HomeMy WebLinkAboutB17-0209_A000_1500067080.pdfWH
WH
1
A5.01
1
A5.11
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
BUILDING SECTION IDENTIFICATION
WALL SECTION IDENTIFICATION
1
A9.01 SHEET NUMBER
DRAWING NUMBER
DETAIL IDENTIFICATION
INTERIOR ELEVATION IDENTIFICATION
1
A6.01 SHEET NUMBER
DRAWING NUMBER
ENLARGED DETAIL IDENTIFICATION
AREA OF DRAWING TO
BE ENLARGED
SECTION MATERIAL
GRAPHICS
23A
76H
PARTITION TYPE; RE:
PARTITION TYPE SCHEDULE
PARTITION TYPE; RE:
PARTITION TYPE SCHEDULE
PARTITION TYPE IDENTIFICATION
ACOUSTICAL PARTITION TYPE IDENTIFICATION
308 DOOR NUMBER
DOOR IDENTIFICATION
ROOM NAME
314
876.00 SF
ROOM NUMBER
ROOM/SPACE/AREA IDENTIFICATION
ROOM NAME
ROOM AREA
A
1
COLUMN LETTER
COLUMN LETTER
COLUMN REFERENCE
GUIDE
STRUCTURAL GRID
ELEVATION
LEVEL NAME
BATT INSULATION
CONCRETE
UNDISTURBED OR
COMPACTED EARTH
POROUS FILL
(GRAVEL)
STEEL
ALUMINUM
MASONRY - BRICK
MASONRY -
CONCRETE BLOCK
RIDGID INSULATION
GYPSUM PLASTER
PLYWOOD
FINISH WOOD
EXTERIOR ELEVATION IDENTIFICATION
1
A4.01
A7.01
99
99
99
99
C1 WINDOW TYPE
SHEET NUMBER
DRAWING NUMBER
?
WINDOW IDENTIFICATION
KEYNOTE IDENTIFICATION
NOTE NUMBER
001
ASI
REVISION IDENTIFICATION
REVISION NUMBER
REVISION DESCRIPTION
ELEVATION DATUM IDENTIFICATION
MASTER
BATH
BATH 1
PANEL
BOX
MASTER
BEDROOM
BEDROOM 1 LIVING
MUD ROOM
SKI STORAGE
BEDROOM 2
BEDROOM 3
BATH 2
BATH 3
SEE THROUGH
FIREPLACE
(TC WS54ST)
VENTED THOUGH
EXISTING CHIMNEY CHASE
TV
W/D
K
K
Q
TT
TV
TV
TV
TV
KING HEADBOARD
KITCHEN
PANTRY
DW
F
LOUNGE
BAR / BUFFET
3' - 0"
CL
L
L
GRAPHIC STANDARDS
OWNER
STEVE & LAURIE SCHNITZLEIN
4 FLANDERS VALLEY CT
SKILLMAN, NJ 08558
P:732.616.8121
F:FAX
ELECTRICAL
NELSON ELECTRIC
4033 WILDRIDGE ROAD
AVON CO 81620
P:970.748.8890
F:FAX
ARCHITECT
KH WEBB ARCHITECTS
710 WEST LIONSHEAD CIRCLE, UNIT A
VAIL CO 81657
P:970.477.2990
F:970.477.2965
CONTRACTOR
ALLEMAN CONSTRUCTION, LLC
PO BOX 4088
GYPSUM CO 81637
P:970.376.0890
F:FAX
PROJECT TEAM
Sheet # Sheet Name
XX/XX/XX 50%SD
XX/XX/XX 100%SD
XX/XX/XX 50%DD
XX/XX/XX 100%DD
XX/XX/XX 50%CD
CIVIL
C1.0 PLACEHOLDER
LANDSCAPE
L1.01 PLACEHOLDER
ARCHITECTURE
A000 COVER SHEET
A100 UNIT 512 EXISTING / PROPOSED PLAN
A100A UNIT 512 EXISTING / PROPOSED RCP
A250 LIVING / KITCHEN
A251 MASTER BED / BATH
A252 BEDROOM / BATHROOM #1
A253 BEDROOM / BATHROOM #2
A254 BEDROOM / BATHROOM #3
A300 BUILDING SECTIONS
A900 AXONOMETRIC VIEWS
A901 AXONOMETRIC VIEWS
STRUCTURAL
S2.01 PLACEHOLDER
PLUMBING
P1.01 PLACEHOLDER
MECHANICAL
M1.01 PLACEHOLDER
ELECTRICAL
E1.01 PLACEHOLDER
Project number
Date
Drawn by
6/20/2017 3:39:48 PM
A000
COVER SHEET
000000
VAIL SPA - UNIT 512
REMODEL
SCHNITZLEIN
RESIDENCE
6.20.2017
JNS
PROJECT SUMMARY
CODE:
IBC 2015
ZONING:
HIGH DENSITY MULTIPLE FAMILY DISTRICT
OCCUPANCY CLASSIFICATION:
TYPE R-2
CONSTRUCTION CLASSIFICATION:
TYPE II-A
BUILDING FULLY SPRINKLED WITH
AUTOMATIC ALARM SYSYEM
VAIL SPA UNIT 512 REMODEL
PERMIT SET UPDATE 06.12.2017
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS
PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS.
NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE
DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY
RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS
BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR
AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF
STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS
OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE
TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL
PLATES OR BEAMS UNLESS OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND
CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING
AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES,
CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE
BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO
DOOR SCHEDULE FOR DOOR TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO
WINDOW SCHEDULE FOR WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO
FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH
ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS
NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY
ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE
ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT
SHALL NOT CONSTITUTE A DELAY IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS
AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE
INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL
RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE
CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES
NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND
ALL LOCAL AND REGIONAL CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL
FIELD COORDINATE AND OBTAIN APPROVALS FROM THE
ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR
DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL
FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY
AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING
GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER
AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER
CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED
REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL
PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE
WITH ARCHITECT'S WRITTEN APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT
THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE
ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT,
ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED
STANDARDS OF THE INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE
AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS.
NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE
LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE
LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO
THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF
EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL
VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF
DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-
DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF
DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-
DISTURBED LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS
ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE
DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS.
THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR
LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT.
GENERAL NOTES:
No. Description Date
VICINITY MAP
- 30" X 8" VENT LOUVER
ABOVE DOOR FOR MAKE UP AIR
- RELOCATE WASHER DRAIN
FROM EXISTING LOCATION
07/14/17