HomeMy WebLinkAboutDRB17-0007_Plaza Lodge - Project Information_1492711229.pdf Property Information " OF P4
Property Address 291 BRIDGE STREET, UNIT R-1 VAIL, CO 81657
ri 1,1
Parcel# 2101-082-62-007 .4
Legal Description DESC: HOUSEHOLD FURNISHINGS Subdivision: PLAZA LODGE Un # r,`,
ir
,WIL ti
Development Site Area sq ft 10,460 acres .24 buildable sq ft #
hin DR=
Zone District/SDD# Commercial Core 1 CC1 APPROVED
) 4/19/2017
Hazard Zones Snow Avalanche r High Severity Moderate Severity TN/A 12:00:00 AM
Sections 12-21 & 14-7 Debris Flow r High Flow r Moderate Flow r High Avalanche r N/A
Rock fall T High Severity r Medium Severity TN/A
Excessive Slopes r>_30% F N/A
Floodplain 100 year floodplain r Floodway r Wetlands V/A
Creeks, Streams ['Gore Creek r on site r adjacent to site F N/A
Section 12-14-17 ❑Other tributary: Fon site radjacent to site ' N/A
Project Information
Project Description
Development Standards Allowed Existing Proposed
Gross Residential Floor Area Primary sq ft 3705 3205 3705
(maximum)
Chapter 12 15 Secondary sq ft
EHU sq ft
TOTAL sq ft 3705 3205 3705
250 Addition Interior Conversion
Credits:
Setbacks(minimum) Front ft N/A N/A N/A
Section 14-10-4
Side ft N/A N/A N/A
Side ft N/A N/A N/A
Rear ft N/A N/A N/A
Watercourse ft N/A N/A N/A
Site Coverage(maximum) 8,368 SF 7,770 SF 7,770 SF
see definition Section 12-2-2
Building Height(maximum) Sloping ft
see definition Section 12-2-2 Flat ft 33' 30' 33'
Landscaping Softscape sq ft N/A N/A N/A
See definition Section 14-2-1
Section 14-10-8 Hardscape sq ft N/A N/A N/A
TOTAL sq ft N/A N/A N/A
Driveway Max Curb-cuts N/A N/A N/A
Sections 14-3-1 & 14-3-2
Max Grade @
centerline N/A N/A N/A
Min Width N/A N/A N/A
Heated drive? I—Yes F No 1—Yes F No
Snow Storage% N/A N/A N/A
Parking #Enclosed Spaces
Sections 12-10& 14-5 #Unenclosed N/A N/A N/A
TOTAL
Outdoor Lighting (maximum) #fixtures
Section 14-10-7 N/A N/A N/A
14OF1'4/
PROPOSED MATERIALS
9-1
Building Materials Type of Material Color 4117O7
DRB
APPROVED
4/19/2017
12:00:00 AM
Roof SHAKE SHINGLES TO MATCH EXISTING
Siding VERTICAL SIDING, WOOD TO MATCH EXISTING
Other Wall Materials STUCCO TO MATCH EXISTING
Fascia WOOD TO MATCH EXISTING
Soffits WOOD TO MATCH EXISTING
Windows WOOD CLAD TO MATCH EXISTING
Window Trim TO MATCH EXISTING TO MATCH EXISTING
Doors TO MATCH EXISTING TO MATCH EXISTING
Door Trim TO MATCH EXISTING TO MATCH EXISTING
Hand or Deck Rails METAL TO MATCH EXISTING
Flues TO MATCH EXISTING TO MATCH EXISTING
Flashing COPPER TO MATCH EXISTING
Chimneys SIDING TO MATCH EXISTING
Trash Enclosures N/A N/A
Greenhouses N/A N/A
Retaining Walls N/A N/A
Exterior Lighting N/A N/A
Other N/A N/A
Notes:
Please specify the manufacturer's name, the color name and number and attach a color chip.
OF,
PROPOSED LANDSCAPING
Botanical Name Common Name Quantity
PROPOSED N/A N/A N/A N/A 00
TRS
DRB
AND SHRUBS APPROVED
4 11 912 01 7
12:00:00 AM
EXISTING TREES N/A
TO BE REMOVED N/A
Minimum Requirements for Landscaping: Deciduous Trees—2" Caliper
Coniferous Trees—6' in height
Shrubs—5 Gal.
Type Square Footage
GROUND COVER N/A N/A
SOD N/A N/A
SEED N/A N/A
IRRIGATION N/A N/A
TYPE OF EROSION CONTROL N/A N/A
Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.)
N/A