HomeMy WebLinkAboutB16-0031_A6.7_1480363560.pdfTYPICAL STONE VENEER ASSEMBLY
SEE 1/A6.1
(5) 2X6 POST RE:
STRUCT
1/2" STEEL PLATE LAG
BOLTED TO 5 1/2" PSL
POST RE: STRUCT
4"
2"
3"
1' - 2"
1"
7"
8X8 WOOD STRUT W/ KNIFE
PLATE CONNECTION TO WALL
W/ SURFACE MOUNTED THRU-
BOLTS RE: STRUCT
4"2' - 5 3/4"
3 3/4"
1' - 4"
5 1/8" 1' - 2 1/4"
& ELEV.
RE: SECTIONS
LINE OF KNIFE PLATE INSIDE
WOOD STRUT
*NOTE - KNIFE PLATE IS SHOWN
DIAGRAMMATICALLY RE: STRUCT
FOR ACTUAL KNIFE SIZES AND
REQUIRED BOLT PATTERN
WRAP KNIFE PLATE W/ICE AND WATER
SHIELD WITHIN DEPTH OF STONE TO SEAL
JOINTS BETWEEN AIR AND WATER
INFILTRATION BARRIER AND KNIFE PLATE.
PROVIDE SEALANT JOINT BETWEEN STONE
AND KNIFE PLATE. PAINT KNIFE PLATE TO
MATCH WINDOW COLOR.
GRID
LINE
TYPICAL WOOD SIDING ASSEMBLY
11 1/16" 1' - 2"
1 3/4"
TYPICAL WOOD SIDING
ASSEMBLY
(5) 2X6 POST RE:
STRUCT
3/8" STEEL PLATE LAG
BOLTED TO (5) 2X6 POST
RE: STRUCT
4"
3"
1/2"
8X8 WOOD STRUT W/ KNIFE
PLATE CONNECTION TO WALL
W/ SURFACE MOUNTED THRU-
BOLTS RE: STRUCT
4"
1' - 4"
LINE OF KNIFE PLATE INSIDE
WOOD STRUT
*NOTE - KNIFE PLATE IS
SHOWN DIAGRAMMATICALLY
RE: STRUCT FOR ACTUAL
KNIFE SIZES AND REQUIRED
BOLT PATTERN
& ELEV.
RE: SECTIONS
WRAP KNIFE PLATE W/ICE AND
WATER SHIELD FOR 3/4" DEPTH OF
SIDING. PROVIDE SEALANT JOINT
BETWEEN WOOD AND KNIFE PLATE -
PAINT KNIFE PLATE TO MATCH
WINDOW COLOR
2" SOLID BLOCKING
BEHIND STEEL PLATE.
CONCRETE SLAB OR TOP OF CONCRETE WALL
STEEL BASE PLATE RE: STRUCT.
EXPANSION BOLT BASE PLATE TO CONC.
HSS COLUMN WELDED TO TOP AND
BOTTOM STEEL PLATES RE:
STRUCT.
8" X 8" STEEL BASE PLATE RE: STRUCT.
KNIFE PLATE RE: STRUCT.
COUNTERSUNK THROUGH BOLTS
10 X 10 DOUG FIR COLUMN
KNIFE PLATE RE: STRUCT.
COUNTERSUNK THROUGH BOLTS
8" X 8" STEEL BASE PLATE RE: STRUCT.
3X3 HSS COLUMN WELDED I-BEAM
ABOVE AND PLATE BELOW RE:
STRUCT.
WEB STIFFENER RE: STRUCT.
I-BEAM RE STRUCT.
1/2" EXT. GRADE PLYWOOD
SHEATHING RE: STRUCT.
5/8" GWB
APPROX. 2" THICK CUT STONE
CAP WITH TOP SLOPED MIN
10%. EXTENDS BEYOND FACE
OF STONE APPROX. 1"
2X FRAMING RE: STRUCT
INTERIOR
EXTERIOR
TYP. STONE VENEER WALL
ASSEMBLY SEE 1/A6.1
GRID
LINE
VERTICAL WOOD SIDING WALL
ASSEMBLY SEE 8/A6.6
3D DRAINAGE MEDIUM AND AIR
INFILTRATION BARRIER LAPS
OVER FLASHING ABOVE STONE
FLASHING EXTENDS UP BEHIND AIR
INFILTRATION BARRIER MIN. 4", AND
EXTENDS OUT OVER STONE OUT
MIN. 3"
INTERIOR
EXTERIOR
TYPICAL COPPER SHINGLE SIDING ASSEMBLY
SEE 12/A6.6
TYPICAL STONE VENEER WALL
ASSEMBLY NOTE: DO NOT LET
COPPER TOUCH STONE VENEER
IN-FILL CORNER UP TO TEMPORARY 1X4
TO CREATE STRAIGHT EDGE FOR
COPPER PANEL SIDING INSTALLATION
MIN. 1/4" SEALANT JOINT BTW COPPER SHINGLE
AND GROUT USE SANDED CAULK TO MATCH
MORTAR
2 3/8"
1X BLOCKING TO ALIGN STONE AND
THEN REMOVED FOR SHINGLE INSTALL
INTERIOR
EXTERIOR
TYPICAL COPPER SHINGLE SIDING ASSEMBLY
SEE 12/A6.6
TYPICAL STONE VENEER WALL ASSEMBLY
SEE 1/A6.1
IN-FILL UP TO TEMPORARY 1X4 W/
GROUT TO CREATE STRAIGHT EDGE
FOR COPPER PANEL SIDING
INSTALLATION
1/4" SEALANT JOINT BTW COPPER
SIDING AND GROUT
*SIM NOTE INDICATES STONE TO
WOOD SIDING TRANSITION
1X BLOCKING TO ALIGN STONE AND
THEN REMOVED FOR SHINGLE INSTALL
1"
INTERIOR
INTERIOR
EXTERIOR
2X6 P.T. BLOCKING @ CORNER
SELF-ADHERING ICE AND WATER
SHIELD TYPE FLASHING TO
SEPARATE WOOD AND STONE
VENEER
TEMPORARY 1/4" MASONITE TO BE
REMOVED AFTER STONE VENEER
INSTALLATION. APPLY CONC. FOR
RELEASE AGENT OR SIMILAR
PRODUCT TO MASONITE TO
FACILITATE ITS REMOVAL
CAULK JOINT ONCE 1/4" MASONITE
IS REMOVED
WOOD SIDING
RE: ELEVATION FOR TYPE
TYP. STONE VENEER ASSEMBLY
2X FINISH TRIM
SEE 9/A6.6 FOR TYP. WOOD
SIDING WALL ASSEMBLY AND
ELEVATIONS
INTERIOR
EXTERIOR
2x4 RECLAIMED WOOD
CORNER TRIM W/
MITERED CORNER RE:
ELEVATIONS
CORNER BLOCKING RE:
STRUCT
GRID
LINE
DRAINAGE MEDIUM
AND AIR FILTER
FABRIC LAPS OVER
FLASHING
V-PUNCH FROM GUTTER CRIMP TOOL
BUTYL RUBBER SEALANT CAULK
SONNEBORN ELASTIC
ADHESIVE ONLY @ EDGE
OF PLYWOOD PANEL
PREFINISHED ALUMINUM CLAD
PANELING TO MATCH WINDOWS.
PANEL WRAPS 3/4" PLYWOOD PANEL
SET IN BUTYL CAULK JOINT AND
HELD BY V-PUNCH AND SONNEBORN
ADHESIVE. METAL TO MATCH
WINDOW COLOR
FINISHED FLOOR RE: PLANS
3/4" T&G PLYWOOD RE: STRUCT.
11 7/8" WOOD I-JOISTS @ 16" O.C. RE: STRUCT.
INSULATION RE: SPEC & COVER SHEET
1X6 T&G DECKING W/ 1/8" X 1/8"
REVEAL BTW BOARDS RE: RCP
T.O. PLYWOOD
RE: SECTIONS / PLANS
INTERIOR
EXTERIOR
EXTERIOR
RIM JOIST RE: STRUCT.
GRID
LINE
VERTICAL WOOD SIDING
SEE 7/A6.4
3D DRAINAGE MEDIUM OVER AIR & WATER
INFILTRATION BARRIER LAPS OVER ICE &
WATER SHIELD & FLASHING
PFSM FLASHING RE: SPEC
TURN UP WALL 6" MIN.
C10X15.3 C-CHANNEL TRIM 1/2"
2 1/4"
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
As indicated
9/16/2016
10:37:39 AM
A6.7
DETAILS
CWF
HB
REIMERS
RESIDENCE
03/01/2016
3090
BOOTH
CREEK DR. VAIL, CO
CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0" 1
STRUT DETAIL @ STONE VENEER
1 1/2" = 1'-0"
2
STRUT DETAIL @ WOOD SIDING
1 1/2" = 1'-0"
3
TYP. COLUMN TO BEAM CONNECTION
1 1/2" = 1'-0"
5
WALL DETAIL @ STONE TO WOOD
SIDING TRANSITION
3" = 1'-0"
6
STONE VENEER AND COPPER SHINGLE
@ CORNER TRANSITION
3" = 1'-0"
4
STONE VENEER AND COPPER SHINGLE
TRANSITION
3" = 1'-0"
7
STONE VENEER AND WOOD SIDING
CONNECTION @ CORNER
3" = 1'-0"
8
HORIZONTAL WOOD SIDING CORNER
DETAIL
6" = 1'-0" 10
PRE-FINISHED ALUMINUM CLAD PANEL
@ HORIZONTAL AND VERTICAL SEAM
1 1/2" = 1'-0" 9
FLOOR DETAIL @ KITCHEN PANTRY
No. Revision Date
Revision
Description
1 APRIL 26, 2016 ASI #1
5 AUGUST 12,
2016
ASI #5
11/28/16