HomeMy WebLinkAboutDRB17-0023_A0_1487712060.pdf *IA OF grA
,,,,F".
go
a
i �r
IS
Alin
DRB
APPROVED
2/15/2017
ABBREVIATIONS 12:00:00 AM
& AND MATL MATERIAL
< ANGLE MAX MAXIMUM
@ AT MECH MECHANICAL
# POUND(S)or NUMBER MEP MECHANICAL,ELECTRICAL and PLUMBING
AFF ABOVE FINISHED FLOOR MTL METAL
ASI ARCHITECT'S SUPPLEMENTAL MFR MANUFACTURER 01 . 23 . 2017
INSTRUCTIONS MIN MINIMUM
ABV ABOVE MIRR MIRROR
ACOUS ACCOUSTICAL MISC MISCELLANEOUS
ADD ADDENDUM MEMB MEMBRANE
ADJ ADJACENT or ADJUSTABLE MTD MOUNT(ED)
AGG AGGREGATE MUL MULLION
AHU AIR HANDLING UNIT MED MEDIUM
ALUM ALUMINUM MAG MAGNETIC
ALT ALTERNATE MM MILLIMETERS
ARCH ARCHITECTURAL MEZZ MEZZANINE
ASPH ASPHALT MB MOISTURE BARRIER LOT 45 GLENSTREAM
AUTO AUTOMATIC N NORTH
AD AREA DRAIN or ACCESS DOOR (N) NEW
APPROX APPROXIMATE NIC NOT IN CONTRACT
A/V AUDIO/VISUAL NTS NOT TO SCALE
AVG AVERAGE NO NUMBER
B.O.F. BY OWNER,FUTURE NOM NOMINAL
BD BOARD OA OVERALL
B.O. BY OWNER OC ON CENTER
BLDG BUILDING OD OUTSIDE DIAMETER
BIT BITUMINOUS OTO OUTSIDE-TO-OUTSIDE
BLKG BLOCKING OFF OFFICE 1255 WESTHAVEN CIRCLE
BM BEAM or BENCH MARK OH OPPOSITE HAND
BOT BOTTOM OPNG OPENING
NOT FOR CONSTRUCTION
BRG BEARNING OPP OPPOSITE
BSMT BASEMENT OF OUTSIDE FACE
B BASE PC PRECAST
CJ CONTROL JOINT PAC PREVIOUSLY AWARDED CONTRACT
CL COLUMN LINE P/L PROPERTY LINE J 6r-i
C.L. CENTERLINE I PLAM PLASTIC LAMINATEV I—
CIRC CIRCUMFERENCE PSF POUNDS PER SQUARE FOOT Z
co
G
CAB CABINET I PSI POUNDS PER SQUARE INCH VAIL CO 81657
C CAULKING PT POST TENSIONED or PORCELAIN TILE
CFL COUNTERFLASHING PVC POLYVINYL CHLORIDE _
=
_
CM CENTIMETERS PLYWD PLYWOOD IZ Z �
CMU CONCRETE MASONRY UNIT PREFAB PREFABRICATED
CO CHANGE ORDER or CLEANOUT PL PLATE
CT CERAMIC TILE PLAS PLASTER
,...)
CEM CEMENTITIOUS PNL PANEL = O
CK CORK TILE P PAINT(ED) I— Z J
CLG CEILING PR PAIR or PROPOSAL REQUEST . .
CLOS CLOSET PROJ PROJECT
CLR CLEAR PTN PARTITION
CLR COUNTER PVMT PAVEMENT EXTERIOR ELEVATION IDENTIFICATION WINDOW IDENTIFICATION , Ci—
COL COLUMN PRESTR PRESTRESSED CODE:
CONC CONCRETE PBO PROVIDED BY OTHERS _ SHEET INDEX SCALE I� J
CONSTR CONSTRUCTION
PAR PARALLEL DRAWING NUMBER
CONT CONTINUOUS PREFIN PREFINISHED A4.01 SHEET NUMBER (Cl 7. WINDOW TYPE
CONTR CONTRACTOR I POL POLISHED INTERNATIONAL RESIDENTIAL A000 COVER SHEET NTS.
CORR CORRIDOR or CORRUGATED PLBG PLUMBING CODE 2012
CPT CARPET PKG PARKING INTERIOR ELEVATION IDENTIFICATION KEYNOTE IDENTIFICATION
CONN CONNECTION I PERIM PERIMETER TOPOGRAPHIC SURVEY 1"=10'
CATV CABLELOSCIRCUIT N PERFRPERFORATED 99� _ DRAWING NUMBER ZONING.
CCTV CLOSED CIRCUIT TELEVISION PRIM PRIMARY •
CU CUBIC PT POINT OF TANGENCY LANDSCAPE
CY CUBIC YARD QTY QUANTITY 99 A7.01 99 NOTE NUMBER 7.--1 71"-1
71P-1
7.-1 7.--1
DEG DEGREE QT QUARRY TILE SHEET NUMBER4 2 FAM LY RESIDENTIAL/ SDD(INCLUSI•NARY) L 1.0 LANDSCAPE SITE PLAN 1/8"=1'-0"
DAMP DAMPROOFING (R) REMOVE 99 A A A i L 2.0 LANDSCAPE PLANTING PLAN 1/8"=1'-0"
DBL DOUBLE R RISER REVISION IDENTIFICATION DTL DETAIL RD RAIN LEADDRAIN or ROAD DETAIL IDENTIFICATION C P C C L SS !CATION :DIA DIAMETER RL RAIN LEADER ill ARCHITECTURAL
DIM DIMENSION RO ROUGH OPENING
DN DOWN ROD ROOFOFOVERFLOW DRAIN Ai— DRAWING NUMBER A 1 BASEMENT FLOOR PLAN 1/4"=1'-0"f REVISIONNUMBER
DR DOOR RWC RAIN WATER CONDUCTOR 001\ TYPE R DIVISION 3 (SPRINKLERED) A 2 MAIN LEVEL FLOOR PLAN 1/4"=1'-0"
DS DOWNSPOUT RAD RADIUS A9.01 - SHEET NUMBER ASI f
DWG DRAWING RE REFER TO or REFERENCE REVISION DESCRIPTION A 5 ROOF PLAN 1/4"=1'-0"
DWR DRAWER REINF REINFORCED A 6 EXTERIOR ELEVATIONS 1/4"=1'-0"
DIV DIVISION REC RECESS(ED) PROJ ECT TEAM A 7 EXTERIOR ELEVATIONS 1/4"=1'-0" ,
DIAL DIAGONAL REF REFRIGERATOR or REFRIGERATED A 8 SITE LIGHTING PLAN 1/4"=1'-0"
DEMO DEMOLISH or DEMOLITION READ REQUIRED
EJ EXPANSION JOINT RESIL RESILIENT OWNER LANDSCAPE A 9 GRFA CALCS 1/8"=1'-0" •
(E) EXISTING REV REVISE,REVISED or REVISION(S)
EB EXPANSION BOLT RFG ROOFING WALL SECTION IDENTIFICATION WESTHAVEN LLC AND CERES+ `''F
E EAST RFL REFLECTED SECTION MATERIAL JANIE LIPNICK PO BOX 2134
EA EACH RM ROOM GRAPHICS 1255 WESTHAVEN CIR. EAGLE, CO 81631 -
EL ELEVATION ROW RIGHT OF WAY
r1
ELEC ELECTRICAL RBS RUBBER BASE STRAIGHT DRAWING NUMBER VAIL, CO 81657 JO
ELEV ELEVATOR RBC RUBBER BASE COVE A5.11 - SHEET NUMBER P:VOICE P:970-949-3286
EMER EMERGENCY RB RUBBER BASE
\ CONCRETE F:FAX F:970-262-2162 R,
ENGR ENGINEERRH RIGHT HAND 4
_
EOS EDGE OF SLAB RF RESILIENT FLOORING p ARCHITECT SURVEY
EQ EQUAL RECPT RECEPTACLE
KH WEBB ARCHITECTS O SHEET INDEX ..,
EQUIP EQUIPMENT RBT RUBBER TILE EAGLE VALLEY �� _ ��
EXT EXTERIOR RVS REVERSE(SIDE) 710 WEST LIONSHEAD 3 1 -0 CU
ES EACH SIDE SPRT SUPPORT - UNDISTURBED OR SURVEYING
EWH ELECTRIC WATER HEATER 1 COMPACTED EARTH CIRCLE CO
UNIT PO BOX 1230
S SOUTH or SEALED VAIL, 47 81657 EDWARDS, CO 81632 4,
EW EACH WAYBUILDING SECTION IDENTIFICATION P:970-949-1406
SC SOLID CORE P:970-477-2990
EST ESTIMATE SSK SERVICE SINK F:970-477-2965
FAC FIRE ALARM CABINET SS STAINLESS STEEL I POROUS FILL
FA FIRE ALARM SR SINK RECEPTACLE A
-' DRAWING NUMBER (GRAVEL) CONTRACTOR SOILS
FBO FURNISHED BYOTHER(S) SCHED SCHEDULE A5.01 �� SHEET NUMBER
FD FLOOR DRAIN or FIRE DAMPER SEC SECTION HP GEOTECH
FFL FINISHED FLOOR LINE SHWR SHOWER V VAIL CUSTOM
FR FIRE RESISTIVE or FIRE RATED 5020 COUNTY RD. 154
SHT SHEET BUILDERS
GLENWOOD SPRINGS, :
STEEL PO BOX 2809 CO 81601
FDN FOUNDATION SHTG SHEATHING CONTACT:TED LEACH
FIN FINISH(ED) SIM SIMILAR P:970-945-7988
FIXT FIXTURE SPECS SPECIFICATION(S) EDWARDS,C0 81632
FLG FLASHING SQ SQUARE F:970-945-8454
FLR FLOOR(ING) SF SQUARE FEET
FLUOR FLUORESCENT STL STEEL ALUMINUM
FRT FIRE RETARDANT TREATED STA STATION ENLARGED DETAIL IDENTIFICATION i RADON MITIGATION .
FT FOOT(FEET) STD STANDARD
FTG FOOTING STOR STORAGE 1— AREA OF DRAWING TO
FUER FURRED or FURRING STRUCT STRUCTURE or STRUCTURAL BE ENLARGED
FUT FUTURE SUSP SUSPEND(ED) MASONRY- BRICK TO COMPLY WITH 1 RC 2012- DRAIN-TILE AND STUB OUT UNDER SLAB
FF FINISHED FLOOR SYM SYMMETRICAL
FURN FURNISH(ED) SYS SYSTEM T AND GRAVEL 6 MIL. VISQUEEN OVER GRAVEL. PERIMETER SEAL WI
FOM FACE OF MASONRY SOFF SOFFIT ONE PART POLYURETHANE CAULKING. INSTALL RADON FAN & NEC-
FOF FACE OF FINISH SPKR SPEAKER 1 DRAWING NUMBER MASONRY
FOS FACE OF STUD SPKL SPRINKLER ESSARY PIPING TO CONNECT DIFFERENT ELEVS. EXACT LOCATION
FOC FACE OF CONCRETE T&B TOP AND BOTTOM A6.01 - SHEET NUMBER CONCRETE BLOCK OF PIPES TBD BY CONSULTANT PER SITE VISIT. ALL ENTRY ROUTES w w w
GWB GYPSUM WALLBOARD T TREAD
GC GENERAL CONTRACTOR T&G TONGUE AND GROOVE SHALL BE SEALED W/ONE PART POLYURETHANE CAULKING DAMP- J J
GYP.BD. GYPSUM BOARD TB TOWEL BAR PROOFING ON ALL PORTIONS OF CONCRETE & MASONRY FDN WALLS u i U U U
GA GAUGE TO TOP OF DOOR IDENTIFICATION RIDGID INSULATION BELOW GRADE PER IRC. Z
GR GRADE TPTN TOILET PARTITION
GL GLASS or GLAZING TV TELEVISION 0 w r ,
GND GROUND TELE TELEPHONE v
GALV GALVANIZED THK THICK or THICKNESS 0 z 0
GYP GYPSUM THLD THRESHOLD BATT INSULATION z Z
GT GLASS TILE TYP TYPICAL (308) DOOR NUMBER ESNE
Lu Lij
GRT GROUT TEMP TEMPORARY or TEMPERATURE W
rn \
GI GALVANIZED IRON TG TEMPERED GLASS L J / /
HM HOLLOW METAL TBC TOP OF BACK OF CURB
HDR HEADER TS TUBE STEEL .' - z n 12
I
. ".
HDWR HARDWARE TOW TOP OF WALL
GYPSUM PLASTER I— I-
HT HEIGHT TOS TOP OF STEEL ROOM/SPACE/AREA IDENTIFICATIONOw w
HORIZ HORIZONTAL TOC TOP OF CONCRETE
HR HOUR THERM THERMOSTAT Ur 1
HVAC HEATING,VENTILATION and AIR UL UNDERWRITER'S LABORATORY y
CONDITIONING ROOM NAMELLI
UON UNLESS OTHERWISE NOTED ROOM NAME v PLYWOOD
HB HOSE BIB UOS UNLESS OTHERWISE SPECIFIED
Z
HDAS HEADED DEFORMED ANCHOR STUD UNFIN UNFINISHED 314 ROOM NUMBERLO Lo
HAS HEADED ANCHOR STUDV VOLT 11 0_
HWH HOT WATER HEATER VB VAPOR BARRIER 876.00 SF— ROOM AREA N
HW HOT WATER VCT VINYL COMPOSITION TILE
HTR HEATER \\\\\ FINISH WOOD N
ID INSIDE DIAMETER VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
IN INCH(ES) VERT VERTICAL PARTITION TYPE IDENTIFICATION
INFO INFORMATION VEST VESTIBULE
INSUL INSULATION or INSULATED VIN VINYL or SHEET VINYL
INT INTERIOR VAR VARY or VARIES 23A - PARTITION TYPE; RE:
INCAND INCANDESCENT VIF VERIFY IN FIELD PARTITION TYPE SCHEDULE N o. Description Date
INV INVERT VER VERIFY
INCL INCLUD(ED) VENT VENTILATION
JST JOIST
JT JOINT VOL
WD WOOD VOLUME 1 Revision 1 Date 1
KP KICK PLATE W WEST or WIDE ACOUSTICAL PARTITION TYPE IDENTIFICATION FINAL DRB SUBMITTAL 01.23.2017
KIT KITCHEN W/C WATER CLOSET
KO KNOCKOUT WPT WORKING POINT
LH LEFT HAND — 76H PARTITION TYPE; RE:
LLH LONG LEG HORIZONTAL W/R WATER RESISTANT PARTITION TYPE SCHEDULE
WWF WELDED WIRE FABRIC
LLV LONG LEG VERTICAL W/ WITH
LAB LABORATORY W/O WITHOUT STRUCTURAL GRID
LAM LAMINATE WF. WIDE FLANGE or WOOD FLOORING
LBL LABEL WDO WINDOW
LT LIGHT WP WATERPROOF(ING) A — COLUMN LETTER
LTL LINTEL WSCT WAINSCOT
LVR LOUVER WC WALL COVERING
LDR LEADER WT WEIGHT
1
LP LIGHTING PANEL or LIGHT PROOF
W.O. WHERE OCCURS
MO MASONRY OPENING
MAS MASONRY WGL WIRE GLASS COLUMN REFERENCE
YD YARD N GUIDE
COLUMN LETTER
ELEVATION DATUM IDENTIFICATION Project Number 2511
-- LEVEL NAME Date
-'". _ ELEVATION Drawn By Author
OGRAPHIC STANDARDS COVER SHEET
3" = 1'-0"
2
a
A000 ,
L.0d
co
N-
O
Scale 3" = 1 '-0"
03N