Loading...
HomeMy WebLinkAboutB16-0031_A5.8_1480363080.pdfMAIN LEVEL FINISHED FLOOR 11' - 11 1/4" UPPER LEVEL FINISHED FLOOR 23' - 11 1/4" LOWER LEVEL FINISHED FLOOR 1' - 6 1/4" 1 A5.1 4 A5.5 1 A5.2 1 A5.3 1 A5.4 LINE OF EXISTING GRADE 1 A5.9 BEDROOM #4 207 STAIRS 213 MUDROOM 113 WET STORAGE 004 WINE RM. 003 AV EQUIP. RM. 012 CLOSET 101B MASTER CLOSET 102 OFFICE 216 SHOWER STAIR 116 CLOSET 217 BATHROOM #2 218 A6.11 3 A6.7 2 3 A8.1 4 A8.1 B.O. STRUCT. @ 10' - 6 5/8" AFF B.O. STRUCT. @ 7' - 0 1/8" ABOVE CONC. 1 2 3 4 5 6 7 8 9 10 11 12 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 15' - 0 1/2" 11 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" T.O. PLATE @ 11' - 9 3/4" T.O. PLATE @ 10' - 1" 4" / 12" 6" / 1 2" 2 1/2" / 12" T.O. PLATE @ 10' - 5 1/2" T.O. PLATE @ 12' - 5 1/2" T.O. CONC. 1' - 5 1/2" T.O. CONC. 3' - 7 1/4" 2' - 0" 4' - 0" B.O. HEADER @ 9' - 6 3/4" 2' - 6" 9 A6.7 A6.1 1 A6.4 3 A6.10 1 A6.1 3 5 A6.7 6 A6.9 2 A6.9 2 A8.2 1 A8.2 3 A8.2 4 A8.2 T.O. STL. BEAM @ 23' - 11 1/4" 1 A6.3 10' - 5" 12' - 0" T.O. PLATE @ 12' - 3 1/2" 7 3/8" 2" 8' - 2" 10" 32' - 8 3/4" 5 1/2" B.O. CEILING @ 9' - 5 7/8" AFF T.O. MAT SLAB @ 2 1/2" T.O. CONC. @ 3' - 3 1/4" 3' - 9 1/4" T.O. MAT SLAB @ 2' - 1 1/4" 4" B.O. HEADER @ 11' - 0 3/8" B.O. CELING @ 9' - 0" AFF W16X36 T.O. STL. BEAM @ 38' - 0 5/8" B.O. CEILING @ 9' - 6" AFF B.O. STRUCT. @ 9' - 1 3/8" AFF T.O. PLATE @ 9' - 9 1/8" T.O. TOPPING SLAB @ 7 1/4" W8X28 C12X20.7 W8X28 B.O. STRUCT. @ 11' - 4 1/2" AFF 6 " / 1 2 " T.O. TOPPING SLAB @ 2' - 3 1/4" T.O. TOPPING SLAB @ 2' - 3 1/4" 1/8" / 12" B.O. STRUCT. @ 10' - 9 1/8" AFF B.O. CEILING STRUCT. @ 9' - 1 1/8" AFF T.O. CONC. TO B.O. STRUCT. 9' - 2 1/8" 4" BATHROOM EXHAUST VENTS. RE: MECH. 6" / 12" Q Q W10X19 42 115 50 115 39 115 38 115 3 002 4 002 5 002 28 8 STRUCTURAL SLAB @ FRONT ENTRY. RE: STRUCT. SEE SHEETS A7.4 THROUGH A7.12 FOR STAIR INFORMATION. A6.11 4 T.O. CONC. @ 3' - 6 1/4" 1" STEP T.O. CONC. @ 11' - 6" T.O. CONC. LEDGE @ 7' - 3" 13 102B 13 102B 13 102B 13 102B 13 102B 13 102B 30 102 30 102 11 102 11 102 12 102 12 102 11 102 11 102 3 1/2" 6" / 12" 2' - 0" 31 102 31 102 3" 3 1/2" 2 A8.2 14 102B 14 102B 14 102B 14 102B 14 102B 14 102B SHADE POCKET SHOWN W/ HATCH. SHADE TO BE REGULAR ROLL TO HAVE SHADE CLOSER TO GLAZING C-CHANNEL ATTACHED TO WALL @ BOTH ENDS W/ (4) THREADED RODS WELDED TO STL. BEAM INSIDE WALL. RE: STRUCT (2) 3 1/2" X 3 1/2" SHADE POCKETS OVER FRONT ENTRY SIDELITES. POCKETS SHOWN W/ HATCH. RE: RCP DIMENSIONS SHOWN IN ELEVATION ARE MEASURED FROM FRAME TO FRAME. T.O. CONC. LEDGE @ 10' - 10 1/4" T.O. CONC. LEDGE @ 10' - 10 1/4" 28 28 WINE RM. 003 B.O. C-CHANNEL @ 11' - 0" AFF T.O. STL. BEAM @ 23' - 9 1/8" 23' - 9 1/4" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 9/16/2016 10:36:19 AM A5.8 BUILDING SECTIONS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1/4" = 1'-0" 1 Section 13 No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16