HomeMy WebLinkAboutDRB17-0023_A9_1487712060.pdf OF ,'4
a
01
fa it
4Cij I Ill 011°116%
DRB
APPROVED
2/15/2017
12:00:00 AM
„.____ _
OUTLINE E FOOTPRINTREPRESENTS FOR F
OUTLINE REPRESENTS ` O
SITE COVERAGE * \ /
HOUSE FOOTPRINT FOR ` I I -- I I
SITE COVERAGE :_-_--
O
rimi
1 11
pirmuwad 1
. ,
.. ... ...„ .
•I I rilliri
_, =i__-1.—_
\411,°1\1411, _
, ,
- .I NOT FOR CONSTRUCTION
.4) 1 1 ,
, I." 4
._ � --
III
��� t
__11\ gl 1 { I I • Limo=
• ■I Area
L I ■III■
.I 2812.96
W 1�
■ 71/ I SF J �.,
■E_
/
a =.
co
II Area / , `�
�- 1-- ,II I_ , ' 2646.07 / i,_
/ . 1
SF ,_ —�
�� 0 _ = -
�_ �� �T/ - _�'
���
i , ,,,
II 1 ,
iI 1— =
I,
I- 1 �-,
P I .
CI
1: J
OUTLINE REPRESENTS ❑
��
HOUSE FOOTPRINT FOR � i 0
SITE COVERAGE II
Area III N
9SF4N 8 lqij411 / ' ,
II
/ .11
II m 11 13
rl N•
// J
) ®
\iii,.T,op .
Area
699.23
STORAGE ° ./
SF
1/8" = 1'-0" �
IM
OUTLINE REPRESENTS N / *
HOUSE FOOTPRINT FOR
SITE COVERAGE
OLOWER LEVEL-T.O. SLAB3 , MAIN LEVEL-T.O. PLYWD
1/8" = 1'-0" 1/8" = 1'-0" —:
DOWNSPOUT
LU
I-a0 UTT51�39t NSPOTI TAEAT TAPE
13 - s 43' 0 1/32"
o o
LL
T
1
1/4"PER,�FT L.,
KOUF SLOPE ROF �J w U EL TRELLIS BELOW
p 0 o DECK BELOW
O o I o o \ J Ii J J
I Wv
1 1 , 1 1 I I ZONING ANALYSIS: U
-N 1
O �ERESToI ��I DOWS i O CLERESTORY WINDOW 0 LOT 45, GLENSTREAM W U U
v LL E� RR 0I
Illr‘ Z 0 z Z
IrO �O rO rO °p DECK BELOW
-> _� li I w w CO 433 SQ/FT/ BELOW GRADE
gyTOF < 1/4"f CRT ��iOF < VAIL,
ROOF SLOP ROOF SLOP 493 SQ/FT TOTAL WALL AREA w
aj
:'0 0 a STEEL TRELLIS BELOW
CO n
�°� p p p p 1 _ 0 LOT SIZE. .4383 ACRES/ 190 ,092 SQ/FT BASED ON EAGLE COUNTY ASSESSORS RECORDS �+/ >
•_ LL Ill
w Q
0 ZONING: SDD/TWO FAMILY/ PRIMARY SECONDARY RESIDENTIAL ZONING z = iQ
I I STANDING SE`M i CC
METAL ROOF/14"WIDT SETBACKS: 20' FRONT 11
PANELS 18' 7 9/16" �/ W
2'-6" I 2'-6" W 15' SIDES
7 F 15' REAR7 WU.1 iw
I I CLERESTORY WINDOWS------ — .. Li
i- HEIGHT: 33 SLOPED ROOF/30 FLAT ROOFSSTANDING SEM -
METAL ROOF/14"MPH IH
PANELS > I•
LANDSCAPING: 11,455 SQ/FT REQUIRED 960%OF TOTAL SITE AREA) 708 SQ/FT/ BELOW GRADE ^ L(7
CUTTER&DoWN .' H MECH C> 3OF Q 1/4"IPCR/FT > SOF < 1/4"F CRifT DECK BELOW L.L
`- ';3a� �T +� 9 708 SQ/FT TOTAL WALL AREA CV N
Lr _ . 2 PIPE CNO(�JCUARD y e;,. D 5&�- CHASE ROOF SLOPE n ROOF SLOPE I
JJ •^ — o - - PARKING: 5 SPACES REQUIRED IF BUILT OUT TO MAXIMUM SIZE J r
' 0
co
N` CUTTER&DOWNCPOU I!I aT_TAh- A o GRFA: TOTAL ALLOWABLE: 7,032 OF GROSS RESIDENTIAL FLOOR AREA(GRFA)
0
DOWNSPOUT EC
ITEMS NOT INCLUDED IN ABOVE NUMBERS:
p 300 SQ/FT PER ENCLOSED GARAGE SPACE UP TO 2 PER DWELLING UNIT.
1/4"-P /FT �i�F < 22'-4 29/32"
FOOF SLOP'nl+- IN / / ATTICS LESS THAN 5' IN HEIGHT. ATTICS ONLY ACCESSIBLE FROM THE FLOOR BELOW.
STEEL TRELLIS BELOW u a BASEMENTS BELOW GRADE,ABOVE GRADE PORTIONS WILL COUNT PROPORTIONALLY.
❑ o o VAULTED SPACES ABOVE 16'IN HEIGHT(THESE SPACES ARE COUNTED TWICE) 603 SQ/FT/ BELOW GRADE No. Description Date
LL
SITE COVERAGE: TOTAL ALLOWABLE IS 3,818 SQ/FT( 20%OF TOTAL SITE AREA)ALLOWED 904 SQ/FT TOTAL WALL AREA 1 Revision 1 Date 1
co
3 615 SITE COVERAGE USED/203 SSQ/FT OF SITE COVERAGE REMAINING
:S-fcricilE
N 12 .
r FINAL DRB SUBMITTAL 01.23.2017
rE-)
MOF < 1/4"PERI-,� ROOF SI ' 'E
°0 • LOWER LEVEL BASEMENT GRFA CALCS:
Ao` 3744 SQ/FT TOTAL WALL AREA- FIN. FLOOR TO UNDERSIDE OF FLOOR STRUCTURE: 3744 SQ/FT
i 9 RF� CE• F inti 1043 SQJFT OF WALL BELOW GRADE=D
27% 0 SQ/FT/ BELOW GRADE
27%OF LOWEST LEVEL GRFA TO BE DEDUCTED FROM CALLS
'7� 0,0 �`�' 601 SQ/FT TOTAL WALL AREA
7i2,
Q� ^� 50e�\ �\�cl, Ac?5)
�00� PROPOSED GRFA CALCULATIONS:
NO ROOF OVERHANGS OVER 4' 0" O� �` ,j
�/•o� 4.,/04:•�°� LOWER LEVEL: 2646.07 SQ/FT
�ti SOD ROOF STORAGE/ MECH.: 946.68 SQ/FT
LESS THAN MIXT RE Project Number
%,,,,..,;(:., �`L MAIN LEVEL WITH MUD ROOM: 2812.9 SQ/FT2511
\ �,�� 2 �oHT. OVER 16' 0": 83 SQ/FT3 0
:0!E�, 77, �S<op� Date
NET SQ./FT: 6,488.65 SQ/FT
.,0'y'Y 0 SQ/FT/BELOW GRADE
(0 GARAGE DEDUCTION: -600 SQ/FT 1038 SQ/FT TOTAL WALL AREA Drawn By Author
i
GARAGE SQ/FT: 699 SQ/FT
•41:2, TOTAL GARAGE WITH DEDUCTION: 99 SQ/FT
SOD ROOF
LESS THAN 8"'•IL MI.TUR
BASEMENT DEDUCTION: -970 SQ/FT GRFA CALCS
,1'o
°<s�. TOTAL GRFA: 5617 SQ/FT
°OF GRFA REMAINING: 1415 SQ/FT
ROOF-OVERHANGS ...Al& ...AI&...Alk BASEMENT WALL CALCS
1/8" = 1'-0" T T I 1 T1/8" = 1'-0"
EXISTING DUPLEX GRFA CALCULATIONS:
4,3873 SQ/FT(UNIT A) +2,477 SQ/FT(UNIT B)= 6,873 SQ/FT
• PROPOSED NET SQ/FT"
d
6405 SQ/FT( LIVING AREAS, NO GARAGE, NO DEDUCTIONS) A9
co
THE PROPOSED SINGLE FAMILY RESIDENCE IS 468 SQ/FT SMALLER M
THAN THIS EXISTING DUPLEX(UNIT A&B)
N-
0
Scale 1/8" = 1 '-0"
N