Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB17-0058_cut sheets_1488320820.pdf
V i _ , • ,i ,, t r CanadianSolar „. 1 � ,, ; -- --- CS6 P-260 1265P-SD Optimized by solar- • • --- - -, -*- Canadian Solar Smart DC module features an innovative integration of Canadian Solar's module technology and SolarEdge's power optimization __ _ for grid-tied PV application. By replacing the traditional junction-box with a to --- --+----;-- SolarEdge power optimizer,the Smart DC module A optimizes power output at module-level.With this (,�= - feature,the Smart DC module can eliminate the f module-level mismatch and decrease shading losses. Furthermore,the Smart DC module provides *Optional black backsheet module-level data to minimize operational costs available upon request and allow effective system management. KEY FEATURES 25 ” insurance-backed warranty years non-cancelable,immediate warranty insurance %Harvest up to 25%more energy """ linear power output warranty 25% from each module • Maximizes power from each individual ' 10 N. product warranty on materials module against potential mismatch risk years s and workmanship • Decreases shading losses • Reduces cell series resistance MANAGEMENT SYSTEM CERTIFICATES* Easy installation,simple system design ISO 9001:2008/Quality management system l • Integrated smart solution, no need to ISO/TS 16949:2009/The automotive industry quality management system add other accessories ISO 14001:2004/Standards for environmental management system • Enhances the shading tolerance OHSAS 18001:2007/International standards for occupational health&safety • Longer and uneven string using SolarEdge inverter cell-level stress PRODUCT CERTIFICATES* release technology IEC 61215/IEC 61730:VDE/CE UL 1703/IEC 61215 performance:CEC listed(US) Reduced BoS Costs UL 1703:CSA Up 1 - kW per stringC G.s� allows foror moror e moo dules based on e _'_ ' " ovET; different inverters *As there are different certification requirements in different markets,please contact your Canadian Solar sales representative for the specific certificates applicable to the products. Free module level monitoring system 0 • Full visibility of system performance • Free smart phone app for CANADIAN SOLAR INC.is committed to providing high quality the monitoring system solar products,solar system solutions and services to customers around the world.As a leading manufacturer of solar modules and MORE More Safety PV project developer with about 10 GW of premium quality Aik • Automatic drop of DC current and modules deployed around the world since 2001,Canadian Solar voltage when inverter or grid power Inc.(NASDAQ:CSIQ)is one of the most bankable solar companies is shutdown worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph, Ontario Ni K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com MODULE/ENGINEERING DRAWING(mm) CS6P-265P/I-V CURVES A A Rear View Frame Cross Section 10 _ _ _ 10 '411. 9- ..............._ 9........................................................................... ........................... a�umwum FRAME[ I :L a-ABB • ' se ❑. X35= 6. 6............................................................................................................. ' 1 tli::: 0 V O V 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 I • 1000 W/m� 5°C ■ �I}'M • 800 W/m' 25°C ■ • 600 Wm' 45°C • • 400 Wm 65°C ■ ELECTRICAL DATA/STC* MODULE I MECHANICAL DATA Electrical Data CS6P Specification Data Power Optimizer connected to a Cell Type Poly-crystalline,6inch SolarEdge Inverter 260P-SD 265P-SD Cell Arrangement 60(6x 10) Nominal Max. Power(Pmax STC) 260 W 265 W Dimensions 1638x982x40 mm(64.5 x38.7x 1.57 in) Nominal Max. Power(Pmax NOCT) 189 W 192 W Weight 19.7 kg Open Circuit Voltage(Voc STC) 37.5 V 37.7 V Front Cover 3.2 mm tempered glass Output Voltage Range(Vout) 5-60 V 5-60 V Frame Material Anodized aluminium alloy Max.Output Current(Imax) 15 A 15 A J-Box IP65 Max.Series Fuse Rating 15 A 15 A Cable PV1-F 1*6.0 mm2/950 mm Module Efficiency 16.16% 16.47% Connectors MC4 Output During Standby Standard Packaging 26 pieces (power optimizer disconnected 1 V Module Pieces from inverter or inverter off) per Container 728 pieces(40'HQ) PV SYSTEM DESIGN TEMPERATURE CHARACTERISTICS Specification Data 1 ph 8 Temperature Coefficient(Pmax) -0.41%/°C EU 3 ph 16 Temperature Coefficient(Voc) -0.31%/°C Min.String Length 3 ph-MV 18 Temperature Coefficient(Isc) 0.053%1°C US 1 ph 8 Nominal Operating Cell Temperature 45±2°C 3 ph(280 V) 10 1 ph 20 19 STANDARD COMPLIANCE EU 3 ph 43 42 EMC FCC Part15 Class B, Max.String Length 3 ph-MV 49 48 IEC61000-6-2,IEC61000-6-3 1 ph 20 19 PV Optimizer Junction Box EN50548,UL3730,IEC2109-1 US 3 ph(280 V) 23 22 (class II safety), UL1741 1 ph 5250 Fire Safety VDE-AR-E 2100-712:2013-05 EU 3 ph 11250 Max.Power 3 ph-MV 12750 PARTNER SECTION per String(W) 1 ph 5250 US 3 h(280 V) 6000 Parallel Strings of Different Lengths Yes Parallel Strings of Different Orientations Yes Operating Temperature -40°C—+85°C Max.System Voltage 1000 V(IEC)/600 V(UL) Application Classification Class A Type 1(UL1703)/ Fire Rating Class C(IEC61730) Z L Scan this QR-code to discover solar 0 ,•r ❑ Power Tolerance 0-+5 W projects built with this module •. _ :elf. ti ■ o l�• CANADIAN SOLAR INC. August 2015.All rights reserved, PV Module Product Datasheet V5.3_EN ❑■ . E... •�. cc solar - • • W W SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 F. ,� Dower°, no i` Z. • //_� , ,,, / ,/ ,,, ,,, . .F f PV power optimization at the module-level — Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar - • • z SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 P300 P320 P400 P405 (for 60-cell modules) (for high-power (for 72&96-cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Powerhl 300 I 320 I 400 1 405 I W Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 I 8-80 I 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 I 11 I 10 Adc Maximum DC Input Current 12.5 I 13.75 I 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current I 15 Adc Maximum Output Voltage I 60 I 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 128x152x27.5/ 128x152x35/ 128x152x48/ mm/in 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 Weight(including cables) 770/1.7 I 930/2.05 I 930/2.05 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated;MC4 Compatible Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 °C/°F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % I'I Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2) Minimum String Length (Power Optimizers) 8 10 18 Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 I W Parallel Strings of Different Lengths or Orientations Yes mit is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE ETA ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2015 V.01.Subject to change without notice. ci) solar oc SolarEdge Single Phase Inverters CC For North America W SE3O00A-US / SE38O0A-US / SE5000A-US / SE600OA-US / SE76O0A-US / SE1O000A-US / SE114O0A-US \�verte, .12,25 Vear my 000 a 1°1130\' I 111 8 0 104 f The best choice for SolarEdge enabled systems • Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) — Small, lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter, DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us solar - • • z Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE10000A-US SE11400A-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA 10000 @240V• f • Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA 5450 @240V 10950 @240V AC Output Voltage Min:Nom:Max.ltl 183-208-229 Vac AC Output Voltage Min:Nom:Max.ltl 211-240-264 Vac AC Frequency Min.-Nom.-Max.l'i I 59.3-60-60.5(with HI country setting 57-60-60.5) 1 HzMax.Continuous Output Current 12.5• 16 21 @ 240V 25 32 42 @ 240V 47.5 A • GFDI 1 1. A Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes ( Yes INPUT Recommended Max.DC PowerlZl 3750 I 4750 1 6250 1 7500 I 9500 I 12400 1 14250 W °(STC) Transformer-less,Ungrounded Yes Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc 08V Max.Input Currentl3l 9.5 I 13 115.5 @ 240V I 18 I 23 I 3035 @2240V I 34.5 Adc • Max.Input Short Circuit Current 45 1 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600ko Sensitivity • Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % • CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V 97.5 1 98 @ 240V 97.5 @ 240V • Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) .Revenue Grade Data,ANSI C12.1 Optionall4l Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installedlsl STANDARD COMPLIANCE Safety UL1741,UL1699B,UL1998,CSA 22.2 Grid Connection StandardsIEEE1547 Emissions FCC partly class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range I 3/4"minimum/16-6 AWG I 3/4"minimum/8-3 AWG DC input conduit size/#of strings/ AWG range 3/4"minimum/1-2 strings/16-6 AWG 3/4"minimum/1-2 strings/14-6 AWG • Dimensions with Safety Switch 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 30.Sx12.5x10.5/775x315x260 in/ .(HxWxD) 775x315x172 775x315x191 mm . Weight with Safety Switch 51.2/23.2 54.7/24.7 88.4/40.1 lb/kg Cooling Natural Convection Fans(user replaceable) Noise <25 <50 dBA Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version availablelb)) "F PC Range , Protection Rating NEMA 3R ° • iri For other regional settings please contact SolarEdge support. Pi Limited to 125%for locations where the yearly average high temperature is above 77'F/25'C and to 135%for locations where it is below 77'F/25°C. For detailed information,refer to http://www.solaredge.us/files/pdfs/inverter_dc_oversizing_guide.odf MA higher current source may be used;the inverter will limit its input current to the values stated. 141 Revenue grade inverter P/N:SExxxxA-US000NNR2 Isi Rapid shutdown kit P/N:SE1000-RSD-S1 161-40 version P/N:SExxxxA-US000NNU4 0:0 COM Ro H S ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07/2014.V.01.Subject to change without notice. Ez Roof Mount. . . Engineered and Designed for easy installation. Our roof mounting system is water tight and durable for any composite/shake roof! -1--.1•- •'Pt ,e,,:.., ...4r 1 .- - -`40: , _,0,.-..,,,,w- - . '-. •••: ..,.:;•,.., • • 4,.„..... w...%. , .. -•;•• . - .. ..r... .p. ,-,:. ,--,64-f;,' ' ••! . 4'.•- ' ' ' ' '" — ',.. ,,‹ . :. • 7 . ' , --. .411W` /, • ' ...,, N_- . .V-,,,r,..!.. ..4,r'...,•-irry • -4.,_..4.A .- titq.'. - - , -'••..42.7,,,,1- . --:.- . •`.4. 4:i _ °'--k,um,8 • • ir •4• 1 -44, •:. $ '44 - 13.,,,4. •r'''' ,i 314. . -' - . IWAII\ ' • Oil to.A.4::,r 0 7-2' s•-:-..7 •.7., 4 1., I. 4;la.:".'" (Pk- 'x ...::'"-:, .- - / .. ,,,,, -. es 0 , '! •' i % A .' k.4",474, • •••••. -.• I • ...... ' '.;_*-':`" .t.. ,..,-•:„..:: *, '4?. ..; 144c 4,•.,•..***•;• --- !&• 4- :;:.- •---.••:' t. r •,,pkohe„,..7.1,• „, .• - t.Viity*...".. = .Aws:1-7416.71.141F-V-Ak t*T" !--..-*-_is"--",.-N-2..•.% • - • • --- - er,e,..Wer'''' .?"7‘.*•••'7'.14 e`-'':e!.••:*,.; " ' - - ' .-- '•-•:•-•i• '-. - A ra".etA` .1."4'1%t•es:_ Serrated L Foot allows for Versatile aluminum base for Flashing designed to redirect rail mounting on either multiple configurations. water flow. side. LI! --_ 1"" Ez Mount L-Foot Kit for Shingle Roofs Kit# K10068-001 All kits come complete with the following parts: - 1-Lag Bolt SS 5/16 x 4 1-Al Shoe Part#B15015-002 1 Part#A20065-001 4 kit--waTh .4.!* * `'• 1_Ez L Foot Part#A20064-001 Oft qa '.4411k- "7 ..14, 1- Flashing 1- Hex Cap 1- Bolt 3/8-16 x 3/4" Part#A20052-001 Pait#A20066-001 1- Flange Nut 3/8" Also available: t'l-• ..:'..'''',;)' iluilitoillp ,::.• -,,_-, . I ---- - e'L''•...,: IMI ' 4..- .,, . .. . ., . ;N- . ;1',t• -.... -:-:':)-:'-3., -,-•...... - • .;'.' -.:'` ...--,- .1`:'-`'. •-, .-‘, . :i ',"!--, * . . . • , 0 1905 E 5th St., Ste. A Vancouver, WA 98661 Phone: 360-844-0048 www.sunmodo.com