Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB16-0463_A0.00 1795_1481151916.pdf
olti OF 10,4,1 46; 2 ell ri- IS IT igid eh. o SHASTA RESIDENCE 11701 111°1i DRB APPROVED 11/2/2016 12:00:00 AM ti 1795 WEST GORE CREEK DRIVE , VAIL, CO 81657 MATERIAL SYMBOLS : ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: GENERAL AND SITE R o 11 HI HI A0.00 COVER b ui U EARTH // // PLYWOOD ABV ABOVE L LENGTH I` t 11 HI III01 DO NOT SCALE DRAWINGS TOPOGRAPHIC SURVEY m AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH o r AP ACCESS PANEL LT LIGHT TROUGH ° L o POROUS FILL/DRAINAGE �f .-% FINISH WOOD AC ACOUSTICAL LTL LINTEL 02 VERIFY ALL DIMENSIONS, CONDITIONS AND UTILITY LOCATIONS ON A1 .01 SITE PLAN 0 ADD ADDENDUM LVR LOUVER THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING q ADJ ADJACENT MH MANHOLE ANY MATERIALS. nOTIFY ARCHITECT OF ANY CONFLICTS OR L1 .01 LANDSCAPE PLAN E ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. ii ii ���//////% STONE MASONRY WOOD-ROUGH ALUM ALUMINUM MO MASONRY OPENING 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY 0 ARCH ARCHITECT (URAL) MTL METAL BSMT BASEMENT MAX MAXIMUM RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE DRAWING INDEX: ARCHITECTURAL CONSTRUCTION CONTINUES IN THOSE AREAS. E BRG BEARING MECH MECHANIC (AL) l BVL BEVELED MC MEDICINE CABINET A2.00 GRFA/SITE COVERAGE CALCULATIONSXt.' f) STRUCTURAL CONCRETE BLOCKING 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, v BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE BLK BLOCK M METER (5) TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR A2.01 LOWER LEVEL PLAN IIIIIC 1.110 BLKG BLOCKING MM MILLIMETER (S) BEAMS UNLESS OTHERWISE NOTED. A2.02 MAIN LEVEL PLAN �_ 0 0 N. CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM BLDG BUILDING MIR MIRROR 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. A2.03 UPPER LEVEL PLAN zc CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL _N 0 CSMT CASEMENT MULL MULLION MOUNTED FIXTURES,TOILETS, TOILET ACCESSORIES, CABINETRY, A2.04 ROOF PLAN W m BATT INSULATION C CAULK (ING) NAT NATURAL COUNTERTOPS, SHELVES AND CLOSET RODS. CliQ 7 7 CLG CEILING NR NOISE REDUCTION A3.00 BASEMENT CREDIT ELEVATIONS CT CERAMIC IC TILE NOMINCONTRACT NOT NOMINAL06 O DNOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER CLR CLEAR A3.01 BUILDING ELEVATION I TO DOOR SCHEDULE FOR DOOR TYPES. RIGID INSULATION COD CARBON MONOXIDE DETECTOR NTS NOT TO SCALE COL COLUMN OPG OPENING 07 O DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR A3.02 BUILDING ELEVATION CONC CONCRETE OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. A3.03 BUILDING ELEVATION CMU CONCRETE MASONRY UNIT OPH OPPOSITE HAND 1/ // I A3.04 BUILDING ELEVATION STEEL/METAL AS NOTED CONST CONSTRUCTION OH OVERHEAD CONT CONTINUOUS PR PAIR 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT CJT CONTROL JOINT PK PARKING WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH A4.01 BUILDING SECTION CPR COPPER PVMT PAVEMENT CARPET CUST CUSTOM PL PLASTIC LAMINATE ARCHITECT. A4.02 BUILDING SECTION 1.1.1 11111111 DT DRAPERY TROUGH PT POINT DTL DETAIL PSF POUNDS PER SQUARE FOOT 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY A4.03 BUILDING SECTION DIM DIMENSION PSI POUNDS PER SQUARE INCH THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS DR DOOR PL PROPERTY LINE PROJECT,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE A4.04 BUILDING SECTIONa DRW DRAWING QT QUARRY TILE ARCHITECT. DF DRINKING FOUNTAIN REF REFERENCE A4.05 BUILDING SECTION 1 Alk ELEC ELECTRIC (AL) REF REFRIGERATOR 10THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL A5.01 WINDOW DETAILSZ EL ELEVATION (5) REIN REINFORCE (D), (ING) o A4.00 A4.00 APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED EELEVATOR REQ REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL A6.01 EXTERIOR DETAILS o EQQ EQUAL RES RESILIENT Q EXH EXHAUST REV REVISION (D), (ING) BUILDING CODE, 2003 EDITION. CODE COMPLIANCE IS CC BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVERSE MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT A6.02 EXTERIOR DETAILS 01111 . EXT EXTERIOR RH RIGHT HAND WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES A6.03 EXTERIOR DETAILS o FOC FACE OF CONCRETE R RISER INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES. Q 61 0 FOF FACE OF FINISH R&S ROD AND SHELF DRAWING INDEX: LIGHTING � J FOM FACE OF MASONRY RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN - 1 ( 1 FOS FACE OF STUDS RDT RECESSED DRAPERY TRACK APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY N Q FIN FINISH (ED) RFG ROOFING CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE E2.01 LOWER LEVEL PLAN afin > A4.00 `� A4.00FFE FINISHED FLOOR ELEVATION RM ROOM CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS ? WFE FIRE EXTINGUISHER RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. EZ.OZ MAIN LEVEL PLAN 3 ) FDC FIRE DEPARTMENT CONNECTION R/S ROUGH SAWN DETAIL REFERENCE DETAIL REFERENCE FHC FIRE HOSE CONNECTION S SEALANT (EXTERIOR) E2.03 UPPER LEVEL PLAN la Q FEC FIRE EXTINGUISHER CABINET SHTG SHEATHING N FP FIREPLACE SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE W W MAIN 1 FPS FIREPROOFING, SPRAYED SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT W 100' 0" A4.00 FLG FLASHING SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. u. V FLR FLOOR (ING) SIM SIMILAR W FD FLOOR DRAIN SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE 0 HEIGHT REFERENCE FTG FOOTING SPEC SPECIFICATON (5) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, a W SECTION REFERENCE FND FOUNDATION SQ SQUARE MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC.TO OBTAIN j 0 FBO FURNISHED BY OTHERS STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE ; 0 ^"^fie-n FPHB FREEZE PROOF HOSE BIB ST STAIN INDUSTRY. H FUR FURRED (ING) STL STEEL J ~ ROOM NAME GA GAGE, GAUGE SD STORM DRAIN Q W GALV GALVANIZED STR STRUCTURAL 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING > GC GENERAL CONTRACT (OR) TEL TELEPHONE EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 3 A GL GLASS, GLAZING TV TELEVISION N 0I REVISION REFERENCE ROOM NAME GYP GYPSUM BOARD THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. h HB HOSE BIB T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND 4 r HDW HARDWARE TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. HDR HEADER TOS TOP OF STEEL HTG HEATING TOW TOP OF WALL GRID W11 HVAC HEATING/VENTILATING/AC TB TOWEL BAR HT HEIGHT TR TRANSOM PROJECT SUMMARY. HC HOLLOW CORE T TREAD GRID BUBBLE WALL TYPE REFERENCE HM HOLLOW METAL TYP TYPICALfin HOR HORIZONTAL UNO UNLESS NOTED OTHERWISE Code: HWH HOT WATER HEATER VB VAPOR BARRIER International Residential Code 2012 1 INCL INCLUDE (D), (ING) VIF VERIFY IN FIELD Occupancy: One-Family Dwelling ID INSIDE DIAMETER VERT VERTICAL IBCINSTALLED BY CONTRACTOR VCT VINYL COMPOSITION Separations: A8. 2 1 Hour (residence/garage) 4 11 IBO INSTALLED BY OWNER WC WATER CLOSET INS INSULATE (D), (ION) WP WATER PROOFING 1 Hour (residence/mechanical) 3 INT INTERIOR WWF WELDED WIRE FABRIC JC JANITOR'S CLOSET W WIDTH, WIDE Special Attributes: INTERIOR ELEVATION REFERENCE WINDOW TAG KIT KITCHEN WDW WINDOW Intelligent Addressable Fire Alarm ISSUED FOR: DATE: LAM LAMINATE (D) WO WITHOUT Automatic Sprinkler System LAV LAVATORY WD WOOD SCHEMATIC DESIGN 6.16.16 LH LEFT HAND FINAL DRB 10.10.16 ® STN---/--TILE DOOR TAG MATERIAL BREAK COPY RIGHT RESERVATION The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's service for use solely with respect to this Project and, unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain,without limitation, all common law, statutory and other reversed rights, includingthe copyright hereof. Noperson,whether © ALL MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. having come rightly into possession hereof or otherwise, shall employ these documents on any other project, nor SCALE: for additions to this Project nor for the completion of this DRAWN: MDS Project by others, unless with the prior express written ARCHITECT. consent of the Architect and upon appropriate compensation to the Architect in an amount and kind PROJECT#: 1605 SUMAN ARCHITECTS satisfactory to the Architect. The Architect expressly SHEET TITLE: COVER SHEET P.O. Box 7760 claims all proprietary rights in the material which is issued AVON, COLORADO 81620 in confidence for design and/or construction purposes of 970.479.7502 this Project as noted. These materials may not be CONTACT: MICHAEL SUMAN copied, modified, nor employed in any way without the EMAIL: michael@sumanarchitects.com specific prior written consent and permission of the Architect. AOIOO ©2014 Michael Suman Architect, LLC. All rights reserved.