Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB16-0540_Gate Information_1481659320.pdf
TM 12 4.1.0 Strong rm . QUICK START STEPS __ , < Top cover 71\ N Attachment Plate / changes depending LEFT HANDING (L) on arm material Standard. '� Drive Belt / cover rEnd cap Factory ships left handing operator. A .1� NOTE:If your site requires - . right handing,place the order with �ioir ' '_� qj your distributor as a StrongArmPark w moo;_ � i �__r �-. I ,00 Knob DC with"right handing." _- u'„ 0� Q NI \% T � ' . Handing changes can be completed 'w, ®® ® r in the field,but it requires additional 0 time and effort.See page 3. o / Barrier Arm �1 IL HyProtectTM `/ o Breakaway/ Breakaway �i fasteners Arm Mount Batteries Dil'"II,_ Torque to 15 in-lb. Each bolt is secured with an aluminum lock ° washer and nylon hex nut.Torque to 15 in-lb. i� ° See page 4. li Arm Length Fasteners Applies to: m) 2 nylon bolts Low wind <10 ft 1 nylon bolt High wind Keyed y 9 �_ latch >/=10 ft 1 steelanboltLow wind FSpring >10 ft 2 steel bolts* High wind assembly (StrongArmPark DC 14) *NOTE:Be aware,when using two steel bolts, i that the arm may bend before the nylon nuts } ji fail which voids the Warranty. 0 Smart DC Controller 0 o D /c Front access panel ° ��o Chassis Tensioning nuts UNPACK THE OPERATOR r ecurl Simple. Reliable. Secure.® 1 SITE PLANNING & OPERATOR INSTALLATION • Arm Length A O® - C/L-Ai— Arm length is measured 0 Tools Needed: from edge of operator. ,i CO Standard hex key set StrongArmPark DC 10: 41 in Standard socket set Up to 10 ft(3 m) (104 cm) StrongArmPark DC 14: Crescent wrench 10 to 14 ft(3 to 4.3 m) 35 in Wire stripper with spring assist. (89 cm) NOTE:Articulating arm Concrete drill options shown below are available.Contact HySecurity Sales. j . e 0 Articulating Arm Option: Clearance Requirements :�(298cm) 'x(38 cm) —40: — • L5'h inch (14 cm) — 7 ft Option: 43 4 7 ft(228 cm)vehicular OPEN clearance IMPORTANT:When installing the operator be sure to comply with all local [8 ft barrier arm length,CLOSE] government regulations and codes and read the Important Safety Instructions found in the manual. 8 ft Option: 8 ft(244 cm)OPEN clearance — [10 ft barrier arm length,CLOSE] 9 ft Option: Earth 2 in(5 cm)minimum — 9 ft(274 cm)OPEN clearance ground conduit height 1_ [11 ft barrier arm length,CLOSE I I\ \ \1 Ik. t . Grade level '/ I-- N.-- �'r--- High voltage wires / Base chassis f � i��Low voltage/ Communication wires IConsult • . V local codes z \—Vehicle Loop NOTE:To reduce electrical It • • d for proper control wires interference,run high ` —Grade depth voltage and low voltage Concrete pad through separate conduits. Extra conduit(Dual or DANGER Turn OFF AC power at the source Sequenced Gate wires) 19 in • (circuit breaker panel)before 'E (48 cm) installing the operator. Follow facility Lock Out/ A Tag nd Out procedures. sMake n sureebothlthe DRoute 6 AWG round and AC power switches on the Control Box are g in the OFF position. - 11111111mi r wire (maximum length a tun 3 ft, 91 cm) through19 in I The potential for lightning discharge exists with all 1(48 cm) • DANGER gates,fences and gate operators.National Electric conduit & attach Code(NEC)requires a separate earth ground in addition to the to ground lug.—/1 required equipment ground.A local earth ground also serves to protect the electronic controls. Page 2 .'i HySecurity MX3651-01 Rev.B StrongArmPark DC Quick Start Steps www.hysecurity.com ©2016 2 REVIEW HANDING AND INSTALL THE CHASSIS LEFT HANDING (L) Standard, Factory Default RIGHT HANDING (R) _ Emmi mm ii___-----__--,111111111h1111P LI" E1lim To take full advantage Changes to operator handing in the �, ront access panel of the break away field,must also be addressed in the feature,the front Installer Menu. access panel must Smart DCS face oncoming traffic. SH R(RIGHT) I Controllerji'II GATE HANDING OPEN CLOSE STOP MENU RESET Mil 0 0 O 0 0 PREY NEXT SELECT BARRIER ARM SIDE I , - _r REMOVE 1 X12 in i ; TO ,3e-ern 1- .I TOP COVER o �� ATTACH DRIVE 55BELT COVER 71, in CONDUIT n (1' cm) CUT-OUT Z1 /�:� 0 Warning Label ' o0' 2 Place on front access --,14- --70,7-1":. ACAUTION Be sure to 0 panel facing incoming"ri =�; % secure the 5/8 inch slots(16 mm) traffic. 3-a % belt cover with the ,6 Use 1/2 x 3Ys inch fasteners provided.If the concrete anchors 40Required for UL 325 belt cover is not installed, compliance. a potential risk of injury _ J — ' — l _ n exists. ,itStrongArmParkB"Mounting Template `� ° Warning Label CUT OUT MOUNTING TEMPLATE v,, ,;6� Plcoe on side panel facing Anchor bolt, incoming traffic. Cut out the base template on the washer, Required for UL 325 shipping box and use it to mark the °• ,,.= (4d nut t compliance. mounting locations on the concrete pad. % 0, ` Concrete pad ! p), INSTALL THE CHASSIS Earth ground "°j• jGrade level Remove front access panel. k� ° {,,,, ° 41111 To easily access and wrench-tighten the anchor bolts, swing the base panel open (or iconduit remove it). to CZD NOTE: The spring tension on StrongArmPark DC14, should be adjusted BEFORE fastening the operator Grounding to the concrete pad. The proximity of the conduit to rod depth per Foo the adjustment nut at the base of the spring makes it difficult to wrench-tighten. www.hysecurity.com ©2016 StrongArmPark DC Quick Start Steps MX3651-01 Rev.B at HySecurity Page 3 3 INSTALL THE BARRIER ARM REMOVE CAP SCREW, LOOSEN SET SCREWS Loosen screws(4x) Remove buttonhead and remove Top cap screw and fender 1. Use a 7/32 inch hex key to remove the button Cover. washer. airi /I HyProtectTM head cap screw and fender washer. 1, breakaway arm 2. Loosen the set screws in the breakaway arm Loosen set mount 1 screws. mount using a 5/32-inch hex key. Ill O Do NOT 3. Loosen 4 cap screws and remove the top cover. remove. ®� (S\. %ii, W Fasteners(6)secure Button cap bolt and / arm bracket to fender washer inside �� breakaway arm mount breakaway arm mount .t, End cap `s � `+ p j l�i� \ ' m �i ,......, 0 It '\ � ' '... ' Warning Labels > ��61.E _.., i °���, UL 325 compliance 1 \i \i , requires placement \ 1.� on both sides of I barrier arm. '� O .0 ( �- HyProtectT"^ �� breakaway arm �� mount Knob Attachment plate INSTALL THE HYPROTECTTMIli Specific to arm material secures BREAKAWAY ARM MOUNT cover to arm LEFT HAND OPERATOR (SHOWN) NOTICE:See chart on the Standard shipment is L (left handing) cover page for fastener selections.Ifpossible,remove NOTE: For articulating arm assembly,see the instructions 11 ' that accompany the arm package. the barrier arm when high wind warnings are in effect. '. 1. Hold the HyProtect breakaway arm mount so it o '•c'- is parallel to the physical stop lever, oriented to -o- �_ 4J operator handing. `� � ` ` 2. Align the splines and slide the arm mount so it ,,_ t�. �� �,,,,J�� ' `.'• � 11 4� contacts the physical stop lever. \ a 3 \N ..,p -, 3. Open the arm mount. Physical stops ' 1 ° (bumpers) , 4. Place the n the � Physical stop lever(L) /JINN , buttonhead caper screw. r . Apply Loctite gra _ �� � and tighten 4i �''�,� % i set screws. ' —--—-Or?"-..7 il , . iSC°71 ' 011111 , . } c3 _4- 1 _ ‘e,T,--„,:, - . 1 . -.., i-fli - 0 0 .1 0 . idelt 0 ,,, z,;, T) -. Iv 0 ' d ,-,N, ...4 91 o 1IP1 6. Close HyProtectTM mount and insert two fasteners. To 5. Apply Loctite®242 blue to threads of buttonhead determine which fasteners to use, refer to the chart on the cap screw and the 2 set screws. Securely tighten all cover page. Secure using the supplied washers and nuts. 3 fasteners. 7. Continue arm assembly. Page 4 1r HySecurity MX3651-01 Rev.B StrongArmPark DC Quick Start Steps www.hysecurity.com ©2016 4 VERIFY POWER IS OFF, AND THEN CONNECT AC WIRES TURN POWER OFF DANGER Turn OFF AC power at the source Control Box (circuit breaker panel)before accessing the wires in the junction box. Follow facility Lock Out/Tag out procedures.Make sure a a e A both the DC and AC power switches are in the OFF position. DC power switch «. " i� g disconnects motor i hi IPI VII I1I1I PPand battery. C�.;T (0717-''''-111 p `� �� if I "-ter CONNECT �o I� _ O RED Place the power switches ®OFFF--I`�,_ '� BATTERY in the OFF position. 0 o WIRE 0_ AC power switch ill- 3 disconnects _ incoming AC power ® / ! � rE3 0 to the operator. ® t P ja.. Lill 0 A DO NOT connect the _ I 115VAC service outlet to Toggle switch: 208 or 230VAC power supply wires!To use QIP gg ,c the 115VAC service outlet on a 208 or ry Hold OPEN locks al a a a o 230VAC installation,the electrician needs barrier arm in the to run an extra neutral wire to the operator open position. (‘L:--) _ 0 from the power source and wire the service outlet per code. AUTO Normal Operation. Pi Service Outlet Hold CLOSE ignores\--�r1 0 115VAC only all commands and _ I�'T1_ '� inputs.Secures 115VAC wires for the barrier arm in a High Voltage Service Outlet closed position. Cover �`'I�I--. (junction box) ® ® Voltage selector ���j A�((�� I� 14 �� and label �r- switch is factory t� �����,� \I� set to 115V. _ --441e--, �- NOTE:If / 1 �� -��_ , (--,u4 :park 115 10Si_ _./A �., r = S SE ONLY COPPER power input is i� ® �I rows �1�) > ONDUCTURSWITH208/230V,move �1�=^�. ®FF, 1, i TEMPERATURE RATING 110111/C ,�I/ , PFli OFATLEAST75°C���iG `� the switch so �r i ^,N ,,��1„,,,,, FACTORY CONFIGURED 230V appears ® I liu ` , ,jl`�I I _= 5 CONNECT ACCESSORIES All accessories require a minimum of two connections on the Smart DC Controller: • A device input • A Common Bus Terminal (COM) NOTE:Other devices may require more connections or configurations. For example,the Fire Department(EM ERG OPEN) input requires a +24 volt input.The connection must be activated by changing the setting through the Installer Menu. UL 325-2016 updates describing installation of external entrapment protection sensors can be found the Programming& Operations Manual. NOTE:Smart DC Controller, Rev F shown without the 24VAC. -4124VDCh ' 24VDC� I; � �- 1111 Lr�24VA �� /— /� �� Two power SII � ` `- �, .24VA' '�i l� supplies(2 it \. \e. VI J I I ,I,I I terminals each) lsl,l .IJ I0 are available j,zvoc� ,I,IJ J.I.I tl<I,I for peripheral • ,zvoc� I N_ connections: p .��; �/• 24VDC&12VDC �� o�� . O;l��4cit i —24 D 7i4sNOTE:Each power COM �jr )II c� O�� 4111rfA supply(and its •MIT�z4 Dc� �� ��corresponding ' I; ��� 'terminals)can be used in any COM I kl combination to COMMON � i, HY-SA draw the available TERMINALS COM �( i ,2voc —FREE FREE EXIT lir_ 1A maximum. COM \j��r,2voc41 � • ■ �ll Multi-colored LED Access controls • , indicates power and gate (Ex.Card reader,keypad) I r ., status. HY-5A HY-5A — •, IIIA RS-232 INSIDE LOOPiGil i Q Ethernet (Inner Arming . ••. Ili �• expansion u 3 � Loop) O 1 to , ] Parking Site Use EYE c iu HY-SA , TRANSIENT OPE\I 41.�' OUTSIDE LOOP The label for the USER EYE II( � ' t ' (Outer Arming Smart DC Controller Exrr h.. .i Red LED 1; Loop) accommodates CLOSE LOOP 1 y�y heart I�� armingloops and BLOCK _ �� I� EJ(Ir 1 �� beat -. re �. establishes which SPECIAL i�� r IN OBS —•• indicates open commands USER ED IN OP I��I 1---indicates need to be wired • •' —' working. USER RELAY I fil5 HY-SA for vehicle counts TENANT k�1 I, Iromechanial CENTER LOOP (transient,special, USER I• �'oop j.,1 'OD +, VEHICLE LOOP and tenant"user EDGE I I C Press button to light types"). SPARE active inputs. The software SENSOR 3 �� 'r identifies the access 24v 11,3/3 a ,� . w„ ��, �`ti` EMERG --''iyj 1� 1 control inputs and •.; Ii OM NeEXIT Ni _i___--1, the arming LOOP r c•M=s n corpoP•I • EDGE loops to control LEDsSB PORT Rsas5s relay and network outputs. BLOCK / USER RELAY 2 COMMUNICATION EXIT Solid state Preferred wire lead connections for the Radio receiver arm lights. INNER �e,.. / Connection for Dual(Primary/Secondary or Sally Port) ARMING or Sequenced gate systems. OUTER ARMING NOTE:The most current software must be La I---- on your Smart DC Controller. Page 6 .`i HySecurityMX3651-01 Rev.B StrongArmPark DC Quick Start Steps www.hysecurity.com ©2016 6 TURN ON POWER, LEVEL ARM & CONNECT LIGHTS When both DC &AC power switches are in the OFF position and you turn them ON, the operator initiates a target search and the barrier arm travels open. No physical limit switches exist. The open and close limits are established by sensing the arm position. Even if AC power is lost and the batteries are fully drained, the limits remain intact. The only exception occurs when factory defaults are reinstated or the Smart DC Controller is replaced. For more information, refer to the StrongArmPark DC Programming and Operations Manual. Physical stops (bumpers) LEVEL THE ARM & ADJUST PHYSICAL STOPS Or' The limits are factory set at 90° and, if adjustments are needed, level the I o � - arm using the following procedures: ,vofi, ,, _ 1 li riliiiir; v F,:• Access the Installer Menu to re-establish o '� 1 Learn Limit (LL) mode iI viii, Physical stop • Adjust the physical stops (bupers) o teJ- levers To level the arm or change the gree of angle, bumpers can be adjusted up or down using a 1/4" hex key and 3/4" open end w nch. At full Open or Close, the physical stop lever should lightly contact its physical stop (bumpe ). To make adjustments to the ar position, the operator needs to be in Learn Limits mode. Setting the Spring on the StrongArmPark DC 14 LEARN LIMITS MODE HYSECDRITY I Establish limit settings. GATE CLOSED 6.111- lik 1. Start at a gate status display. 2. Press MENU,twice. 1 i p O O O O ,,,, V NEXT SELECT 3. At the CLOSE TIMER display, I simultaneously press and release OPEN CLOSE STOP MENU RESET CT 0 (OFF) I the OPEN and RESET buttons. CLOSE TIMER 4. At the LL 0 display, press SELECT .4T CLOSE STOP �- LI. and change the display to 1 using it 0 0 i0 I • I Arm Length Spring Setting (H) o o the NEXT button. Press SELECT NEXT SELF 10-12 ft(3.6 m) 3.5 inches(89 mm) r'8 again and the LEARN OPEN display appears. LL 1 (ON) I 12- 13 ft(4 m) 3 inches(76 mm) LEARN LIMIT - 5. Hold the OPEN button until the 13-14 ft(4.3 m) 2.5 inches(63 mm) _ arm reaches the desired open OPEN CLOSE STOP MENU RESET NOTE: If the arm length is less than limit. Release the OPEN button. PROEV NEXT SEDT O O 10 ft(3.3 m),disconnect the spring from NOTE:Too far open or close? I the physical stop lever. / k-,8 Press the opposing function • button to reverse direction. II ' LL 6. To preserve the limit setting, —I = •• LOSE STOP MENU RE Hi i press STOP twice. LEARN CLOSE I • I iia O CII • I Spring is pre-tensioned _ _ ___,3,1 appears on the display. T SELECT for a 10 to 12 ft barrier 7. Hold the CLOSE button until the arm (3.6 m). Adjust spring arm travels to full close. Release RN OSE I tension by turning the ® o o the CLOSE button. adjusting nut. 8. To preserve, press STOP twice. CLOSE STOP 0 0 0 0 0 NOTE:If you need to change a StrongArmPark DC 14 handing in the field,it 9. Cycle the operator(Open/Close) requires moving the spring's eyebolt to the opposite physical stop lever.Refer several times. to StrongArmPark DC Programming and Operations Manual. 10. If needed, adjust the bumpers so they contact the levers. www.hysecurity.com ©2016 StrongArmPark DC Quick Start Steps MX3651-01 Rev.B .:i HySecurity Page 7 7 CONNECT ARM LIGHTS TO SMART DC CONTROLLER Connect to 24VDC WIRING THE LIGHTS &COM ow g i�o No ,- 1. Make sure both AC and DC power switches are turned OFF. �® ��i i.i i.i ��'.i,i .i.i.i i� o 2. Insert leads of wire harness through the hole in chassis. Feed the cable through Ng the interior of the chassis, as shown. Pull enough cable to reach the Smart DC 4k- g ` 1�5;:.� Controller terminals. E-,-'• o0C xt���_ COM I� 4`•_ a OO® f�!14 1` NOTE:Connect wire lead to 24VDC! Lights are dim when connected to 12VDC. coM I;' ;. ® 2 . .....Feed cable through the Chassis COM i, 3,. '. �� COM 111-7"2-0,c O u� 1 ! CO.I I L"J.' o ',Ui `.�, iu CO.I �A111 o .See CAUTION ♦\ STOP I i'`+ _i _ Wiwi—ear�_. i \/ \ ® \ '° Ali-% OPEN, o in .11 � ` • aOEI�'�: M. 0 O la ISI QDSE yCE 1 i b Ber r”C 0 a lia Ir■ off. SII, o , �1 Ia _.� � 5 1 Im7M ,•�Black wire—%' ®� _ a___'� Nob.l G'a :-Till COM 8 A COM OPE 1<V EOGE EOM NSI LED light connector Wire harness Secure cable with strain relief bushing. $�— °""A� connector USERREIAY2 NOTICE:Allow for arm travel. Preferred wire lead sora,e Cable loop length:8-inches(20 cm)min. connections for the 3. Attach the end of the wire harness(on outside of chassis)to the LED light arm lights. connector on the arm.The wire harness connector is keyed. Be sure to properly seat the connectors before threading close. Connect Wire Leads 4. Secure the harness to the chassis with the strain relief bushing. 5. Connect the one wire lead to the 24VDC power supply terminal. 6. Connect the other wire lead to the NO terminal on User 2 Relay. 7. Turn on both AC and DC power switches.Arm will cycle to search for the target R22 28 FLASH AC home position. RELAY 2 LOGIC 8. When the arm has stopped moving,access the Installer Menu. 9. Set User Relay 2 logic function to one of the following: • R2 "27": LED lights remain on throughout arm travel and turn off when open OPEN CLOSE STOP MENU RESET limit is reached. • R2 "28": LED lights flash throughout arm travel and turn off when open limit is 13 0._S/_ 0 0 reached. PREV NEXT SELECT NOTE: Both selections will turn off the lights,which preserves battery life, in the event of AC power loss. Configure the Installer Menu: Relay 2 Logic ACAUTION If User Relay 2 is being used for accessory devices,you can connect the LED lighting wires directly to 24VDC and COM.Take note that this type of connection does not turn off the arm lights in the event of AC power loss and will drain the batteries quickly. COMPLETE THE INSTALL HySecurity Tech Support • Refer to the installation manual to configure User and Installer Menu options such as gate speed, 800-321-9947 Close Timer, relay functionality,etc. • When the operator is functioning properly, replace the operator's covers and secure the key latch. • Review the Important Safety Instructions and the proper use of the barrier arm with the end user. • Position WARNING labels per UL 325.Take photos of the barrier arm installation site. Page 8 :V HySecurity- MX3651-01 Rev.B StrongArmPark DC Quick Start Steps www.hysecurity.com ©2016