HomeMy WebLinkAboutSubmittal Binder.pdf M-SERIES SUBMITTAL DATA: MXZ-4C36NA2 MITSUBISHI MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M ELECTRIC Job Name: System Reference: Date: � �alllllllllllllllllllllim��,, �� ,dllllllllllllllllllllllllllllllllllllllil �� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII� 14 iIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIP' 1` ..,1411111111111101""IIIpDi"' Outdoor Unit:MXZ-4C36NA2 ACCESSORIES o 3/8"x 1/2"Port Adapter(MAC-A454JP) o 1/2"x 3/8"Port Adapter(MAC-A455JP) o 1/2"x 5/8"Port Adapter(MAC-A456JP) o 1/4"x 3/8"Port Adapter(PAC-493PI) o 3/8"x 5/8"Port Adapter(PAC-SG76RJ) o M-NETAdapter(PAC-IFO1MNT-E) o Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-4C36NA2 Rated Capacity Btu/h 35,400/34,400 Cooling* Capacity Range Btu/h 12,600-36,400/12,600-34,800 (Non-ducted/Ducted) Rated Total Input W 3,760/3,940 Rated Capacity Btu/h 36,000/34,400 Heating at 47°F* Capacity Range Btu/h 11,400-43,000/11,400-41,400 (Non-ducted/Ducted) Rated Total Input W 3,020/3,100 Heating at 17°F* Rated Capacity Btu/h 22,200/20,300 (Non-ducted/Ducted) Rated Total Input W 3,340/3,450 Power Supply Voltage,Phase, Hertz I 208/230V, 1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Cooling 54 Sound Pressure Level Heating dB(A) 56 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 139(63) External Finish I Munsell 3.0Y 7.8/1.1 Refrigerant Pipe Size O.D.— Liquid(High Pressure) 1/4(12.7) Eight Ports Gas(Low Pressure) In(mm) A: 1/2(6.35);B,C,D:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method M ■ Flared/Flared Refrigerant R410A JIM *Rating Conditions per AHRI Standard: Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB Heating at 17°F I Indoor:70°F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/23.9°C(75°F)WB Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: MXZ-4C36NA2, contd. OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP COP @ 47°F @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted 19.2 9.4 11.0 3.50 2.67 Heating 5 to 65°F(-15 to 18°C)WB Ducted and 17.6 9.05 10.4 3.38 2.61 Non-ducted Ducted 16.0 8.7 9.8 3.25 2.54 NOTES: • Minimum of two Indoor Units must be connected to the MXZ-4C36NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: MXZ-4C36NA2 Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8" v Intake III Rear Air 2-13/16' 4-19 32' 2-U Sha.ed Notched Hole 2-1/32' (Foundation Bolt M101 3/32' 1111 MEM iN MIZIMpin Side kr Intake.* 1. 1 N Lii 6-01-5/16'Oran Hole Si rn b uisrhorge "' 113/32' 13/32" 1-1/32' 2-87/8'knackauf hole 2-(15/32'x1-13/32')Oval Hole 1-1/2' I (Connectin. wire hole) (Foundation Bolt M10) 1-5/8' II 3-e7/8'punched hole 37-13/32" - 31/32' 13' 19/32" II (Connecting wire hole) I� !Ir u ,®' Handle i 1, I Handle'° iii I+anale �� -0�� i� i ---g I I mfr •` 1h123/4 Air Intake — -4. r IO s�� �� �i -=-w I IO - 0'/�1° it 4 ens}0eV 0 I!L_J U1® US1 i®•���• c • Z{; GAS}U__ n.r J °�—ul , 't . _ _ ' 1-11/32' 14-7/32 1.FREE SPACE a E E 3-15/16' or more I I a�I+, 8„ 3-15/16" or more 13-25/32' or more e w rgnu mn1.I Conduit plates 2.SERVICE SPACE °1� 1p j Conduit connector U'.i ,, y11je '� MEM 3-15/16' or more SERVICE SPACE Lock nut 13-25/32' or mor- 13-25/32' or more A MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ANIMP NMN id CEaRTIFIED,.www. c E 1 I us ONIsrySmall XP Isre Mel SimOs0210210 FORM#MXZ-4C36NA2 for Multiple Indoor Unit Styles-201605 ti . Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SUBMITTAL DATA: SLZ-KAO9NA & SUZ-KAO9NA M-SERIES 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS /`MITSUBISHI ELECTRIC Job Name: System Reference: Date: ENERGY STAR® Yes -,; ---- ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. li 11 Eflio 1 Electrical Requirements 1„01'-- 1 11 Power Supply 208/230V, 1-Phase,60 Hz `� 11 Recommended Fuse/Breaker Size 15 A 11 1 Voltage - 11 Indoor-Outdoor S1-S2 AC 208/230V 1 — Indoor-Outdoor S2-S3 DC±24V Indoor Unit:SLZ-KAO9NA Outdoor Unit:SUZ-KAO9NA OPERATING CONDITIONS Indoor Intake Air Outdoor Intake Air GENERAL FEATURES Temp. Temp. • Four-way 2'x2'ceiling-cassette indoor unit for ceiling recessed 90°F(32°C)DB applications Maximum 73°F(23°C)WB 115°F(46°C)DB • Built-in drain mechanism for condensate removal;lifts to 19-11/16” Cooling' 3 67°F 19°C • Wide air-flow pattern for better air distribution Minimum ( )DB 14°F(-10°C)DB • Design features ventilation air intake knockout 57°F(14°C)WB • Long-life air filter included with indoor unit 80°F(27°C)DB 75°F(24°C)DB Maximum • Indoor unit powered from outdoor unit using A-Control 67°F(19°C)WB 65°F(18°C)WB • Choice of fan speed:Low,Medium,High Heating 70°F(21°C)DB -4°F(-20°C)DB • Automatic restart following a power outage Minimum 60°F(16°C)WB -5°F(-21°C)WBS • Limited warranty:five years parts and seven years compressors 'Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. ACCESSORIES s System cuts out at-9°F(-27°C)to avoid thermistor error and automatically restarts at-4°F(-20°C). Indoor Unit o Condensate Pump(BlueDiamond X87-711/721; 115/230V) o Condensate Pump(Sauermann SI30-115/230;115/230V) Indoor Unit o Grille(SLP-15AAUW;required-shipped with unit) MCA 1 A Fan Motor Output 15 W Outdoor Unit Fan Motor(ECM) 0.23 F.L.A. o Three-pole Disconnect Switch(TAZ-MS303) Airflow(Lo-Med-Hi) 280-320-350 Dry CFM o Air Outlet Guide(MAC-889SG) 250-290-320 Wet CFM o Mounting Base(DSD-400P) Air Filter Polypropylene Honeycomb o Mounting Pad(ULTRILITE1) Sound Pressure Level(Lo-Med-Hi) 29-32-38 dB(A) o Wall Mounting Bracket(QSWB2000M-1) DIMENSIONS UNIT INCHES/MM GRILLE INCHES/MM W 22-7/16/570 25-5/8/650 Controller Options D 22-7/16/570 25-5/8/650 o Wireless Controller(MHK1) ,H 9-1/4/235 13/16/20 o Wired Remote Controller(PAR-32MAA-J) o Wireless Interface for kumo cloud TM (PAC-WHSO1 WF-E) Weight(Unit/Grille) o Thermostat Interface(PAC-US444CN-1) Lbs. 36/7 o Hand-held Wireless Remote Controller kg 16.5/3 (PAR-FL32MA;req.PAR-FA32MA-E) External Finish(Unit/Grille) Galvanized-steel Sheets/ o Wireless Signal Receiver Module PAR-FA32MA Munsell 6.4Y 8.9/0.4 (for PAR-FL32MA-E) Field Drainpipe Size O.D. 1-1/4"/32 mm SPECIFICATIONS Outdoor Unit Cooling' Compressor DC Inverter-driven Rated Capacity 8,400 Btu/h MCA 12 A Minimum to Maximum Capacity Range 3,100-10,900 Btu/h MOCP 15 A SEER 15.0 Btu/h/W Fan Motor(ECM) 0.50 F.L.A. EER 12.0 Btu/h/W Sound Pressure Level Total Input 700 W Cooling 46 dB(A) Heating at 47°F2 Heating 50 dB(A) Rated Capacity 10,900 Btu/h DIMENSIONS INCHES/MM Minimum to Maximum Capacity Range 3,100-14,100 Btu/h W 31-1/2/800 HSPF 9 6 Btu/h/W COP 3 44 D 11-1/4/285 Total Input 930 W H 21-5/8/550 Heating at 17°F3 Rated Capacity 6,200 Btu/h Weight 66 lbs./30 kg Rated Total Input 740 W External Finish Munsell No.3Y 7.8/1.1 COP 2 46 Refrigerant Type R410A Maximum Capacity°° 6,200 Btu/h Refrigerant Pipe Size O.D. Maximum Total Input 1,040 W Gas Side 3/8"/9.52 mm Liquid Side 1/4"/6.35 mm 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB' Max.Refrigerant Pipe Length 65'/19 m 'Cooling I Outdoor:95°F(35°C)DB/75°F(24°C)WB" Max.Refrigerant Pipe Height Difference 40'/12 m 2 Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB* Connection Method Flared 2 Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB* 3 Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)WB' 3 Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB* Rating Conditions per AHRI Standard -Maximum Capacity is at full speed and performance for INVERTER-driven System. Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: SLZ-KAO9NA Unit : inch (mm) • 1 M Fresh air I Detail drawing of fresh air intake intake y I $3-15/16($100) 125 N o �� / 3-X1/802.8) Cut out hole ) c \ 20-7/81530) / _ \Suspensiop bolt pitch/ Burring hole 1 U o �E� a= ( co r- <D N g - - ---------7f.------------ I 1 o , II, \ M 7 g /' i .\ M n o M . \ N ° I .- N N �� ) NM in .22-7/16570) \ v � p co / \ - A N 4 . 1 . 414 i � (71 M a,./ / TN. I coN M Ceiling surface N • \ !1 l-- ) v I c.s N I7-27/32(199) r 7 N CO 13-27/32(352) N N 13-3/16(335) 19/32-1-15/32(15-37) 22-11/16-24-13/32(576-620) Ceiling hole 19/32-1-15/32(15-37) Drain pipe Wiring entry ccO"o 21/32(17) 7-15/16 202 9-1/16 230 VP-25 connection N Refrigerant (O.D.¢1-1/4032)) ,., pipe gas) I-- Suspension bolt M10 or W3/8 1111II m 1 Fi N L71 I r I r M ��i lei w — — M '— ✓ _i r_ a i = "`+5.co 2 Terminal block Grille +� N cl Ceiling surface N N N go co Q .N O) (0p in- c., W Cd - N N O.d + N -• 9 Models Refrigerent pipe Refrigerent pipe ,n 25-19/32(650) (liquid) (gas) 11-27/32(301) 1/4 inch 3/8 inch e? Air outlet hole Brand label SLZ-KAO9NA (0 6.35mm) (0 9.52mm) ta r ,../Grille flared connection flared connection • I :C/10-� ter' Drain hole 1/4 inch 3/8 inch M• 1 m C SLZ-KAl2NA (0 6.35mm) (¢9.52mm) N ;CaAuto vane flared connection flared connection — 1/4 inch 1/2 inch o R 0 SLZ-KA15NA (0 6.35mm) (0 12.7mm) to ',71-= o M t flared connection flared connection N N. N N MM —,__�,_,_,__._._._.__._._._.__._._._ M cn ci 0 N N C L6 •- O 7.- N Q Q MMI ro I _t —_---2(_.Air intake grille —Vane motor 14-27/32(377) , Air intake hole 1-3/8(35) , 2-5/32(55) Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: SUZ-KAO9NA < 15-3/4 > Drain hole q31-5/8 •71- Unit: inch c? ,7 Air in V RIR tom, K F Av 1 M co N Air in + Bi N A A 1-9/16 Air out 2-3/8 x 1 3/1 6 Oval hole 7/8>1 29/32 11-1/4 17/32 1 handle I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII0.1 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII co IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ^ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 'RI coN IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ,, n � I�1 Gas Liquid pipe :1/4:3/8(f(flared)lared)(KA09/12) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII -; �.I pipe VV V 1 - �� ,r,V •_=_ 1/2 (flared)(KA15) Mn 11-29/32 6-23/32 co 5-15/16 19-11/16 < X > 31-1/2 2-23/32 < > < REQUIRED SPACE Basically open 4 inch or more without any obstruction in front and on both sides of the unit. 4 o'co 0,e 4vr. 4/nor shore • F 4/ CO°Ce P Or, h. Open two sides of left,ft right, or rear side. MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com rut CEgRTIFIED,• c E 1 I us mss a°b"z, .TEo FORM#SLZ-KAO9NA-SUZ-KAO9NA- 201604 —m.a,a.a,.m.n.u.,.— W. Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SUBMITTAL DATA: SLZ-KAl2NA & SUZ-KAl2NA M-SERIES 12,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS /`MITSUBISHI ELECTRIC Job Name: System Reference: Date: ENERGY STAR® Yes ,�-- ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. I„ I i Electrical Requirements 114 Power Supply Recommended Fuse/Breaker Size 208/230V, 1-Phase,60 Hz � I 15 A ItVoltage 1 Indoor-Outdoor S1-S2 AC 208/230V � m 1 _____— ±24 Indoor-Outdoor S2-S3 DC±24V ` Indoor Unit SLZ-KAl2NA Outdoor Unit:SUZ-KAl2NA OPERATING CONDITIONS Indoor Intake Air Outdoor Intake Air Temp. Temp. Maximum 90°F(32°C)DB 115°F(46°C)DB GENERAL FEATURES Cooling4 73°F(23°C)WB • Four-way 2'x2'ceiling-cassette indoor unit for ceiling recessed Minimum 67°F(19°C)DB 14°F(-10°C)DB applications 57°F(14°C)WB • Built-in drain mechanism for condensate removal;lifts to 19-11/16" 80°F(27°C)DB 75°F(24°C)DB • Wide air-flow pattern for better air distribution Maximum 67°F(19°C)WB 65°F(18°C)WB • Design features ventilation air intake knockout Heating 70°F(21°C)DB -4°F(-20°C)DB • Long-life air filter included with indoor unit Minimum 60°F(16°C)WB -5°F(-21°C)WBS • Indoor unit powered from outdoor unit using A-Control • Choice of fan speed:Low,Medium,High °Applications should be restricted to comfort cooling only;equipment cooling applications are not • Automatic restart following a power outage recommended for low ambient temperature conditions. • Limited warranty:five years parts and seven years compressors s System cuts out at-9°F(-27°C)to avoid thermistor error and automatically restarts at-4°F(-20°C). ACCESSORIES Indoor Unit Indoor Unit o Condensate Pump(BlueDiamond X87-711/721; 115/230V) MCA 1 A o Condensate Pump(Sauermann SI30-115/230;115/230V) Fan Motor Output 20 W o Grille(SLP-15AAUW;required-shipped with unit) Fan Motor(ECM) 0.28 F.L.A. Airflow(Lo-Med-Hi) 280-320-390 Dry CFM Outdoor Unit 250-290-350 Wet CFM Air Filter Polypropylene Honeycomb ❑ Three-pole Disconnect Switch(TAZ-MS303) Sound Pressure Level(Lo-Med-Hi) 30-34-39 dB(A) o Air Outlet Guide(MAC-889SG) ❑ Mounting Base(DSD-400P) GRILLE o Mounting Pad(ULTRILITE1) DIMENSIONS UNIT INCHES/MM INCHES/MM o Wall Mounting Bracket(QSWB2000M-1) W 22-7/16/570 25-5/8/650 Controller Options D 22-7/16/570 25-5/8/650 o Wireless Controller(MHK1) H 9-1/4/235 13/16/20 o Wired Remote Controller(PAR-32MAA-J) o Wireless Interface for kumo cloud TM (PAC-WHSO1WF-E) Weight(Unit/Grille) o Thermostat Interface(PAC-US444CN-1) Lbs. 36/7 o Hand-held Wireless Remote Controller kg 16.5/3 (PAR-FL32MA;req.PAR-FA32MA-E) External Finish(Unit/Grille) Galvanized-steel Sheets/ o Wireless Signal Receiver Module PAR-FA32MA Munsell1-1/4"/326.4Y/ mm /0.4 (for PAR-FL32MA-E) Field Drainpipe Size O.D. 1 SPECIFICATIONS Outdoor Unit Cooling' Compressor DC Inverter-driven Rated Capacity 11,100 Btu/h MCA 12A Minimum to Maximum Capacity Range 3,400-13,300 Btu/h MOCP 15 A SEER 15.4 Btu/h/W Fan Motor(ECM) 0.50 F.L.A. EER 12.0 Btu/h/W Sound Pressure Level Total Input 920 W Cooling 49 dB(A) Heating at 47°F2 Heating 51 dB(A) Rated Capacity 13,600 Btu/h Minimum to Maximum Capacity Range 3,100-17,100 Btu/h HSPF 9 6 Btu/h/W DIMENSIONS INCHES/MM COP 3 38 W 31-1/2/800 Total Input 1,180 W D 11-1/4/285 Heating at 17°F3 H 21-5/8/550 Rated Capacity 8,300 Btu/h Rated Total Input 930 W COP 2 62 Weight 77 lbs./35 kg Maximum Capacity" 8,300 Btu/h External Finish Munsell No.3Y 7.8/1.1 Maximum Total Input 1,310 W Refrigerant Type R410A 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB* Refrigerant GaSide Pipe Size O.D. 'CoolingOutdoor:95°F 35°C DB/75°F 24°C WB' Gas d Si 1/4" 3/8"/9.52 mm I (35° ) (24° ) Liquid Side 1 /6.35 mm 2 Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB* Max.Refrigerant Pipe Length 65'/19 m 2 Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB` Max.Refrigerant Pipe Height Difference 40'/12 m 'Heating at 17°F I Indoor:70°F(21°C)DB/60°F(16°C)WB" Connection Method Flared 'Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB` 'Rating Conditions per AHRI Standard • Maximum Capacity is at full speed and performance for INVERTER-driven System. Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: SLZ-KAl2NA Unit : inch (mm) • 1 M Fresh air I Detail drawing of fresh air intake intake y I $3-15/16($100) 125 N o �� / 3-X1/802.8) Cut out hole ) c \ 20-7/81530) / _ \Suspensiop bolt pitch/ Burring hole 1 U o �E� a= co r- <D N g - - ---------7f.------------ I 1 o , II, \ M 7 g /' i .\ M n o M . \ N ° I .- N N �� ) NM in .22-7/16570) \ v � p co / \ - A N 4 . 1 . 414 i � (71 M a,./ / TN. I coN M Ceiling surface N • \ !1 l-- ) v I c.s vo N• I7-27/32(199) r 7 N CO 13-27/32(352) N N 13-3/16(335) 19/32-1-15/32(15-37) 22-11/16-24-13/32(576-620) Ceiling hole 19/32-1-15/32(15-37) Drain pipe Wiring entry ccO"o 21/32(17) 7-15/16 202 9-1/16 230 VP-25 connection N Refrigerant (O.D.¢1-1/4032)) ,., pipe gas) I-- Suspension bolt M10 or W3/8 1111II m 1 Fi N L71 I r I r M ��i lei w — — M '— ✓ _i r_ a i = ur co 2 Terminal block Grille +� N m Ceiling surface N N N g0 co Q .N0 (Op in- c., W Cd - N N O.d + N -• 9 Models Refrigerent pipe Refrigerent pipe ,n 25-19/32(650) (liquid) (gas) 11-27/32(301) 1/4 inch 3/8 inch e? Air outlet hole Brand label SLZ-KAO9NA (0 6.35mm) (0 9.52mm) r ,../Grille flared connection flared connection L•I :VIM)-� ter' Drain hole 1/4 inch 3/8 inch M• 1 m C SLZ-KAl2NA (0 6.35mm) (¢9.52mm) N ;CaAuto vane flared connection flared connection — 1/4 inch 1/2 inch o R 0 SLZ-KA15NA (0 6.35mm) (0 12.7mm) to ',71-= o M t flared connection flared connection N N. N N MM —,__�,_,_,__._._._.__._._._.__._._._ M cn ci 0 N N C L6 •- O 7.- N Q Q :VIM) ro I _t —_---2(_.Air intake grille -Vane motor 14-27/32(377) , Air intake hole 1-3/8(35) , 2-5/32(55) Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: SUZ-KAl2NA < 15-3/4 > Drain hole q31-5/8 •71- Unit: inch c? ,7 Air in V RIR tom, K F Av 1 M co N Air in + Bi" A A 1-9/16 Air out 2-3/8 x 13/16 Oval hole 7/8>1 29/32 11-1/4 17/32 1 handle I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII0.1 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII co IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ^ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 'RI coN IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ,, n � I�1 Gas Liquid pipe :1/4:3/8(f(flared)lared)(KA09/12) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII -; �.I pipe VV V 1 - �� ,r,V •_=_ 1/2 (flared)(KA15) Mn 11-29/32 6-23/32 co 5-15/16 19-11/16 < > 31-1/2 2-23/32 < > < REQUIRED SPACE Basically open 4 inch or more without any obstruction in front and on both sides of the unit. 4 o'co 0,e ov,. 4/nor shore • F 4/ o ' (0 ph-,;"-, h. Open two sides of left,ft right, or rear side. MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com rut CEgRTIFIED,• c E 1 I us mss a°b"z, .TEo FORM#SLZ-KAl2NA-SUZ-KAl2NA-201604 —m.a,a.a,.m.n.u.,.— W. Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SUBMITTAL DATA: MSZ-EFI8NAB-U1 M-SERIES 18,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS M MITSUBISHI ELECTRIC Job Name: System Reference: Date: SPECIFICATIONS: Rated Capacity* Cooling*1 Btu/h/W 17,200 Heating at 47°F*2 Btu/h/W 21,600 Rating Conditions perAHRI Standard: Indoor Unit:MSZ-EF18NAB-U1 *1 Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB *2 Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:47°F(8°C)DB/43°F(6°C)WB For data on specific indoor units(all ducted,all non-ducted,and both ducted and non-ducted) combinations,see the MXZ Technical and Service Manual. Wireless Remote Controller ACCESSORIES: Electrical Power 208/230V, 1-Phase, 60 Hz Requirements Indoor Unit ❑ Condensate Pump(BlueDiamond X87-711/721;115/230V) Minimum Circuit A 1 o Condensate Pump(Sauermann SI30-115/230; 115/230V) Ampacity(MCA) o Anti-allergy Enzyme Filter(MAC-2320FT-E) o Drain Pan Level Sensor(DPLS2) Blower Motor(ECM) F.L.A. 0.67 Blower Motor Output W 30 Controls Moisture Removal pt./h 4.4 o Wireless Controller(MHK1) o Wired Remote Controller PAR-32MAA-J(Requires MAC-3331F-E) Field Drainpipe Size O.D. In.(mm) 5/8(15) o Wireless Interface for kumo cloudTM (PAC-WHSO1WF-E) o Thermostat Interface(PAC-US444CN-1) Airflow Rate(Lo-Med-Hi-Super Hi-Pow- DRY 205-240-279-328-388 Cooling WET CFM 176-206-240-282-334 Heating DRY 226-258-318-392-466 Sound Pressure Level(Lo-Med-Hi-Super Hi-Powerful) Cooling 30-33-36-40-43 dB(A) Heating 30-33-37-43-49 Unit Dimensions In.(mm) 11-3/4 x 34-13/16 x 7-11/16 (HxWxD) (298x884x195) Package Dimensions In.(mm) 14-1/4 x 38-3/4 x 10-3/4 (HxWxD) (362x984x273) Unit Weight Lbs.(kg) 26(11) Package Weight Lbs.(kg) 29(13) External Finish Munsell 3.7PB 2.0/0.1 Refrigerant Piping(Flared) Liquid(High Pressure) 1/4(6.35) In.(mm) Gas(Low Pressure) 1/2(12.7) Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: MSZ-EFI8NAB-U1 MSZ-EFI8NAB-U1 Unit: inch 7/1601 Oblong hole 1/16013/16 Oblong hole Installation plate 3-I/4 8-7/8 8-7/8V [<3-1/4 34-13/16 - � n n r-- , 34-7/16 3/16 _ 0. ..... mi 00 .crt Indoor unit/� ` Q� n �•� <7-1/16,_7-1/16 —\ 2-7/16> < 14-15/16 14-1/2 > <2-15/16 3/16 7-11/16 Air in Wall hole +3 4nJ Installation .late A Pi.in. y r — �y —. r �,I-1/8 Il , 2-3/16 3-11/16:,‘; Drain hose moo �� 4-5/16 ''' 2-5/16< 26-11/16 < 6-1/4 t j 2-3/8 1 l< J LII/16 `" - - a Air out 1 V - �2-13/16 3-3/8, n MSZ-EF15/18NA _s Insulation 41-7/16 0.D a Liquid line 01/4 - 19-11/16 (Flared connection 01/4) Gas line 03/8 - 16-15/16 (Flared connection 01/2) Drain hose Inslaiion 41-1/8 Connected part 45/8 0.D active length 15-3/8 Note: Extension pipe sire refer fo the specifications table. MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ETA us FORM#MSZ-EF18NAB-U1FOR MXZ-C MULTI-ZONE SYSTEMS-201607 Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MITSUBISHI ELECTRIC 1iii1ir.SLID® c . OLING & HEATING Split-ductless A/C and Heat Pumps SUBMITTAL DATA: MHK1 REMOTE CONTROLLER KIT FOR M-SERIES AND P-SERIES Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: MHK1 REMOTE CONTROLLER KIT INCLUDES: MRCH1 REMOTE CONTROLLER • Diagnostics: Displays and records error codes • For use with P-Series NHA4 • No addressing required systems,SEZ-4/SUZ one-to- .M'rs°e's"'E`EC''°" TM one systems,SLZ/SUZ • Can be integrated with other RedLINKTM devices one-to-one systems,MXZ-B 15 is.2 �� • Wiring:Connects using five-conductor cable from MIFH1 multi-zone systems,MSY/MSZ, IC too- i2° Wireless Receiver(cable included)to indoor unit;wireless RF and MFZ indoor units _ from the MIFH1 Wireless Receiver to the MRCH1 Remote • Backlit,easy-to-read display Mg "*° '"" @ Controller • Supports both Fahrenheit and • Dimensions:3-9/16"H x 5-13/16"W x 1-1/2"D(147 x 38 x Celsius D O O 91 mm) • User functions allow user to set: \. • Uses two"AA"alkaline batteries(included) -On/Off -Operation modes cool,heat,drying,fan -Set temperature(separate dual set points for heat and cool) MIFH1 WIRELESS RECEIVER - -Fan speed setting • Mounts next to or near indoor units -Airflow direction to allow MRCH1 Remote / • Day/Time display with a 12-hour clock • Filter sign display Controller operation of P-Series • Optimal start NHA4 systems,SEZ-4/SUZ one- • Adjustable auto deadband to one systems,SLZ/SUZ one to • Space temperature offset adjustment one systems,MXZ-B multi-zone • Display outside temperature and humidity(requires optional systems,MSY/MSZ,and MFZ indoor MOS1,sold separately) units • Hold function • Dimensions:6-7/16"H x 3-1/4"W x 1-5/16" \ • Temporary schedule override D(164 x 82.5 x 34 mm) \/ • Reset to factory default • Auto lock display MRC1 CABLE % ,l • Timer Operation: •Connects MIFH1 Wireless Receiver to five- -Daily Timer:On/Off times can be set up to 4 times per day in pin CN105 on indoor unit control board 15-minute increments. -Weekly Timer:On/Off times can be set up to 4 times per day of •Five-conductor wire with preterminated ends the week in 15-minute increments.Choice of 5-2 and 5-1-1 •Length:6-1/2'(2 m) weekly schedules for heat,cool,auto(separate for each mode) -Auto-off Timer:Turns indoor unit Off at scheduled time up to OPTIONAL ACCESSORIES 24 hours in advance • Room Temperature:Displays room temperature sensed either at ❑ Portable Central Controller(MCCH1;for use with Wireless Remote the indoor unit or at the remote controller(default) Controller Kit MHK1)* • Set temperature range limitsdependent on the system connected): n Outdoor Air Sensor(MOS1;for use with Wireless Remote Cooling from 50°to 99°F Controller Kit MHK1)* Heating from 40°to 90°F Auto from 50°to 90°F with dual temperature setting *See Submittal for information on each option. MIFH1 Wireless receiver r1 v-_Yc; MRCH1 MOS1 Remote controller / r— Outside / Air Sensor (Optional) ' �i , MCCH1 —.._- Portable �2, , central controller,..._) 1 0 Mr.Slim Outdoor Unit MITSUBISHI 3400 Lawrenceville Suwanee Rd p Q FORM#MHK1- 201108 ELECTRIC Suwanee,GA Tele:678-376-2900 4 Fax:800-889-9904 ENERGY STAR RedLINK is a trademark of Honeywell,Inc. Toll Free:800-433-4822(#3) PARTNER ©2011 MITSUBISHI ELECTRIC&ELECTRONICS,INC. COOLING & HEATING www.mehvac.com Live Better Specifications are subject to change without notice.