direct interrogation. • Compatible with the Gamewell-FCI 600 Series analog In clean air, the photo diode receives no light from the addressable control panels emitter because of the arrangement of the chamber.When • Fits 4.0"(10.16 cm)or 6.0"(15.24 cm)ultra-low-profile smoke enters the chamber, it scatters light from the emitter E-Z fit bases onto the photo diode receptor in proportion to smoke char- • Audible alarm sounder base acteristics and density.As the smoke content in the cham- • Four-wire relay base ber increases, the signal from the photo diode receptor • Address is stored in the sensor base increases. This information is processed and conditioned • Address is set by XPert addressing card by an on-board, advanced-technology ASIC and digitally • Two-color status LED transmitted to the FACP. • Infrared smoke sensing design • Continuous communications Trouble and Alarm conditions of the XP95 sensors are • Optional remote LED actually determined at the control panel. The status infor- mation of each sensor is analyzed for off-normal conditions by the FACP. If the sensor reports a condition that matches its programmed trouble signature,the FACP will detect that the sensor is in trouble and will follow its programmed response sequence. If the status reported matches the alarm signature, the FACP will follow the programmed An ISO 9000-2000 Company alarm response for the specific device in alarm. When a SIGNALING sensor is in alarm,the integral LED in the sensor's housing will light continuously. LISTED ® MEA Approved 51195 APPROVED 149-99-E GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2007 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2054 Rev.al page 1 of 2 40 F 1,1r 111017.4711% •EC 1171. Operation (Continued) Ordering Information o, The XP95-P photoelectric device is connected to a two- Model Description Vail Fire&Emergency Services wire SLC carrying both data and a 17 to 28 VDC supply XP95-P Photoelectric sensor, anEr voltage, and is insensitive to loop connection polarity. A addressable(55000-650) remote LED indicator may be connected. The device is XP95-B4 4.0"(10.16 cm)mounting base with compatible with point-or group-addressable relay and XPert addressing card (45681-2101) sounder bases. XP95-B6R4 6.0"(15.24 cm)relay base (four-wire)with XPert addressing card Engineer's Specifications XP95-B6SNDR 6.0"(15.24 cm)mounting base with XPert addressing card and audible alarm The contractor shall furnish and install,where indicated on sounder in the base the plans, photoelectric smoke sensors with one of the 71112 Additional blank XPert addressing cards several addressable mounting base options available. The 30203 Remote LED (24 V)on single gang combination sensor head and twist-lock mounting base plate shall be UL Listed and UL Listed as compatible with the Gamewell-FCI 600 Series analog addressable fire alarm control panels. The base shall permit free interchange of sensor heads without requiring any additional wiring or additional programming of the head or base. The smoke sensor shall contain an integral LED that shall latch in when the unit goes into alarm. RF suppression techniques shall be employed to minimize false alarms. The photo- electric smoke sensor shall be the Gamewell-FCI model XP95-P. Specifications Standby Current: 340 pA Alarm LED Current: 0.00434 A Remote Alarm Output: 0.004 A @ 5 VDC Temperature Range: 32°F to 140°F(0°C to 60° C) Relative Humidity: (non-condensing)0%to 95% Recommended Spacing: Meets the 30 ft. (9.1 m)spacing guidelines in NFPA 72 Chapter 2. However, this spacing is based on ideal conditions and is to be used as a layout guide only.Appropriate installation-specific engineering is required. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2054 Rev.al page 2 of 2 www.gamewell-fci.com tellell OF 1.'44;4111111111111111 ! tjEiria Gamevvell PID95I ))r 1: FIRE TRUCONTROL 3QQ # INSTRUMENTS Vail Fire&Emergency Services 06/29/17 by Honeywell Description Point Identification Device The Gamewell-FCI PID-95P addressable point identifica- tion device is the interface between the non-powered, nor- mally open, dry-contact devices and Gamewell-FCI's 600 Series and IL195-E3 Series® of analog addressable Fire Gamewell-FCI • Alarm Control Panels (FACPs). Point identification devices PID-95P L1 monitor a single Style B circuit, and are designed for con- no 0 cealed mounting in an electrical backbox.The PID-95P can %DAV 51 be surface or flush mounted and has a visible LED for alarm/annunciation. • a, Operation PID-95P PID-95 The point identification device connects to the Signaling Line Circuit (SLC) via two wires. The PID-95 will monitor, via a two-wire supervised SLC circuit, contact-type devices Features such as a waterflow switch or a manual station. Upon acti- vation of the monitored device, the PID-95 will report its address to the 600 Series and IL195-E3 Series FACP via • Compatible with the Gamewell-FCI, 600 Series and the analog SLC. The control panel will then activate into all ILI95-E3 Series Systems alarm programmed outputs related to the PID-95. • Monitors dry-contact devices Programming • LED for alarm annunciation • Field programmable The PID-95 is programmed by setting a single DIP switch, • Priority interrupt easily accessible on the device's printed circuit board. The • Plate-mounted version available for surface or flush DIP switch sets the address of the device and the priority mounting in a 4"x 4.688"(10.16 cm x 11.908 cm)double interrupt (DIP SW #8). All other programming is accom- plished at the FACP through a laptop computer or the con- trol panel operator's display. (600 Series only). Standard Application The PID-95 is the interface between the dry-contact type devices and the SLC of the control panel. The PID-95 is a means of connecting and identifying monitor points without the use of conventional input modules at the main control panel.The use of PID-95s can dramatically reduce the field wiring required on many projects. An ISO 9000-2000 Company SIGNALING E3 Series®is a registered trademark of Honeywell International Inc. Microsoft®Windows®is a registered trademark of Microsoft®Corporation. LISTED ® MEA S521 APPROVED Approved 7300-1703:135 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2008 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com CS-2044 Rev. B page 1 of 2 , 40 F1'4/ tjrqr 1171. Engineer's Specifications Ordering Information +111110,t Addressable interface devices shall be provided for the monitoring and supervision of contact type devices con- Part Number Description Vail Fire&Emergency Services nected to the Fire Alarm Control Panel. The devices shall PID-95 Addressable point identifica4Mvice monitor a normally open dry contact. The addressable for monitoring contact devices interface devices shall communicate to the main control PID-95P Addressable input interface device panel via the analog addressable circuit. The interface mounted on 4.688"(11.908 cm)plastic plate device shall be Gamewell-FCI PID-95P or PID-95. 70839 Trim ring for flush-mounting on the PID-95P Specifications PID-95P Standby Current: 0.0005A, 0.0008A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F(0°C to 49°C) Relative Humidity: 93%, non-condensing Dimensions: 4"x 4.688"(10.16 cm x 11.908 cm), double gang backbox PID-95 Standby Current: 0.0005A, 0.0008 A Alarm Current: 0.0015A Operating Temperature: 32°F to 120°F(0°C to 49°C) Relative Humidity: 93%, non-condensing Dimensions: 4"(10.16 cm)square backbox with blank cover plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 CS-2044 Rev. B page 2 of 2 www.gamewell-fci.com