HomeMy WebLinkAboutB16-0031_A4.2_1480363080.pdfMATERIALS 1. STANDING SEAM METAL ROOF - COPPER RE: SPEC 2. SYNTHETIC SHAKE ROOF RE: SPEC 3. 6X10 WOOD RAFTERS. RE: STRUCT 4. 8X10 RAFTERS RE: STRUCT 5. 2X10 FASCIA 6. 10X14 WOOD OUTLOOK BEAM RE: STRUCT. 7. 8X12 WOOD EAVE BEAM 8. COPPER SHINGLE SIDING RE: SPEC 9. DRY STACKED STONE VENEER RE: SPEC & FINISH SCHEDULE 10. RECLAIMED VERTICAL WOOD SHIP LAP SIDING W/ NO REVEAL BETWEEN BOARDS RE: SPEC & FINISH SCHEDULE 11. HORIZONTAL SHIP LAP SIDING W/ 1/4" REVEAL RE: SPEC & FINISH SCHEDULE 12. 3X3 WOOD TRIM 13. LIFT AND SLIDE DOOR SYSTEM 14. STEEL C-CHANNEL WINDOW HEADER. RE: STRUCT 15. PFSM CLAD PANEL SIDING PAINTED TO MATCH WINDOWS 16. CUT STONE CAP W/ 10 PERCENT MIN. SLOPE AT TOP TO SHED WATER 17. STEEL BEAM. RE: STRUCT 18. 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTIONS @ WALL AND LAG BOLTED TO STEEL BEAM 19. TYPICAL STEEL HANDRAIL PAINTED CUSTOM BLUE/BLACK COLOR 20. 5" ROUND PFSM GUTTER AND 3" DOWNSPOUT. PIPE UNDERGROUND TO DAYLIGHT OUTSIDE OF AREA OF EXCAVATION FOR FOUNDATION AND PROVIDE POWER FOR HEAT TAPE. 21. 10X10 WOOD DECK COLUMN OVER STEEL CAP AND 4X4 HSS COLUMN BASE 22. CUSTOM STEEL CHIMNEY CAP 23. 4" THICK STONE CHIMNEY CAP 24. WOOD BEAM 25. WOOD OUTLOOK BEAM 26. CURVED GLULAM BEAM RE: STRUCT 27. STEEL SPIRAL STAIRCASE 28. PROVIDE RECESS SHADE POCKET ABOVE WINDOW GENERAL NOTES: 1. EXTERIOR LIGHTING: SEE LIGHTING PLANS FOR ALL EXTERIOR LIGHTING AND LIGHTING SCHEDULE 2. SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR MORE INFORMATION ON COLORS. SEE OUTLINE SPEC AND ARCHITECTURAL FINISH SCHEDULE. 3. ALL SNOW CLIPS (PADS) AS SHOWN ON THE ROOF AND ABOVE ALL DOORS AND DECKS TO BE AN ENGINEERED SYSTEM PER ROOF TYPE AND SLOPE INSTALLED PER MANUFACTURES RECOMMENDATIONS 4. ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O. 5. WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH. a. B.O. WINDOW HEADER DIMENSIONS ARE MEASURED TO THE WINDOW UNIT R.O. RE: THE WINDOW SCHEDULE AND DETAILS FOR ACTUAL PLACEMENT OF THE STRUCTURAL HEADER b. MOTORIZED SHADES TO BE PROVIDE IN SHADE POCKET @ ALL LARGE WINDOW OPENINGS THROUGHOUT THE HOUSE. RE: WINDOW SCHEDULE 6. ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES, ETC, TO BE PAINTED TO MATCH THE DARK BRONZE WINDOW COLOR. 7. EXTERIOR HANDRAIL VERTICAL AND HORIZONTAL SUPPORTS TO BE PAINTED STEEL TO MATCH WINDOW COLOR. 8. ALL MECHANICAL VENT TO BE COPPER U.N.O. 9. SEE WINDOW SCHEDULE AND RCP FOR INDICATION OF WHICH WINDOWS HAVE A CONCEALED SHADE POCKET. MAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" LOWER LEVEL FINISHED FLOOR 1' - 6 1/4" 1 A5.1 4 A5.5 1 5 10 6 17 28 18 10 12 14 19 12 8 21 8 22 23 3 14 6 9 4 17 21 9 10 8 19 12 24 16 3 13 5 3 9 17 24 16 CENTOR SCREEN AT OPENING. TRACK TO BE PROVIDED AT HEADER AND SILL. ROLLER TO BE ATTACHED TO WEILAND FIXED PANEL FRAME. 15 15 15 5 A6.9 5 A6.9 7 A6.9 8 A6.11 8 A6.11 A6.10 1 2 A6.6 3 A6.6 1 A6.6 4" / 12" 3 A6.9 4 A8.1 7 A8.1 5 A6.7 A6.5 5 1 A6.8 A6.7 2 A6.7 3 1 A6.11 2 1/2" / 12" 6 " / 1 2" 2 A6.5 2 A6.3 6 A6.9 A6.1 4 27 1 A5.2 1 A5.3 1 A5.4 4 A8.1 5 A8.1 6 A8.1 1 A5.9 Q 6 TYPE "M" LIGHT FIXTURES 24 108 27 108 27 108 28 108 32 110 52 110B 52 110B 52 110B 52 110B 35 111 36 111 38 112 38 112 39 112 61 207 62 207 67 209 63 208 J-BOX STL. SPIRAL STAIRCASE PAINTED TO MATCH BRONZE WINDOW COLOR TYPE "Q" STEP LIGHT DOWN SPOUT 1 2 3 4 5 6 7 8 9 10 11 12 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 15' - 0 1/2" 11 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" Q MOTORIZED SHADE POCKETS INDICATED WITH DASHED LINE AND HATCH RE: RCP MOTORIZED SHADE POCKETS INDICATED WITH DASHED LINE AND HATCH RE: RCP 4' - 0" 2' - 6" T.O. STRUCTURE @ 39' - 5 7/8" 6" / 12" SEE SECTION 2/A5.7 FOR ELEVATION UNDER DECK 37 111 34 111 62 207 61 207 18 106 18 204 12' - 0" 10' - 5" SEE SHEET 2/A5.10 FOR ELEVATION UNDER DECK BUILDING HEIGHT LIMIT 33' ABOVE EXISTING GRADE @ ROOF RIDGE EXISTING GRADE DIRECTLY BELOW BUILDING HEIGHT *4A BUILDING HEIGHT @ 32' - 9 3/4" ABOVE EXISTING GRADE EXISTING GRADE @ 7' - 2" BUILDING HEIGHT LIMIT 33' ABOVE EXISTING GRADE @ ROOF RIDGE EXISTING GRADE DIRECTLY BELOW BUILDING HEIGHT *2A 33' - 0" T.O. STL. BEAM @ 22' - 0 3/4" T.O. STL. BEAM @ 22' - 0 3/4" EXISTING GRADE @ 6' - 7" T.O. STRUCTURE @ 39' - 4 3/4" 66 209 65 209 64 209 43 112 40 112 39 112 42 112 347 106 26 206 15 MATCHLINE FOR SECTION CUT @ PATIO EXPOSED BOARD FORMED CONC. WALL 28 28 28 28 28 28 28 28 28 28 Q MOTORIZED SHADE POCKETS INDICATED WITH DASHED LINE AND HATCH RE: RCP 10 A8.1 10 A8.1 6" / 12" 12 2 1/2" / 12" B.O. HEADER @ 8' - 8 1/8" B.O. HEADER @ 10' - 5 7/8" B.O. DOOR HEADER @ 8' - 8 1/8" B.O. HEADER @ 8' - 8 1/8" B.O. HEADER @ 10' - 5 7/8" W12X30 C12X20.7 W12X30 W12X35 10 A8.2 T.O. C-CHANNEL @ 23' - 0 1/2" A6.5 4 2' - 6 1/2" 8' - 0" (2) 4" EXHAUST VENTS AND (1) 7" EXHAUST VENT WITH STONE LOUVER. RE: MECH. PLANS. 6 A6.5 13' - 1" 3 A6.6 1' - 2 1/4" R.O. 9' - 11 1/2" AFF 1 3/4" 7" 5' - 1 3/4" R.O. 8' - 8 1/8" 5 5/8" 8' - 2 1/2" 10' - 4 1/8" 26 108 Q LIGHT @ WALL Q Q Q 25 108 25 206 27 206 27 206 Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 9/16/2016 10:33:42 AM A4.2 ELEVATIONS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 0' 2' 4' 8' 16' 1/4" = 1'-0" 1 SOUTH ELEVATION 2 Exterior South View - MOTORIZED SHADE ADDED No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16