HomeMy WebLinkAboutDRB16-0505_M-1_1478905885.pdf tiofzo4 ....zApoiToIinMechanijJBuilding Efficiency and Sustain �3 :quo i 1(E) NATURAL GAS METER GENERAL NOTES A Service Logic Carriodny (N)24x22 GOOSENECK WITH BIRD SCREEN 1. FIELD VERIFY ALL EXISTING CONDITIONS NOTED ON El PLANS PRIOR TO COMMENCING ANY WORK. FILTER SECTION (N)36x30 WITH HOOD AND BIRD SCREEN 2. ALL RECTANGULAR ELBOWS SHALL BE INSTALLED WITH 1 TURNING VANES. / 1 .1 A PA 5HIGH ROOF - 12 -0 3. PROVIDE 12"x12" DUCT ACCESS PANELS ON BOTH / �� UPSTREAM AND DOWNSTREAM SIDES OF THE UNIT, PROPERLY SEALED TO AVOID AIR LEAKAGE. ® (N)MOTORIZED o Ei (N)24x24 EA 4. INSTALL FURNACE PER MANUFACTURER'S / ®®®® BY-PASS DAMPER •= rJ p III '- ■ , I- RECOMMENDATIONS AND ENSURE ALL CLEARANCES ARE / �® (N)OSA PLENUM DF / S PARAPET - 3 -0 MET. mAz En.I 1 v I LOW ROOF - O'-O" 5. PROVIDE SLOPED ROOF ON HORIZONTAL DUCTWORK TO / PREVENT SNOW LOADING.If' / 1600 Stout Street, Suite 450 II 6. PROVIDE OUTDOOR AIR TEMPERATURE SENSOR AND Denver, CO 80202 OSA DN TO EXHAUST UP OPERATE FURNACE CONTINUOUSLY BASED ON OUTDOOR / TEL: 720.644.5044 AIR TEMPERATURE. FURNACE SHALL BE ENERGIZED MECH ROOM FROM MECH ROOM AND PROVIDE HEATING SO LONG AS THE OUTDOOR AIR / www.mazzetti.com TEMPERATURE IS 55 DEGREES F (ADJ) OR BELOW. Project Number: 164-041 PROVIDE A SUPPLY DUCT MOUNTED TEMPERATURE / SENSOR TO MAINTAIN DESIRED DISCHARGE AIR TEMPERATURE (ADJ.). / (E) MAIN LOCATED INSIDE GARAGE 7. THE MOTORIZED BY-PASS DAMPER SHALL BE OPEN WHEN THE OUTSIDE AIR TEMPERATURE IS 55 DEGREES F (ADJ) OR HIGHER, AND CLOSED WHEN THE OUTSIDE AIR TEMPERATURE IS 54 DEGREES F (ADJ) OR BELOW. / = ,.�P�p REG�s� OMECHANICALSECTION /SCALE: 1/8" = 1'-O" KEYED NOTES s/�:• � JJZ" : 1. PROVIDE NEW OUTDOOR DUCT FURNACE, DF-1. . � - INSTALL ON TEEL S ON WALL. COMBUSTIIONSAIR INTAKE OIST7' HIGHO" ABOVE ROOF.NSURE / I'Fss�ONAL c-- CONNECT DF-1 TO LOCAL 120V POWER CIRCUIT, RE-WIRE AS REQUIRED. I 10/26/2016 2. PROVIDE FILTER SECTION WITH 2" PLEATED FILTERS IN / THE VERTICAL SECTION OF THE INTAKE DUCTWORK. MANUAL FROM 3. DEMOLISH AND CAP EXISTING UNDERSIDE CONNECTION / MAIN PL MAIN.SEE 24"x24" EXHAUST DUCT TO THE GARAGE IN SHUT-OFF PLAN FOR VALVE \ SIZE. MECHANICAL ROOM. ABANDON EXISTING DUCTWORK / -\i AND FLOOR REGISTER IN GARAGE. CONNECT NEW 24"x24" EXHAUST DUCT ON TOP OF EXISTING RETURN / GAS APPLIANCE 1111 S el - DUCTWORK IN MECHANICAL ROOM AND UP THROUGH - 1ROOF. RELOCATE EXISTING MOTORIZED EXHAUST AIR / �- - DAMPER TO NEW EXHAUST DUCT OR PROVIDE NEW IF -E B INACCESSIBLE. / CONNECT TO EXISTING GAS PIPE i i11 LOCATED IN GARAGE. CONNECT ------ / DOWNSTREAM OF EXISTING (II) III BRANCHES AND REGULATE ' i- �- _ DOWN TO 14"WC. GROUND ATTT) _ -7 JOINT UNION FLEXIBLE GAS i= / (N)1" NG CONNECTOR. ce 18" MAX. > `� c° REVISIONS ,I„` / NO. DATE DESCRIPTION DRIP LEGY - 09/14/2016 PERMIT SET SAME SIZE AS DROP 1 10/26/2016 REVISIONS 22 � 24x TERMINATEOSA WITH O DF GOOSENECK AND BIRDSCREE A ( !P1 UM v DN TO MECH RO'-► 111111111, © GAS LINE CONNECTION DETAIL DEMOLISH (E) OS' 1 e i a—Q_ Vii M-1 SCALE: NOT TO SCALE A� © 12x12 ACCESS PANEL �� Q I " (N)24x24 EA O UP FROM MECH ROOM lippllppr.00000111!4iiii (N)36x3I ARCHITECTS PROJECT# GAS FIRED OUTDOOR DUCT FURNACE WITH HOOD AND BIRDSCREEN 0, #'FURNACE DESIGN BASIS/ CLIENT PROJECT# SYMBOL SYSTEM INPUT CAPACITY OUTPUT CAPACITY EAT TYPE MIN. HEATING TSP WEIGHT REMARKS CLIENT ACCOUNT# SERVED MBH MBH F DEG. CFM INCHES LBS N DF-1 OUTSIDE AIR 125.0 68.0 -16 INDIRECT 900 0.1 137 HEATCO HDD125-W, 115VAC PROJECT TITLE SIMBA RUN 0 NOTES: 1. PROVIDE FURNANCE CONSTRUCTION FOR INSTALLTION OUTDOORS AND ON THE NEGATIVE SIDE OF SYSTEM FAN. VAIL CONDOMINIUMS 2. ENSURE AT LEAST OUTPUT CAPACITY LISTED AT PROJECT SITE ELEVATION (8,000 ASL). \ \#4 DUCTWORK RE-MODEL m 3. PROVIDE FAN RELAY TO ALLOW FURANCE TO OPERATE 60 SECONDS BEFORE FAN OPERATION. 4. PROVIDE ELECTRONIC MODULATING CONTROL. 5. PROVIDE HIGH TEMPERATURE RISE OPTION. SHEET TITLE MECHANICAL U m o, SITE AND ROOF PLAN 0 > SCALE DATE 2 15 NOTED 7-19-2016 EQUIPMENT SCHEDULE (T) MECHANICAL SITE AND ROOF PLAN - NEW WORK ItSHEET N0. SCALE: NOT TO SCALE M-1SCALE: 1/16" = 1 -0 a M - 1 c C7