HomeMy WebLinkAboutB16-0031_A10.1_1480362900.pdfA4.3
A4.4
1
1
A4.1
1
A4.5
2
A4.5
3
1
A5.5
1
A5.7
1
A5.6
2
A5.5
A4.5
1
1
A5.1
4
A5.5
2
A5.7
1
A5.2
1
A5.3
2
A5.4
3
A5.5
1
A5.8
1
A5.9
BEDROOM #5
015
AV EQUIP. RM.
012
BATH #5
011
W.C.
010
HALLWAY
007
STORAGE
009
LAUNDRY ROOM
006
WINE RM.
003 WET STORAGE
004
FAMILY ROOM
001
MECHANICAL
ROOM
008
EXERCISE
EQUIPMENT
STORAGE
017
POWDER
005
STAIRS
002
1
1
2
2
3
3
4
4
5
5 6
6 7
7 8
8 9
9
10
10 11
11 12
12
A
A
B
B
C
C
D
D
E
E
F
F
H
H
K
K
L
L
M
M
G1
G4
GD
GD
GC
GC
GA
GA
GB
GB
I
I
J J
G5
G2
2' - 4" 3' - 6 1/2" 4' - 5 1/2" 15' - 0 1/2" 11 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4"
82' - 2"
13' - 2"8' - 6 1/2"1' - 9 1/2"
23' - 6"
17' - 4 1/2"
6' - 7 1/2"
5' - 9"
1' - 9 1/2"8' - 6 1/2"13' - 2"
1' - 3"
1' - 0"1' - 4"10" 12' - 3" 3' - 6" 2 3/8" 8' - 11 3/16" 6 5/16" 4' - 11 1/8" 3' - 0" 37' - 9"
23' - 6"
G3
1
A5.10
FAN
FAN
E
Q
Q
H2
H2
FAN
FAN
U
U
D5 D5
A
A A A A
A
A
A A
A
A A A
A
A
A A
A
A A
A
A5
L
H2
H2 A
A
L
A3
A3
CLG
FAN
L2
L2
Q2 Q2
FAN A A
F
H H
H2
L2
L
A
A
PROVIDE POWER
FOR FUTURE LIGHTING DESIGN AND
FUTURE COOLING PER MECH. SPEC.
Q2
55" TV ABOVE FIREPLACE
WOOD WRAPPED STEEL BEAMS RE: STRUCT.
TV
BATH #5 SHOWER
011B
LED LIGHTING IN CABINETRY ON LIGHTING SYSTEM
MS
CNTR
FRIDGE
CNTR
ICE MAKER
CNTR
PROVIDE POWER IN
MECHANICAL ROOM PER
MECHANICAL EQUIPMENT
AND SPEC.
B.O. SOFFIT @ 7 1/4"
GAS
OUTSIDE AIR INTAKE FOR
KITCHEN MAKE UP AIR SYSTEM
RE: MECH.
SHALLOW FLOOR
STRUCTURE ZONE FOR
MECHANICAL DUCTS.
RE: STRUCT..
AC UNIT
COMPRESSOR
PROVIDE POWER FOR MASTER
BEDROOM A/C COMPRESSOR UNIT PER
MECH. SPEC. PROVIDE POWER FOR
POTENTIAL A/C/ @ MAKE UP AIR AND
BEDROOM #3
PROVIDE POWER FOR AV
EQUIPMENT PER AV
CONSULTANT AND
EQUIPMENT SPEC.
CNTR
220
WASHER
CNTR GFI
GFI
GFI
220
9
A6.7
FLOOR LAMPS
3' - 5 7/8"
3' - 5 7/8"
A U
7"X9" ACTUAL
9"X9" ACTUAL
A
D9
(2) BUNK READING LIGHTS
1-HIGH; 1-LOW.
D7
D7
F
UPLIGHTS
A2
A
A
A A
A5
K
K
K1
4
A4.5
A A A
B.O. SOFFIT @ 9' - 8 5/8" AFF
B.O. GWB @ 9' - 0 3/4" AFF
B.O. GWB @ 9' - 0 3/4" AFF
B.O. GWB @ 9' - 0 3/4" AFF
B.O. GWB @ 8' - 2 3/8" AFF
B.O. GWB @ 8' - 3" AFF
B.O. GWB @ 9' - 0 3/4" AFF
(2) OUTLETS
1-HIGH; 1-LOW.
TELEPHONE/
DATA
G
G
A4.3 3
A4.2
1
Q
1
A5.11
4 7/8"
PRE-WIRE SHADE POCKET FOR FUTURE MOTORIZED
SHADE. INSTALL MANUAL SHADE.
PRE-WIRE SHADE
POCKET FOR FUTURE
MOTORIZED SHADE.
INSTALL MANUAL SHADE.
JS
001
002
003
1
A8.1
1
A8.1
2' - 11 3/4"
2' - 11 3/4"
2' - 11 3/4"
2' - 11 3/4"
K
1 7/8"
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
9/16/2016
10:40:46 AM
A10.1
LOWER
LEVEL RCP
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
GENERAL NOTES:
1) EXTERIOR LIGHTING:
1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 14 LIGHTS ARE ALLOWED. 14 EXTERIOR LIGHTS MORE
THAN 18" ABOVE GRADE ARE PROPOSED. SEE ELECTRICAL PLANS FOR TYPE, LOCATION AND NUMBER
OF FIXTURES.
(1) WALL MOUNTED HEVI LITE HL-340-LED SCONCE (TYPE E) LIGHTS PROVIDED @ THIS LEVEL
(3) WAC LIGHTING WL-LED200 STEP LIGHT (TYPE Q) LIGHTS PROVIDED 1' - 0" ABOVE F.F. @ THIS LEVEL
________________________________________
1 TOTAL EXTERIOR LIGHTS MOUNTED MORE THAN 18" ABOVE GRADE AT THIS LEVEL
2) (0) MOTORIZED SHADES SHOWN ON THIS LEVEL.
3) PROVIDE SHADE POCKETS @ ALL WINDOWS.
4) PRE-WIRE U.N.O.
1/4" = 1'-0"
1
LOWER LEVEL REFLECTED CEILING
PLAN
CLG
FAN
CLG
FAN
- UPATED GENERAL NOTE AND
SHADE COUNT.
- SWTCHES AND WIRING
MODIFIED IN BEDROOM #5
- WINDOW TAGS ADDED
No. Revision Date
Revision
Description
1 APRIL 26, 2016 ASI #1
5 AUGUST 12,
2016
ASI #5
11/28/16