HomeMy WebLinkAboutA17-0032_FA-0_1499788320.pdf cTI:IFC2015 Occupancy Class - Residential multi- BATTERY CALCULATIONS SYSTEM OUTPUTS family 907. 2. 11 . 2 Group R- 3. Single or 07/11/Vail 17 re&Emergency Services CONTROL PANEL LOCATION: 1st Level Mechanical ANNUNCIATION NOTIFICATION multiple station smoke alarms shall be HOURS OF SUPERVISION: 24 HOURS installed regardless of occupant load at PANEL: GE Concord 4 0 MINUTES OF ALARM: 15 MINUTES c E all of the following locations: Device Device Total '2 1 . On ceilingor wall outside each separate Total Alarm QTY PART NUMBER Standby Alarm Standby Current H o › p DESCRIPTION OF DEVICES Current Current Current sleeping area . 1 GE Concord 4 FACP 0.0000 0.0000 0.0000 0.0000 ° �' G t 2. In each room used for sleeping 1 ATP-1000 Annunciator 0.0120 0.1100 0.0120 0.1100 p c - o 1 60-758 4 output snapcard 0.0060 0.0400 0.0060 0.0400 �. . - I z 0 _ ,q ,, 3. In each story within dwelling unit Property: 2 SYS COSMOD Interface module 0.0450 0.1210 0.0900 0.2420 > g g 1 9 N - 3 SYS 2WTAB Monitored Smoke Detector 0.0000 0.0200 0.0000 0.0600 -,71 -7d,, Q a G t-- '' Marx 4 SYSCOSMO Smoke'CO combo 0.0000 0.0200 0.0000 0.0800 - , 2 a x x .� NFPA 72 2016 29 . 5. 1 . 1 Smoke alarms shall be installed: • .y ° a Residence g c ° C ° E 1 . In all sleeping rooms and guest rooms 1 60-774 8 Zone Expansion Module 0.0380 0.2300 0.0380 0.2300 ,, u . ° ° 8 ti o . o 1 SYS-INHW Interior Siren 0.0000 0.0750 0.0000 0.0750 ¢ c c H H w w - - y y • 1 C' 0 2. Outside of each sleeping area within 21 ft of door 1 SYS-5603 135 degree fixed heat detector 0.0000 0.0000 0.0000 0.0000 V V V V � ° ° ° ° ° ° ° ° ° ° ° � � � � o p g Address: TOTAL: 0.146 0.837 Q d d c, H H H z On everylevel ,Smoke or Heat Detector X X X X X 3. ve l , including basements. 2627 Arosa Drive STANDBY Carbon Monoxide Detector X x x x x 4. In living areas o f u e s t suite Vail Colorado 81657 SUB-TOTAL: 0.15 AMP Ground Fault X X X X g ' 24 HOURS OF STANDBY: 24.00 HOURS Open Circuit x x x x x Owner: SUB-TOTAL: 3.50 AMP HOURS LowBatery X X X X _ X N F P A 720 Lawrence & Jennifer Marx ALARM: AC Power Failure X X X X X 44 Cook St. Suite 705 SUB-TOTAL: 0.84 AMP Telephone Line Fault daily tuner test x x x 8. 4. 1 . 1 Carbon monoxide detectors shaIl be installed : Denver, CO 80206 15 MINUTES OF ALARM: 0.25 HOURS Peel Silence Feature X 1 . Outside each sleeping area in immediate vicinity. General Contractor: SUB-TOTAL: 0.21 AI\IP HOURS SRE Builders TOTALS: 2. 0 n every level 23698 HWY 24 Suite D-2 TOTAL SUPERVISORY: 3.50 AMP HOURS 3. Other location where required by law, code or standard. Minturn, CO 45-635 5 TOTAL ALARM: 0.21 AMP HOURS Ph. 970-845-6359 TOTAL: 3.71 AMP HOURS Project Mgr: *SPARE OF 20% 0.74 AMP HOURS_ HB1091 Carbon monoxide detectors shall be installed MINIMUM BAI IE,RY SIZE REQUIRED 4.46 AMP HOURS Code Complience: BATTERIES SUPPLIED 2 x 7 amp 7.00 AMP HOURS within 15 feet of bedroom door and within 25 feet of a 2015 International Fire Code fuel fired appl i a n c e, fire l a c e, o r a r a e. 2016 NFPA-72 Nat. Fire Alarm Code f-' p p g g 2015 NFPA-70 Nat. Electrical Code BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL VAIL FIRE INSTALLATION STANDARDS (Rev 4/16 ) : Levels: Detection location and spacing shall be per latest NFPA72 2 Levels Bldg Height: 2015 IFC and as set forth : ' 14'± Roof Height Approved install As this is an unsprinklered building, insurance company requires 1 . Installed i n a corridor not more than fifteen feet from a heat detector in the garage, Occupancy Loads: the door of the farthest bedroom 2. Smokes req 'd in living rooms, family rooms, home Occupancy Rating: theaters and any rooms that may be used for sleeping . Residential - R-3 3. Detectors installed toward middle of room with Structure: consideration o f bathrooms, ceiling fans and air ducts. Type VB/Non-Rated/Non-Sprinkled • 4 Kitchens and garages are not required to have heat Sq. Footage: detection . 2,972 SqFt± 5. Storage rooms, closets, unfinished crawl spaces not Communication Type: g p DACT/POTS Lines (vain Level required to have smoke detection . n �'U OCO q Primary Power Location: Carbon Monoxide detection required per latest NFPA72 and MainElecPanel - Breaker# L< Colorado H B 10 91 . In addition : submittal Prepared By: Bell 1 1 . CO to be instaled no further than 15 feet from furthest -"Ni ANN GE O, Co Lower Level Opo bedroom . a SAE Concord 4 2. Within 20 feet of fuel fired appliances, including stoves, FACP 0135° Superior Alarm & Electronics PANEL F gas, fire places, wood burning stoves or wood burning fire 210 Edwards Viii. Blvd. #A108 I RISER DIAGRAM places. PH 970-926-8788 Phonelines (1) 120 VAC FX 970-926-8790 Dedicated 3. Entrance vestibules from attached garages. brad@superioralarmco.com Ba8 AH Batttt Backup 4. Areas with gas fired appliances that pose safety risk. MONITORING Syster-n Coce eference API - DENVER COLORADOREMOTE STATION SYMBOL DESCRIPTION SYS# 6101-1759 NATIONAL INSTITUTE FOR CERTIFICATION FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE IN ENGINEERING TECHNOLOGIES Fire Protection Engineering Technology sap SMOKE DETECTOR (PHOTOELECTRIC) HORN/SOUNDER Fire Alarm Systems DESCIPTIO\ CLASS STYLE TYPE 0135' HEAT DETECTOR FIXED/ROR (TEMP LISTED) 171(1 HORN WITH STROBE F 15 (NUMBER INDICATES CANDELA) A significant remodel of an existing single family residence is taking NOTIFICATION APPLIANCE CIRCUIT 4 #18 AWG FPL ANN ANNUNCIATOR 15 STROBE (NUMBER lace in the Town of Vail . The residence will not be s rinklered . AC POWER B Y 4 #18 AWG FPL INDICATES CANDELA) p p INITIATING DEVICE CIRCUITS f 4 #18 AWG FPL iZ-1 WATER FLOW SWITCH Matt Madden We will install smoke and carbon monoxide combination devices inEOL RE END OF LINE RESISTOR NICET #134111 Level III /- i VALVE WITH TAMPER SWITCH Valid Thru 05/1/18 applicable locations and system will be zoned by floor. Our • OAIM INPUT MODULE k FIRE DEPARTMENT "KNOX" BOX ORIG.6/16/16 SCALE: 1/8"=1'O" installation will meet Town of Vail Standards and applicable codes. USE PLENUM RATED WIRE IN ALL PLENUM SPACES AIM C0 MONITORED CARBON MONOXIDE DETECTOR REV. DATE NOTES: / / 0 WI E CHART ®CO SMOKE/CARBON MONOXIDE COMBO DETECTOR /1\ Scope of Work A LEGEND FINAL INSP. ) AS BUILTS: OCO AHJ: Vail Fire Department Mike Vaughan, Fire Marshal Permit #: PAGE NAME: Title/Bldg/Cake/Map AHJ : Vail Fire Department - Fire Marshal Mike Vau han 970-479-2252 A 0 SHEET 1 OF 3 J