Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0209_A300_1500067080.pdf
5 4 2 3 4 6 3 5 1 4 5 1 3 4 2 2 3 3 2 1 17 18 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 NONBEARING WALL RATING - 1 HR. (BASE ON UL DESIGN NO. U448) 1. FLOOR & CEILING RUNNERS (NOT SHOWN) 2 1/2" x 1 3/8" OR 3 5/8" x 1 1/4" 2. STEEL STUDS 2 1/2" x 1 3/8" OR 3 1/2" x 1 1/4", 24" O.C. 3. BATTS & BLANKETS 4. GYPSUM BOARD - 12" THICK, 4' WIDE 5. JOINT TAPE AND COMPOUND (2" WIDE) NONBEARING WALL RATING - 2 HR. (BASE ON UL DESIGN NO. U453) 1. STEEL STUDS 3 1/2" x 1 1/4", 24" O.C. 2. FLOOR & CEILING RUNNERS (NOT SHOWN) 3 5/8" x 1 1/4" 3. RESILIENT CHANNEL - 25 MSG GALV STEEL (VERTICALLY SPACED MAX 24" O.C.) 4. BATTS & BLANKETS (3" MIN.) 5. GYPSUM BOARD - 12" THICK, 4' WIDE 6. JOINT TAPE AND COMPOUND (2" WIDE) THROUGH-PENETRATION FIRESTOP SYSTEM FLOOR MOUNTED WATER CLOSET - 3 HR. (BASE ON UL DESIGN NO. F-A-2072) 1. FLOOR ASSEMBLY - STEEL FLOOR AND FORM UNITS 2. FIRESTOP DEVICE 3. CLOSET FLANGE 4. DRAIN PIPING 5. WATER CLOSET (NOT SHOWN) THROUGH-PENETRATION FIRESTOP SYSTEM EXHAUST VENT - 2 HR. (BASE ON UL DESIGN NO. F-A-1029) 1. FLOOR ASSEMBLY -STEEL FLOOR AND FORM UNITS 2. THROUGH-PENETRATION -CONDUIT NOM 6" (OR SMALLER) RIGID STEEL CONDUIT 3. FILL, VOID OR CAVITY MATERIAL - SEALANT - MIN 12" THICKNESS OF FILL MATERIAL APPLIED W/IN THE ANNULUS, FLUSH W/ TOP SURFACE OF FLOOR ROOF/ CEILING ASSEMBLY - 1HR. (BASE ON UL DESIGN NO. P510) 1. ROOF COVERING - HOT MOPPED APPLICATION MATERIAL 2. ROOF INSULAION - 2" FIBER BOARD 3. SHEATHING MATERIAL - VAPOR BARRIER 4. GYPSUM BOARD 5. STEEL ROOF DECK - 1 1/2" THICK 6. ADHESIVE 7. STEEL JOINTS 8. BRIDGING - STEEL ANGLES 9. COLD ROLLED CHANNELS - MIN. .053" THICK 10. HANGER WIRE 11. AIR DUCT - MIN. ..034" THICK GALV STEEL 12. DAMPER - MIN. .056" THICK GALV STEEL, 16" BY 16" PROTECTED ON BOTH SURFACES WITH 1/16" THICK CERAMIC FIBER PAPER AND HELD OPEN WITH FUSIBLE LINK 13. FIXTURES, RECESSED LIGHT - UL LISTED, STEEL HOUSING, WIRED PER NATIONAL ELECTRIC CODE 14. FIXTURE PROTECTION - UL CLASSIFIED R25019 FF109 FIRE RATED RECESSED LIGHT COVER 15. STEEL FRAMING MEMBERS 16. GYPSUM BOARD - 1/2" FOR 1 HR. RATING 17. METAL TRIM MOLDING 18. DRYWALL SCREW - TYPE S-12, 1 " LONG, SELF DRILLING AND SELF TAPPING, .163" THREAD DIA HEADS Project number Date Drawn by 5/31/2017 4:26:10 PM A300 BUILDING SECTIONS 000000 VAIL SPA - UNIT 512 REMODEL SCHNITZLEIN RESIDENCE 5.31.2017 Author 3" = 1'-0" 1 WALL TYPE - 1HR 3" = 1'-0" 2 WALL TYPE - 2HR 3" = 1'-0" 3 FLOOR MOUNTED WATER CLOSET 3" = 1'-0" 4 EXHAUST VENT 3" = 1'-0" 5 ROOF / CEILING ASSEMBLY No. Description Date 07/14/17