Loading...
HomeMy WebLinkAboutB17-0209_A000_1500067080.pdfWH WH 1 A5.01 1 A5.11 SHEET NUMBER DRAWING NUMBER SHEET NUMBER DRAWING NUMBER SHEET NUMBER DRAWING NUMBER BUILDING SECTION IDENTIFICATION WALL SECTION IDENTIFICATION 1 A9.01 SHEET NUMBER DRAWING NUMBER DETAIL IDENTIFICATION INTERIOR ELEVATION IDENTIFICATION 1 A6.01 SHEET NUMBER DRAWING NUMBER ENLARGED DETAIL IDENTIFICATION AREA OF DRAWING TO BE ENLARGED SECTION MATERIAL GRAPHICS 23A 76H PARTITION TYPE; RE: PARTITION TYPE SCHEDULE PARTITION TYPE; RE: PARTITION TYPE SCHEDULE PARTITION TYPE IDENTIFICATION ACOUSTICAL PARTITION TYPE IDENTIFICATION 308 DOOR NUMBER DOOR IDENTIFICATION ROOM NAME 314 876.00 SF ROOM NUMBER ROOM/SPACE/AREA IDENTIFICATION ROOM NAME ROOM AREA A 1 COLUMN LETTER COLUMN LETTER COLUMN REFERENCE GUIDE STRUCTURAL GRID ELEVATION LEVEL NAME BATT INSULATION CONCRETE UNDISTURBED OR COMPACTED EARTH POROUS FILL (GRAVEL) STEEL ALUMINUM MASONRY - BRICK MASONRY - CONCRETE BLOCK RIDGID INSULATION GYPSUM PLASTER PLYWOOD FINISH WOOD EXTERIOR ELEVATION IDENTIFICATION 1 A4.01 A7.01 99 99 99 99 C1 WINDOW TYPE SHEET NUMBER DRAWING NUMBER ? WINDOW IDENTIFICATION KEYNOTE IDENTIFICATION NOTE NUMBER 001 ASI REVISION IDENTIFICATION REVISION NUMBER REVISION DESCRIPTION ELEVATION DATUM IDENTIFICATION MASTER BATH BATH 1 PANEL BOX MASTER BEDROOM BEDROOM 1 LIVING MUD ROOM SKI STORAGE BEDROOM 2 BEDROOM 3 BATH 2 BATH 3 SEE THROUGH FIREPLACE (TC WS54ST) VENTED THOUGH EXISTING CHIMNEY CHASE TV W/D K K Q TT TV TV TV TV KING HEADBOARD KITCHEN PANTRY DW F LOUNGE BAR / BUFFET 3' - 0" CL L L GRAPHIC STANDARDS OWNER STEVE & LAURIE SCHNITZLEIN 4 FLANDERS VALLEY CT SKILLMAN, NJ 08558 P:732.616.8121 F:FAX ELECTRICAL NELSON ELECTRIC 4033 WILDRIDGE ROAD AVON CO 81620 P:970.748.8890 F:FAX ARCHITECT KH WEBB ARCHITECTS 710 WEST LIONSHEAD CIRCLE, UNIT A VAIL CO 81657 P:970.477.2990 F:970.477.2965 CONTRACTOR ALLEMAN CONSTRUCTION, LLC PO BOX 4088 GYPSUM CO 81637 P:970.376.0890 F:FAX PROJECT TEAM Sheet # Sheet Name XX/XX/XX 50%SD XX/XX/XX 100%SD XX/XX/XX 50%DD XX/XX/XX 100%DD XX/XX/XX 50%CD CIVIL C1.0 PLACEHOLDER LANDSCAPE L1.01 PLACEHOLDER ARCHITECTURE A000 COVER SHEET A100 UNIT 512 EXISTING / PROPOSED PLAN A100A UNIT 512 EXISTING / PROPOSED RCP A250 LIVING / KITCHEN A251 MASTER BED / BATH A252 BEDROOM / BATHROOM #1 A253 BEDROOM / BATHROOM #2 A254 BEDROOM / BATHROOM #3 A300 BUILDING SECTIONS A900 AXONOMETRIC VIEWS A901 AXONOMETRIC VIEWS STRUCTURAL S2.01 PLACEHOLDER PLUMBING P1.01 PLACEHOLDER MECHANICAL M1.01 PLACEHOLDER ELECTRICAL E1.01 PLACEHOLDER Project number Date Drawn by 6/20/2017 3:39:48 PM A000 COVER SHEET 000000 VAIL SPA - UNIT 512 REMODEL SCHNITZLEIN RESIDENCE 6.20.2017 JNS PROJECT SUMMARY CODE: IBC 2015 ZONING: HIGH DENSITY MULTIPLE FAMILY DISTRICT OCCUPANCY CLASSIFICATION: TYPE R-2 CONSTRUCTION CLASSIFICATION: TYPE II-A BUILDING FULLY SPRINKLED WITH AUTOMATIC ALARM SYSYEM VAIL SPA UNIT 512 REMODEL PERMIT SET UPDATE 06.12.2017 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON- DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON- DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. GENERAL NOTES: No. Description Date VICINITY MAP - 30" X 8" VENT LOUVER ABOVE DOOR FOR MAKE UP AIR - RELOCATE WASHER DRAIN FROM EXISTING LOCATION 07/14/17