HomeMy WebLinkAboutB16-0031_A6.11_1480363140.pdfSYNTHETIC SHAKE ROOF RE: ELEVATIONS AND SPEC SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC 12 RE: ROOF PLAN T.O. BEAM RE: SECTIONS & STRUCT. WOOD BOX BEAM WRAPPED OVER STL. BEAM. SYNTHETIC SHAKE ROOF RIDGE CAP RE: SPEC. & ROOF MANUFACTURER RECOMMENDATIONS STEEL RIDGE BEAM RE: STRUCT. PROVIDE BLOCKING AS REQUIRED PER STRUCT. APPLIED WOOD RAFTERS RE: RCP AND SPEC 1X6 T&G DECKING SOFFIT W/ 1/8" X 1/8" REVEAL B.O. BEAM RE: SECTIONS & STRUCT. 9 1/2" R E : R C P RE: STRUCT. PROVIDE BLOCKING AS REQ'D 3/4" TYP. SYNTHETIC SHAKE ROOF RE: ELEVATIONS AND SPEC 5/8" PLYWOOD SHEATHING TYP. 6X10 RAFTERS LAG BOLTED FROM ABOVE IN TO WOOD RIDGE BEAM RE: STRUCT. 12 RE: ROOF PLAN T.O. BEAM RE: SECTIONS & STRUCT. WOOD BEAM SLEEVED OVER KNIFE PLATE SYNTHETIC SHAKE ROOF RIDGE CAP RE: SPEC. & ROOF MANUFACTURER RECOMMENDATIONS STL. RIDGE BEAM FROM INTERIOR CONTINUOUS TO CREATE STL. KNIFE PLATE. RE: STRUCT. 2X6 T&G DECKING SOFFIT 1' - 1 1/2" COPPER FLASHING CAP. RE: SPEC SEAT CUT RAFTERS AT RIDGE BEAM. RE: STRUCT. NOTCH WOOD RIDGE BEAM TO RECEIVE KNIFE PLATE. RE: STRUCT. BLOCKING AS REQ'D STL. PLATE WELDED TO MODIFIED STL. RIDGE BEAM RE: STRUCT. LINE OF MODIFIED STL. RIDGE BEAM BEYOND. THROUGH-BOLTS COUNTER SUNK AND PLUGGED RE: STRUCT. LVL RIDGE BEAM RE: STRUCTURAL 11 7/8" WOOD I-JOIST WITH BLOWN IN INSULATION RE: STRUCT JOIST HANGERS RE: STRUCTURAL TYP. ROOF ASSEMBLY SEE 3/A6.11 T.O. BEAM RE: SECTIONS & STRUCT. SYNTHETIC SHAKE ROOF RIDGE CAP @ SYNTHETIC SHAKE ROOF. RE: SPEC. RE: ROOF MANUF. RECOMMENDATIONS SYNTHETIC SHAKE ROOF RE: ELEVATIONS AND SPEC 11 7/8" 1 1 7 /8" STANDING SEAM METAL ROOF RE: ELEVATIONS AND SPEC 5/8" PLYWOOD SHEATHING 14" WOOD I-JOIST @ 16" O.C. WITH BLOWN IN INSULATION RE: STRUCT./SPEC. VYCOR ICE AND WATER SHIELD (USE HIGH TEMPERATURE AT ALL METAL ROOFS) - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE RE: SPEC 6 1/8" RIGID INSULATION PANEL WITH 5/8" PLYWOOD SHEATHING GLUED TO 5 1/2" CONTINUOUS RIGID FOAM INSULATION PANEL R-25 +/- RE: SPEC. SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC 12 RE: ROOF PLAN T.O. BEAM RE: SECTIONS & STRUCT. WOOD BOX BEAM WRAPPED OVER STL. BEAM. METAL RIDGE CAP RE: SPEC. & ROOF MANUFACTURER RECOMMENDATIONS STEEL RIDGE BEAM RE: STRUCT. PROVIDE BLOCKING AS REQUIRED PER STRUCT. FILL CAVITY W/ BLOWN-IN INSULATION RE: SPEC APPLIED WOOD RAFTERS RE: RCP AND SPEC 1X6 T&G DECKING SOFFIT W/ 1/8" X 1/8" REVEAL B.O. BEAM RE: SECTIONS & STRUCT. 9 1/2" RE: R CP RE:STRUCT.1' - 2"2X10'S RIPPED TO SIZE PROVIDE BLOCKING AS REQ'D 3/4" 2X6 DOUG-FIR T&G DECKING STANDING SEAM METAL ROOF RE: SPEC AND ELEVATIONS 2X2 TUBE STEEL PURLINS PAINTED TO MATCH WINDOW COLOR. RE: SPEC 5/8" PLYWOOD OVER 1X SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR MONOPOINT LIGHT FIXTURES RE: RCP W6X12 BENT STEEL RAFTERS RE: STRUCTURAL METAL RIDGE CAP RE: SPEC AND ROOF MANUFACTURER RECOMMENDATIONS. W6X12 BENT STEEL RAFTERS. RE: STRUCT. DRIP FLASHING OVER 2X10 FASCIA TYPICAL STANDING SEAM METAL ROOF ASSEMBLY @ FRONT ENTRY RE: 7 / A6.10 W8X28 STEEL BEAM RE: STRUCTURAL AND RCP HSS 3X3X1/4 W/BEVELED COLUMN TOP WELD TO B.O. STEEL RAFTERS AND T.O. STEEL BEAM 2X2 TUBE STEEL PURLINS PAINTED TO MATCH WINDOW COLOR. RE: SPEC 1" MIN. 10" 6" 1' - 1 5/8" DRIP EDGE FLASHING STANDING SEAM METAL ROOF RE: SPEC AND ELEVATIONS 2X6 DOUG-FIR T&G DECKING ROOFS TO BE PROTECTED THROUGHOUT WITH SNOW CLIPS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: SPEC W8X28 STEEL BEAM RE: RCP AND STRUCT. T.O. STEEL BEAM RE: STRUCT. W6X12 BENT STEEL RAFTERS RE: STRUCTURAL 3X3 TUBE STEEL COLUMN WELDED TO STEEL BEAM 8" L X 8" W X 1/2" T STEEL PLATE WELDS TO COLUMN ABOVE AND KNIFE PLATE BELOW KNIFE PLATE WITH THROUGH BOLTS RE: STRUCT. 10 X10 TIMBER COLUMN HSS 3X3X1/4 BEVELED COLUMN TOP WELDED TO B.O. STEEL RAFTER AND T.O. STEEL BEAM 5/8" PLYWOOD OVER 1X SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR MONOPOINT LIGHT FIXTURES RE: RCP 8" 2X2 TUBE STEEL PURLINS PAINTED TO MATCH WINDOW COLOR. RE: SPEC 1" 3 1/2" TYP. 2" GRID LINE 6X10 WOOD BARGE RAFTER RE: ELEVATIONS AND STRUCTURAL FOR LOCATION AND LAYOUT. PROVIDE SEAT CUT AT SHOULDER BEAM AND RIDGE BEAM RE: ELEVATIONS. 2X4 BLOCKING RE: ROOF PLAN WORKING POINT COPPER FLASHING CAP WITH DRIP EDGE RE: SPEC 3/4" TYP. SYNTHETIC SHAKE ROOF RE: SPEC AND ELEVATIONS * PROVIDE WOOD SIDING @ SIM. DETAIL CALLOUT NOTE 6" WOOD BOX BEAM WRAPPED OVER STL. BEAM RE: SPEC. STEEL RIDGE BEAM RE: STRUCT. WOOD OUTLOOK BEAM BOLTED TO STEEL BEAM RE: STRUCT AND ELEVATION FOR SIZE. 3 A6.11 2 A6.11 1 1/2" Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 9/16/2016 10:37:53 AM A6.11 ROOF DETAILS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 1 1/2" = 1'-0" 3 ROOF RIDGE DETAIL @ DROPPED STEEL BEAM 1 1/2" = 1'-0" 2 TYPICAL EXTERIOR ROOF RIDGE DETAIL 1 1/2" = 1'-0" 4 ROOF RIDGE @ FLUSH LVL RIDGE BEAM 1 1/2" = 1'-0" 1 ROOF RIDGE DETAIL @ LIVING ROOM 3" = 1'-0" 5 ROOF RIDGE @ FRONT ENTRY ROOF 1 1/2" = 1'-0" 6 ROOF RAKE @ FRONT ENTRY 1 1/2" = 1'-0" 7 ROOF EAVE @ FRONT ENTRY 1 1/2" = 1'-0" 8 ROOF RAKE @ DROPPED WOOD RIDGE BEAM No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16