HomeMy WebLinkAboutB16-0031_A8.2_1480363260.pdfEXTERIOR INTERIOR W8X28 STL BEAM @ FRONT ENTRY SUPPORT WELDED TO C-CHANNEL. POWDER COAT ENTIRE ENTRY ROOF ASSEMBLY TOGETHER RE: STRUCT. REMOVEABLE WOOD TRIM TO ACCESS MOTORIZED SHADE POCKET LINE OF WINDOW JAMB BEYOND WINDOW SET OVER SEALANT BED SEALANT IN-FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ. C12X20.7 STL. C-CHANNEL ATTACHED W/ THREAD STL ROD WELDED TO W- SECTION BEAM WEB RE: STRUCT GRID D 7" 4 5/8" 1/4" PLYWOOD PLATE 2X PLATE 1/4" PLYWOOD PLATE W8X18 STL. BEAM RE: STRUCT. 2 1/4" 6 7/8" 3/4" 5/8" 5 1/2" 3 1/2" 2 3/8" 1" 6 1/4" 2" IN-FILL STL. BEAM WEB W/ SOLID BLOCKING THREAD STL ROD WELDED TO W- SECTION BEAM WEB 4 1/2" LINE OF STUD WALL BEYOND 1 1/2" 6" 2 3/4" 3 1/2" EXTERIOR INTERIOR TRANSOM WINDOW ABOVE FRONT DOORS RE: WINDOW SCHEDULE AND ELEVATIONS WINDOW HEAD SECTION ICE & WATER SHIELD CONTINUOUS UNDER SILL @ UPPER WINDOW LAPS OVER WINDOW NAILING FLANGE SEALANT 7/8" (1) 1 3/4" X 3.5" LVL MICROLAMS RIPPED 1/2" 1/2" PLYWOOD FILLER ATTACHED TO DOOR FRAME SIDE OF HEAD ONLY CUSTOM 3/4" WOOD TRIM CUSTOM 4/4" WOOD JAMB EXTENSION 3/16" 5" 3/16" 3/4" REMOVABLE WOOD TRIM 3 1/2" IN-FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ'D PFSM CLAD PANEL RE: ELEVATIONS 3 1/4" 5 3/8" 3 7/8" 1" 3 5/8" 3 7/8" 1" LINE OF VERTICVAL TRIM BETWEEN WINDOWS BEYOND 2 A8.2 4 5/8" 1 5/8" 3/8" 4 A8.2 SIDELITE WINDOW NEXT TO FRONT DOOR RE: WINDOW SCHEDULE AND ELEVATIONS IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING HEADER RE: STRUCT. TYPICAL WOOD TRIM TO LAP OVER T.O SHADE VALANCE SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 2X BLOCKING WINDOW @ BRIDGE ABOVE FRONT ENTRY RE: WINDOW SCHEDULE ROLLER SHADE LUTRON 100 SHOWN RE: RCP REMOVABLE 3/4" TRIM COPPER SHINGLE SIDING RE: SPEC AND ELEVS FOR LOCATION LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN AND CONT. UP WALL EXTERIOR 8 3/8" INTERIOR 5 1/4" 3" 2 3/8" 4 3/4" B.O. HEADER RE: ELEVATIONS 6 1/4" 11 5/8" 1' - 0 1/8" 1' - 0 1/8" 1/4" 2" 1/4" 2 1/4" EXTERIOR INTERIOR W8X13 STEEL HEADER RE: STRUCT WOOD TRIM LINE OF WINDOW JAMB BEYOND ICE & WATER SHIELD CONTINUOUS UNDER SILL SEALANT IN-FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ. STL. C12X20.7-CHANNEL RE: STRUCT GRID LINE LINE OF 1 3/4" X 5 1/2" LVL SUPPORT BTWN WINDOWS 3" 5 1/2" 1" 3 1/2" 3" REMOVABLE PANEL FOR SHADE ACCESS SIDE MOUNT MOTORIZED ROLLER SHADE WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 1' - 0" LUTRON SHADE FROM WINDOW ABOVE EXTERIOR INTERIOR (1) 1 3/4" X 7.5" LVL MICROLAMS WOOD TRIM WINDOW JAMB BEYOND ICE & WATER SHIELD CONTINUOUS UNDER SILL @ UPPER WINDOW LAPS OVER DOOR FRAME SEALANT 3/8" GRID LINE IN-FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ. 7/8" 3" PFSM CLAD PANEL RE:ELEVATIONS 5" 3/16" 3/16" 1 5/8" 2 5/8" 3/8" 1 1/8" 1 1/4" 3 1/4" 7 3/8" EXTERIOR INTERIOR (1) 1 3/4" X 5.5" LVL MICROLAMS 3/4" WOOD TRIM SEALANT GRID LINE SPRAY FOAM VOID & SHIM AS REQ. 3/4" WOOD JAMB EXTENSION W/ WOOD TRIM PFSM CLAD PANEL RE: ELEVATIONS 3 1/4" 3/16" 5" 3/16" 3" 3 1/2" 3 7/8" 2 1/4" EXTERIOR INTERIOR (1) 1 3/4" X 5.5" LVL MICROLAMS 3/4" WOOD TRIM RE: SPEC SEALANT 3/8" GRID LINE 1/2" PLYWOOD FILLER ATTACHED TO DOOR FRAME SIDE OF HEAD ONLY CUSTOM 4/4 WOOD JAMB EXTENSION 3/16" 5" 3/16" IN-FILL W/ EXPANDING SPRAY FOAM INSULATION & SHIM ALUMINUM CLAD PANEL 3 1/2" 3 1/2" 3/4" 3 1/4" 3/8" 9/16" X 9/16" WOOD TRIM PROVIDE WEEP TYPICAL WINDOW HEADER @ STONE VENEER. SEE 1/A8.1 IN-FILL W/ SPRAY FOAM EXPANDING INSULATION AND SHIM AS REQ'D RE: SPEC PFSM FLASHING EXTERIOR HEADER RE: STRUCT. TYPICAL WOOD TRIM TO LAP OVER T.O SHADE VALANCE SIDE MOUNT MOTORIZED ROLLER SHADE W/ EXTRUDED ALUMINUM LUTRON HOUSING WRAPPED IN WOOD PER SPEC. LUTRON 100 DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS WITH SHADE MANUFACTURER RE: RCP 2X BLOCKING WINDOW RE: WINDOW SCHEDULE ROLLER SHADE W/ REVERSE ROLL TO AVOID CONFLICTS WITH WINDOW HANDLE GRID LINE INTERIOR REMOVABLE 3/4" TRIM TYP. STONE VENEER ASSEMBLY SEE 1/A6.1 5 1/4" LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 5" B.O. HEADER RE: ELEVATIONS BRONZE METAL PANEL IN PLACE OF GLAZING ("MAPE" PANEL) RE: SPEC. 2X FRAMING ON INTERIOR OF LOWER WINDOW PANEL. IN-FILL BEHIND "MAPE" PANEL WITH BLOWN-IN CELLULOSE INSULATION W10X15 STL. BEAM RE: STRUCT. 4 3/4" 5 5/8" WINDOW RE: WINDOW SCHEDULE SPRAY IN EXPANDING FOAM INSULATION AND SHIM AS REQ'D INTERIOR EXTERIOR LAP ICE AND WATER SHIELD OVER SHEATHING AND OVER NAILING FLANGE. MAKE CONTINUOUS BETWEEN WHEN WINDOWS SEALANT JOINT AND BACKER ROD ALUMINUM CLAD PANELS AT CORNER TO MATCH WINDOW RE: ELEVATIONS 3/4" TRIM MATERIAL PROVIDE MITER LOCK JOINT 6X6 DOUR-FIR WOOD COLUMN OR STEEL COLUMN RE: STRUCT. 5 1/2" 5 1/2" SILL - 1" JAMB EXTENSION EXTEND 1/4" BEYOND APRON TRIM 3" GRID TO R.O. 5 7/8" GRID TO R.O. 5 7/8" GRID LINE GRID LINE CUSTOM JAMB EXTENSION WINDOW RE: WINDOW SCHEDULE LAP WATERPROOF MEMBRANE LAPS OVER NAILING FLANGE AND UNDER WINDOW SILL FACTORY MUL-CAP BETWEEN WINDOW AND DOOR GRID LINE CUSTOM WOOD JAMB EXTENSION INTERIOR EXTERIOR CONTINUOUS VERTICAL (2) 2X8 POST RIPPED TO 7" - W/ FACE OF 2X8 3 1/2" PAST GRID LINE INFILL W/ SPRAY FOAM INSULATION AND SHIM AS REQ'D PATIO DOOR RE: WINDOW SCHEDULE 3 1/2" 3/8" 3" 3/8" CUSTOM 3/4" WOOD TRIM 3/16" 5" 3/16" 5 3/8" 3 3/4" WINDOW RE: WINDOW SCHEDULE LAP WATERPROOF MEMBRANE LAPS OVER NAILING FLANGEs FACTORY MUL-CAP BETWEEN WINDOW AND DOOR GRID LINE CUSTOM WOOD JAMB EXTENSION INTERIOR EXTERIOR CONTINUOUS VERTICAL 1 3/4" X 5 1/2" LVL INFILL W/ SPRAY FOAM INSULATION AND SHIM AS REQ'D WINDOW RE: WINDOW SCHEDULE 2 7/8" 4 7/16" 3/16" 4 1/16" 3/16" CUSTOM 3/4" WOOD TRIM 2" WINDOW RE: WINDOW SCHEDULE LAP WATERPROOF MEMBRANE LAPS OVER NAILING FLANGE AND UNDER WINDOW SILL FACTORY MUL-CAP BETWEEN WINDOW AND DOOR GRID LINE CUSTOM WOOD JAMB EXTENSION INTERIOR EXTERIOR CONTINUOUS VERTICAL TUBE STEEL COLUMN - W/ FACE OF 2X6 3 1/2" PAST GRID LINE INFILL W/ SPRAY FOAM INSULATION AND SHIM AS REQ'D PATIO DOOR RE: WINDOW SCHEDULE 3 3/8" CUSTOM 3/4" WOOD TRIM 3/16" 5 13/16" 3/16" 6 3/16" 3 1/2" 4" 3 1/2" SIM NOTE INDICATES STEEL COLUMN REPLACED W/ (2) 2X8 POST RIPPED TO 7" 2" LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR WINDOW RE: WINDOW SCHEDULE LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE CUSTOM WOOD JAMB PER EXTENDED WIDTH LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE TRIM PER INTERIOR DOCUMENTS GRID TO R.O. 6 1/2" PFSM CLAD PANEL SIDING RE: ELEVATIONS SEALANT JOINT AND BACKER ROD INTERIOR HSS 4X4X1/4 TUBE STL. COLUMN RE: STRUCT. BLOCKING AS REQ'D Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 3" = 1'-0" 9/16/2016 10:39:38 AM A8.2 WINDOW AND DOOR DETAILS CWF HB REIMERS RESIDENCE 03/01/2016 3090 BOOTH CREEK DR. VAIL, CO CONSTRUCTION DOCUMENTS 3" = 1'-0" 1 SHADE DETIAL @ FRONT ENTRY TRANSOM 3" = 1'-0" 9 WINDOW HEADER TO WINDOW SILL CONNECTION @ STAIR 3" = 1'-0" 3 DOOR HEADER TO WINDOW SILL @ FRONT ENTRY 3" = 1'-0" 4 DOOR JAMB TO WINDOW JAMB @ FRONT ENTRY 3" = 1'-0" 2 WINDOW JAMB TO WINDOW JAMB CONNECTION AT FRONT ENTRY 3" = 1'-0" 7 WINDOW DETAIL @ MAPE PANEL 3" = 1'-0" 6 WINDOW CORNER DETAIL @ ALUMINUM PANEL SIDING 3" = 1'-0" 10 WINDOW JAMB TO DOOR JAMB DETAIL 3" = 1'-0" 8 WINDOW JAMB TO WINDOW JAMB DETAIL @ LVL STRUCTURE 3" = 1'-0" 11 WINDOW JAMB TO WINDOW JAMB DETAIL @ STEEL COLUMN 3" = 1'-0" 5 WINDOW JAMB DETAIL @ LOWER LEVEL PATIO CORNER - MOTORIZED SHADE ADDED - C-CHANNEL SIZE INCREASED - CONNECTION @ C-CHANNEL ADDED No. Revision Date Revision Description 1 APRIL 26, 2016 ASI #1 5 AUGUST 12, 2016 ASI #5 11/28/16