Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A17-0031_Talisman Unit 370 Fire-FA1_1498767900.pdf
tif al,i 11 a et P 4r IP 01 1r.- A0 . Vail &Emergen, Services / 6/29/1 General Notes install a rove orCircuit Specifications NAC 1- 14awg 2cond FPLR fire wire class B style Y. r r Sounder Power- 14awg 2cond FPLR fire wire class B style Y. — SLC CKT-16 awg 4 cond FPLR fire wire class A style 6. .d - _ • . e i r Typical Wirinc for Sounder ease Power O u- 20'-1" 1 14 AWG 2C FP for Sounder 'ower 16 AWG 4C F\ SBQP S= 2 P S P • I for SLC Ckt f 4 ' . i ♦ ;� XAddressable Circuit-Typical ai .:: FAMILY RM O : • i�<+ <+>sty<+>sty c+>� dn L.I I:J I ii B;1=1 1=1 •d. Al/®VMika1 Iloft above -t = J L I-1 I-1_ c eI. Style 6(Class 11 • 3C0 I II IJ —1 Heat or Smoke \, i \/ I — A Detector Base r? l� l� LJ LJ- o - EXISTING STAIR -© O 6" flue I(:uTsiIt1:I )Iu fmitcen hood EXISTIN;STAIR I S� P 9 II �at or Smakei SIP El) Detector Base a • - . . a. " , ref36aw all To H I ay H/S From nit below r r From FACP �i ' L CrOm CA�`D flierI �PPr r]anP -- Iv . 1 I be lass Equipment List Fire Alarm System 1 11 I (V door Quant. Symbol Device Manufacturer Part# rain ( tub BATH#2 XX O Smoke Detector Gamewell P XP95-P L--- ' o XX I Heat Detector ROR Gamewell XP95-T 1 IP Communicator 5/17 0BATH#1 ()RIF ro F a XX P Pull Station Gamewell MS95 T) soo tuu alto Fl N built in cab closet 41 ele��ct�ac :,7,, ° ° XX " Strobe System Sensor SCW CLOSETo hgt 6's" / tal XX SpkrMultidb System Sensor SPCWV \ No. Revision/Issue Date / 1..f HEAD ROOM c XX System Sensor LLLLJJJJ built in closet • .� built in dresser cat • "' Speaker Strobe y SPSCWV o closet cab r xx V Flow Switch Gamewell PID 95 5' TALL HEAD ROOM LINE N XX Tamper Switch Gamewell PID 95 Prepared by: 10 BED RM#1 6ED RM#2 • XX © Duct Detector Gamewell XP95-PD \, • hgt 42" .. L access panel / 4 SBOP smoke+sounder base Gamewell B6SNDR SI3OP a3 co SBOqueen bed XX ©P smoke+heat combo Gamewell XP95-M queen bed -o XX ? low* Gamewell PID-95 xx AUX Aux.Power Supply Gamewell GFPS-9 CERTIFIED — — PWR *41, Level 2 ®CO CO Detector Gamewell PID-95nf_ a Soffit XX SCE Signal Control Elem. Gamewell SCE-95 7. 1 soffit Talisman Unit 370 Acme Alarm Company 24'-0" Firm Name and Address Clint Bartels,SET System Designer NICET#104519 Fire Alarm Systems,Level IV Reliable. Acme Innovative. Solutions Oriented. Fire Alarm COMPANY 970.625.5535 clint@acmealarm.com "Providing Life Safety Solutions" www.acmealarm.com� Project Ncme and l,cdress Talisman 62 East Meadow Drive Unit 370 Remodel Vail, CO 81657 Project Shee; Fire Alarm System I P 1J:tL' 6 /19 /17 FA1 Scale 3/1 6" 1 ' NORTH