HomeMy WebLinkAboutDRB16-0505_M-0_1478905883.pdf tiofz041 ....zApitir. le, TolinMechani :_ j4111 :i MECHANICAL GENERAL NOTES SYMBOL LEGEND SYMBOL LEGEND ABBREVIATIONS Building Efficiency and Sustaini.% ARCO 10 FDFLOOR DRAIN ABV ABOVE INV INVERT ELEVATION 1 . ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITIONS OF THE RULES, REGULATIONS � MATCHING LINE ® AND CODES OF THE STATE OF COLORADO AND THE LOCAL JURISDICTIONAL AUTHORITY. ACU AIR CONDITIONING UNIT KW KILOWATT A Service Logic CohriI,dny r 18x12 2. THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL WORK UNDER HIS/HER CONTRACT WITH ALL © SECTION DESIGNATION 1(1) SECTION NUMBER DUCT SIZE (CLEAR INSIDE DIMENSION) AD ACCESS DOOR KWH KILOWATT HOUR OTHER BUILDING TRADES. ® DRAWING NUMBER I FIRST FIGURE INDICATES PLAN SIZE AFF ABOVE FINISHED FLOOR LAT LEAVING AIR TEMP. 18x12 } 3. ALL EQUIPMENT & DUCTWORK TO BE HELD HIGH AS POSSIBLE NEAR STRUCTURE UNLESS NOTED OTHERWISE. Ik I AL ACOUSTICAL LINING LBS POUNDS DETAIL DESIGNATION DETAIL NUMBER 18i) ALT ALTITUDE LD LINEAR DIFFUSER 4. THIS CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS PRIOR TO THE PURCHASE, FABRICATION AND ® DRAWING NUMBER S S INSTALLATION OF ANY EQUIPMENT, DUCTWORK, PIPING, ETC., AND SHALL INFORM THE ARCHITECT OR GENERAL APPROX APPROXIMATE LPR LOW PRESSURE STEAM CONTRACTOR OF ANY DISCREPANCIES FOR RESOLUTION. ® EQUIPMENT EQUIPMENT TYPE i 180 i ROUND DUCT DIAMETER SIZE RETURN DESIGNATION EQUIPMENT NUMBER ARCH ARCHITECTURAL ®® 5. CONTRACTOR SHALL PROVIDE OWNER WITH COPIES OF OPERATIONS AND MAINTENANCE MANUALS FOR ALL TYPE (SEE SCHED) NEW WORK AVG AVERAGE LPS LOW PRESSURE STEAM ®® �� INSTALLED EQUIPMENT. SUPPLY, 12x12 WGS-1, 12x12--SIZE 18x12 AIR OUTLET/INLET �_ - BF BELOW FLOOR --__---__--__-_-- 6. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT SHOW EVERY DUCTWORK OFFSET REQUIRED. (550) DEVICE DESIGNATION (550)�� r -S ACOUSTIC LINING IN DUCT BG BELOW GRADE LVR LOUVER mAz THIS CONTRACTOR SHALL COORDINATE WITH THE EXISTING, AND OR NEW, STRUCTURE, ELECTRICAL, CFM 18x124Erri (SIZE NOTED INDICATES INSIDE DIMENSIONS) - - - _ MECHANICAL, PLUMBING, FIRE PROTECTION AND CEILING TO PROVIDE OFFSETS AS REQUIRED AND BHP BRAKE HORSEPOWER LWT LEAVING WATER TEMP. --- APPROPRIATE. 0 PROJECT NORTH ARROW MAT MIXED AIR TEMPERATURE 1600 Stout Street, Suite 450 18x12 BO BLANK OFF CO 80202 7. ALL RECTANGULAR AND ROUND DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL IN S r S DOUBLE WALL DUCT BOD BOTTOM OF DUCT MAX MAXIMUM TEL Denver,720.644.5044 ACCORDANCE WITH SMACNA HVAC DUCT STANDARDS. DUCTS TO BE SEALED PER SMACNA PRESSURE CLASS 0 ELBOW TURNED UP (SIZE NOTED INDICATES INSIDE DIMENSIONS) 18x12 REQUIREMENTS. BOP BOTTOM OF PIPE MBD MANUAL BALANCING www.mazzetti.com C'S ELBOW TURNED DOWN BTU BRITISH THERMAL UNIT DAMPER 8. ALL NEW RECTANGULAR DUCTWORK SHALL HAVE DUCT LINER IN COMPLIANCE WITH NFPA 90A AND AS S 0 S BOTTOM PIPE CONNECTION Project Number: 164-041 DEFINED IN KEYNOTES. SHEET METAL SIZE SHALL BE INCREASED TO ACCOMMODATE THICKNESS OF LINER. `��IIIIII�S BTUH BTU PER HOUR MBH THOUSAND BTU/HOUR DUCT SIZE INDICATED ON DRAWINGS IS THE INSIDE CLEAR DIMENSION. I TOP PIPE CONNECTIONIII FLEXIBLE CONNECTION IN DUCT CC COOLING COIL MFG MANUFACTURER S C C S SLOPED CHANGED IN PIPE ELEVATION MIN MINIMUM 9. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SPATIAL REQUIREMENTS, ACOUSTICAL, THERMAL, AND CD CEILING DIFFUSER ELECTRICAL PERFORMANCE CHARACTERISTICS AND COORDINATION OF ALL INSTALLATION REQUIREMENTS FOR S S PITCH PIPE DOWN IN DIRECTION OF FLOW NWMI1NV FLEXIBLE DUCT CE CEILING EXHAUST (N) NEW EQUIPMENT SUBSTITUTIONS FROM THAT DEFINED AS THE BASIS FOR DESIGN. REVIEW AND APPROVAL BY THE DESIGN TEAM DOES NOT ALTER OR MITIGATE THIS RESPONSIBILITY. S ® PUMP S I' S CFF CAP FOR FUTURE N/A NOT APPLICABLE 5 5 PIPING FLEXIBLE CONNECTION - = 10. CONTRACTOR SHALL VISIT THE PROJECT SITE TO BECOME ACQUAINTED WITH EXISTING CONDITIONS. FAILURE VOLUME DAMPER IN DUCT CFH CUBIC FEET PER HOUR NC NORMALLY CLOSED _-;Q.........REG�s7 ,, TO DO SO SHALL NOT RELIEVE CONTRACTOR FROM THE RESPONSIBILITY FOR PERFORMING THE WORK S DQ ; GATE VALVE + + . \,\? M. 67/07%`' �' CFM CUBIC FEET PER MINUTE NIC NOT IN CONTRACT =o :