HomeMy WebLinkAboutA17-0032_FA-1_1499788320.pdf ( O1 :e b,� OS��
147100
Vail Fire&Emergency Services
07/11/17
Property:rorTh/Th C, owen eve Marx
Residence
Address:
2627 Arosa Drive
ABOVE Vail, Colorado 81657
lb ij4
0 POWDER �� GFI O� ° GFI O ( 30 ) HIS OFFICE all
Owner:
1 Lawrence &Jennifer Marx
T 5 j co 44 Cook St. Suite 705
I I h I 5 — J > Denver, CO 80206
3 I WET 8 El`
6 = w 4 El 2 <)
GeneralContractor:�' 4 = II PANTRY = _
I 8 '254 6 - BAR GAME _ O _ CO_ 3 O i SRE Builders
23698 HWY 24 Suite D-2
6 El – -1 4 `254 2 = �7 m o Minturn, CO 81645
I7
Ph. 970-845-6359
�, 5 n- ( 26 ) 7 ) c VI'ID = ° 51/2" __—_: m 14' - 9.. 5' - 2" ProjectMgr:
M r
I I 3 O � �i
— — — J IT GFI _ @ - �1 — Code Complience:
® 19 L — — — I] 77' `-1 ® �` ■��= 2015 International Fire Code
i =I �� BARN DOOR �1
2016 NFPA-72 Nat. Fire Alarm Code
2015 NFPA-70 Nat. Electrical Code
20 'T Woo i 1 WALLS TO BE
A3� Wr /� REMOVED TYPICAL
MATER / 3 - ° Levels:
_ l 2 Levels
1 P( A256 \ �� /� GFI I - Bldg Height:
u
\ _ _ _ _ i o
o F _18> 0 14'± Roof Height
1
TV � I � � � Occupancy Loads:
1 , _._ ,_ -0I
A300 f N 1 z
c,iI`I - ` - - - __ 1. 4 El 2 KITCHEN =
Jci
Occupancy Rating:
J I I = ® I 2 A250 2 o
I `Y' III - r"' 3' -4114'8 8' - 8112" `r' _, w Residential-R-3
�n � H _ z
c� i it �VIASTGR JC I Q Structure:
1 � � i _ Type VB/Non-Rated/Non-Sprinkled
-, III = - s} , I w � 2 - r
— — � �I _ 31/2" 3112" ® _ CD Q I DW I 9 LIVING II 19 o Sq. Footage:
7' 1"
- I_ - - 7'-03 III -, 3' 2" 1,j( 3' _ 2" , , (..9 i: L — — — _I ` ° ° J I I u_ 2,972 SgFt±
7,972' - 11" J o
_ N - _ I @ o 4' - 6" I Communication Type:
- ---' Q ; ENTRY 3 0 DACT/POTS Lines
r w
� z '
// t24\ 1 ^� 2 ci...
-i I Com _1] Primary Power Location:
° J - _, EL- - - - Pill A1300 LLv = s l _ N Main Elec Panel-Breaker#
c - Submittal Prepared By:
_� / I 2co
II DINING FRPLC o @� ,
M \ / I \t /C18 9 II 2' - l" @ _ N / —
4' -2114" ON II i��- a SAE
[[
_ I - I I o/ –\,— iiiik ' Eri– – – –
\ Lu
I Superior Alarm & Electronics
I m C28 ) 210 Edwards Vill. Blvd. #A108
r850
PH 970-926-8788
"' I ENLARGED ' ' -/0 114'
FROSTED GLASS27 T -- --- T II v ao7_, brad@FX superi970-9oralar6-8mco.com90
` d L FRONT DOOR, I
ALIGN WITH
O O MONITORING
(10) ABOVE OPENING
(9 ) `\ / K 6 I I API - DENVER COLORADO
i p REMOTE STATION
a u � d b II SYS# 6101-1759
NATIONAL INSTITUTE FOR CERTIFICATION
IN ENGINEERING TECHNOLOGIES
Fire Protection Engineering Technology
11 Fire Alarm Systems
Matt Madden
NICET #134111 Level III
Valid Thru 05/1/18
ORIG.6/16/16 SCALE: 1/8"=1'0"
REV. DATE NOTES:
A
/2\
FINAL INSP.
AS BUILTS:
AHJ: Vail Fire Department
Mike Vaughan, Fire Marshal
Permit #:
PAGE NAME: Title/Bldg/Calcs/Map
AHJ : Vail Fire Department - Fire Marshal Mike Vaughan 970-479-2252 A 1
SHEET
2 OF 3 J