Loading...
HomeMy WebLinkAboutcut sheets_13.pdfl\NIGHP WALL-MOUNT ijOILER UIMENSIONS AND :::>PEUFICATIONS BOTTOM N055 55 11 95.0 51 44 33-1/4' 18-1/2" 16" l -WHN085 -35---v-95.0---,-9 ----~--33-V4' 18-1/2" 16' t r---w-·--Wil-tffio--iTu-·--22-95.0---·-102--·-39---33-1/4' 1s-1/2" 1r 1· --r-r---159----- ~:~~==~=-~---{f.~--=--~*--==-~== !~~~ :~:~ :~ 16-3/4' 'H/4' 3-1/4' B/4' 16-1/2" 1' -:~ ::1/4' ~:--~ =--:~ == ·wilN285 ___ 285----~----9ro---264----22;--n-114' 1s-1!2" 1r 1+112" 11-3/4" r r 1-114" 16-3/4'4=°3!4' 3-V4'-2-:Ji.fi"WT_1ff_i-114' r -y·-·-i34-- ~-~ ®-~=~--==:_)4.4 ____ lf..C:~ nS:= 35-112" 1S 21-314' 11-112" 12-112" 9-114' 9-112" 2-114' 21-112" r 1H14" _4' 2Hll 3-3!4' _3Pf' 1-17f:::_f~=:~t=-_.?.~=--= Notes: Indoor installation only. All information subject to change. Change 'N" to 'L •for LP gas models. *WHN399 value is Thermal Efficiency SMART SYSTEM™ FEATURES STANDARD FEATURES ----- > SMART SYSTEM Digit.al Operating Control Multi-Color Graphic LCD Display with Navigation Dial and Soft Keys > Three Boller Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization > Built-in Cascading Sequencer for up to 8 Boilers Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability with Copper Fin II > Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers Night Setback DHW Night Setback* Anti-Cycling Outdoor Air Reset Curve Ramp Delay Boost Temperature & TI me >Three Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Pump Control* Domestic Hot Water Pump > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the Smart System DHW Modulation limiting Separately Adjustable Space Heat/DHW Switching Times* > Building Management System Integration 0-10 VOC Input to Control Modulation or Set Point 0-10 VDC Modulation Rate Output 0-10 VOC Input to Enable/Disable call for heat I _, 1 l) ~-~-1 JLl t Y~r, Lt" HIGH EFFICIENCY BOILERS & WATER HEATERS >Access to BMS Settings through Graphic LCD Display >High-Voltage Terminal Strip 120 VAC / 60 Hertz/ 1 Phase Power Supply Three Sets of Pump Contacts > Low Volt.age Terminal Strip 24 VAC Device Relay Proving Switch Contacts Row Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input* 0-10 VDC Signal to Control Variable Speed Boiler Pump* Modbus Contacts >Time Clock > Oat.a Lofting Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts >Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder > Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters Lucn1nva1, m Patent Pending ~00 f,1,iddccx Sirnp r-:ir• !·.t, lo:"ban;__•n, TE-lli',f;'>r~t- P· o tt:..3[:9.{NO{: ~-o1C: r,,,,-1 ·Y· 11 t::.l mi C Lochinvar.com GY STAR Most Efficient Recognltion1 OE AFUE Efficlencyf lating Burner with 5:1 Tumdown Direct-Spark Ignition Low-NOx Operation Field Convertible from Natural to LP Gas > ASME St.ainless Steel Heat Exchanger 30 psi ASME Relief Valve >Vertical & Horizont.al Direct-Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet > Smart System Control > Condensate Trap > Other Features Automatic Reset High limit Adjustable High limit w/Manual Reset Boiler Circulating Pump Wall-Mount Bracket Zero Clearances to Combustible Materials 12-Year limited Warranty (See Warranty for Details) 5-Year Parts Warranty OPTIONAL EQUIPMENT CON·X·US Remote Connectivity Modbus Communication Row Switch Low-Water Cutoffw/Manual Reset & Test Alarm Bell Concentric Vent Kit Condensate Neutralization Kit BMS Gateway to LON or BacNet Multi-Temperature loop Control Sidewall Vent Termination Floor Stand Wireless Outdoor Sensor FIRING (ODES > M9 Standard Construction > M7 California Code *Exclusive feature, available only from Lochinvar § WHN 55-285 only