HomeMy WebLinkAboutA17-0032_FA-0_1499788320.pdf cTI:IFC2015 Occupancy Class - Residential multi-
BATTERY CALCULATIONS SYSTEM OUTPUTS
family 907. 2. 11 . 2 Group R- 3. Single or 07/11/Vail 17 re&Emergency Services
CONTROL PANEL
LOCATION: 1st Level Mechanical ANNUNCIATION NOTIFICATION multiple station smoke alarms shall be
HOURS OF SUPERVISION: 24 HOURS installed regardless of occupant load at
PANEL: GE Concord 4 0
MINUTES OF ALARM: 15 MINUTES c E all of the following locations:
Device Device Total '2 1 . On ceilingor wall outside each separate
Total Alarm
QTY PART NUMBER Standby Alarm Standby Current H o › p
DESCRIPTION OF DEVICES Current Current Current sleeping area .
1 GE Concord 4 FACP 0.0000 0.0000 0.0000 0.0000 ° �'
G t 2. In each room used for sleeping
1 ATP-1000 Annunciator 0.0120 0.1100 0.0120 0.1100 p c - o
1 60-758 4 output snapcard 0.0060 0.0400 0.0060 0.0400 �. . - I z 0 _ ,q ,, 3. In each story within dwelling unit Property:
2 SYS COSMOD Interface module 0.0450 0.1210 0.0900 0.2420 > g g 1 9 N -
3 SYS 2WTAB Monitored Smoke Detector 0.0000 0.0200 0.0000 0.0600 -,71 -7d,, Q a G t-- '' Marx
4 SYSCOSMO Smoke'CO combo 0.0000 0.0200 0.0000 0.0800 - , 2 a x x .� NFPA 72 2016 29 . 5. 1 . 1 Smoke alarms shall be installed: •
.y ° a Residence
g c ° C ° E 1 . In all sleeping rooms and guest rooms
1 60-774 8 Zone Expansion Module 0.0380 0.2300 0.0380 0.2300 ,, u . ° ° 8 ti o . o
1 SYS-INHW Interior Siren 0.0000 0.0750 0.0000 0.0750 ¢ c c H H w w - - y y •
1 C' 0 2. Outside of each sleeping area within 21 ft of door
1 SYS-5603 135 degree fixed heat detector 0.0000 0.0000 0.0000 0.0000 V V V V
� ° ° ° ° ° ° ° ° ° ° ° � � � � o p g Address:
TOTAL: 0.146 0.837 Q d d c, H H H z On everylevel ,Smoke or Heat Detector X X X X X 3. ve l
, including basements. 2627 Arosa Drive
STANDBY
Carbon Monoxide Detector X x x x x 4. In living areas o f u e s t suite Vail Colorado 81657
SUB-TOTAL: 0.15 AMP Ground Fault X X X X
g '
24 HOURS OF STANDBY: 24.00 HOURS Open Circuit x x x x x
Owner:
SUB-TOTAL: 3.50 AMP HOURS LowBatery X X X X _ X N F P A 720 Lawrence & Jennifer Marx
ALARM: AC Power Failure X X X X X 44 Cook St. Suite 705
SUB-TOTAL: 0.84 AMP Telephone Line Fault daily tuner test x x x 8. 4. 1 . 1 Carbon monoxide detectors shaIl be installed : Denver, CO 80206
15 MINUTES OF ALARM: 0.25 HOURS Peel Silence Feature X
1 . Outside each sleeping area in immediate vicinity. General Contractor:
SUB-TOTAL: 0.21 AI\IP HOURS SRE Builders
TOTALS: 2. 0 n every level 23698 HWY 24 Suite D-2
TOTAL SUPERVISORY: 3.50 AMP HOURS 3. Other location where required by law, code or standard. Minturn, CO
45-635 5
TOTAL ALARM: 0.21 AMP HOURS
Ph. 970-845-6359
TOTAL: 3.71 AMP HOURS Project Mgr:
*SPARE OF 20% 0.74 AMP HOURS_ HB1091 Carbon monoxide detectors shall be installed
MINIMUM BAI IE,RY SIZE REQUIRED 4.46 AMP HOURS Code Complience:
BATTERIES SUPPLIED 2 x 7 amp 7.00 AMP HOURS within 15 feet of bedroom door and within 25 feet of a 2015 International Fire Code
fuel fired appl i a n c e, fire l a c e, o r a r a e. 2016 NFPA-72 Nat. Fire Alarm Code
f-' p p g g 2015 NFPA-70 Nat. Electrical Code
BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL
VAIL FIRE INSTALLATION STANDARDS (Rev 4/16 ) : Levels:
Detection location and spacing shall be per latest NFPA72 2 Levels
Bldg Height:
2015 IFC and as set forth :
' 14'± Roof Height
Approved install As this is an unsprinklered building, insurance company requires 1 . Installed i n a corridor not more than fifteen feet from
a heat detector in the garage, Occupancy Loads:
the door of the farthest bedroom
2. Smokes req 'd in living rooms, family rooms, home Occupancy Rating:
theaters and any rooms that may be used for sleeping . Residential - R-3
3. Detectors installed toward middle of room with Structure:
consideration o f bathrooms, ceiling fans and air ducts. Type VB/Non-Rated/Non-Sprinkled
• 4 Kitchens and garages are not required to have heat Sq. Footage:
detection . 2,972 SqFt±
5. Storage rooms, closets, unfinished crawl spaces not Communication Type:
g p DACT/POTS Lines
(vain Level required to have smoke detection .
n �'U OCO q Primary Power Location:
Carbon Monoxide detection required per latest NFPA72 and MainElecPanel - Breaker#
L< Colorado H B 10 91 . In addition : submittal Prepared By:
Bell 1
1 . CO to be instaled no further than 15 feet from furthest -"Ni
ANN
GE O, Co Lower Level Opo bedroom .
a SAE
Concord 4 2. Within 20 feet of fuel fired appliances, including stoves,
FACP 0135° Superior Alarm & Electronics
PANEL F gas, fire places, wood burning stoves or wood burning fire 210 Edwards Viii. Blvd. #A108
I RISER DIAGRAM places. PH 970-926-8788
Phonelines (1) 120 VAC FX 970-926-8790
Dedicated 3. Entrance vestibules from attached garages. brad@superioralarmco.com
Ba8 AH
Batttt Backup 4. Areas with gas fired appliances that pose safety risk.
MONITORING
Syster-n Coce eference API - DENVER COLORADOREMOTE STATION
SYMBOL DESCRIPTION SYS# 6101-1759
NATIONAL INSTITUTE FOR CERTIFICATION
FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE IN ENGINEERING TECHNOLOGIES
Fire Protection Engineering Technology
sap SMOKE DETECTOR (PHOTOELECTRIC)
HORN/SOUNDER Fire Alarm Systems
DESCIPTIO\ CLASS STYLE TYPE 0135' HEAT DETECTOR FIXED/ROR (TEMP LISTED) 171(1 HORN WITH STROBE
F 15 (NUMBER INDICATES CANDELA)
A significant remodel of an existing single family residence is taking NOTIFICATION APPLIANCE CIRCUIT 4 #18 AWG FPL ANN ANNUNCIATOR 15 STROBE (NUMBER
lace in the Town of Vail . The residence will not be s rinklered . AC POWER B Y 4 #18 AWG FPL INDICATES CANDELA)
p p INITIATING DEVICE CIRCUITS f 4 #18 AWG FPL iZ-1 WATER FLOW SWITCH Matt Madden
We will install smoke and carbon monoxide combination devices inEOL RE END OF LINE RESISTOR NICET #134111 Level III
/- i VALVE WITH TAMPER SWITCH Valid Thru 05/1/18
applicable locations and system will be zoned by floor. Our • OAIM INPUT MODULE k FIRE DEPARTMENT "KNOX" BOX ORIG.6/16/16 SCALE: 1/8"=1'O"
installation will meet Town of Vail Standards and applicable codes. USE PLENUM RATED WIRE IN ALL PLENUM SPACES AIM C0
MONITORED CARBON MONOXIDE DETECTOR REV. DATE NOTES:
/ / 0 WI E CHART ®CO SMOKE/CARBON MONOXIDE COMBO DETECTOR /1\
Scope of Work
A
LEGEND FINAL INSP.
)
AS BUILTS:
OCO AHJ: Vail Fire Department
Mike Vaughan, Fire Marshal
Permit #:
PAGE NAME: Title/Bldg/Cake/Map
AHJ : Vail Fire Department - Fire Marshal Mike Vau han 970-479-2252
A 0
SHEET
1 OF 3 J