Loading...
HomeMy WebLinkAboutDRB17-0060_S-2_1491498039.pdf „F„Noort.04„ ROOF PLAN i '. .1.., ,„,- iv . . — 1-1, , . . — 0 DRB APPROVED 4/5/2017 12:00:00 AM PLAN NOTES: I. ROOF SHEATHING IS 5/8” PLYWOOD OR OSB APA RATED, EXPOSURE I, RATING 32/16. STAGGER END JOINTS AND FASTEN ACCORDING TO 2003 IBC FASTENING SCHEDULE (TABLE 2304.9.1) 2. ALL ROOF JOISTS ARE: BCI II 7/8" 6500 SERIES OR MANUFACTURED TRUSSES SPACED AT 24" o.c., TYPICAL, UNLESS NOTED OTHERWISE. 3. ALL LOOKOUTS SHALL BE 2x6's AT 24" o.c., TYPICAL, UNLESS NOTED OTHERWISE. O Z 4. SIMPSON H5 HURRICANE TIES SHALL BE INSTALLED AT ALL RAFTERS AND/OR TRUSSES AND LOOKOUTS / AT EXTERIOR WALL BEARING LOCATIONS. /AI 5. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2x6 STUDS SPACED AT 16" o.c., TYPICAL, UNLESS NOTED OTHERWISE - RE: EXTERIOR WALL CONSTRUCTION SECTION IN THE STRUCTURAL GENERAL I� NOTES, SHEET S I.I. ALL WALLS SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF (INCLUDING RAKE WALLS). STUDS LONGER THAN 16'-0" SHALL BE REPLACED WITH I%"xS" VERSA STUDS AS MANUFACTURED BY BOISE CASCADE CORPORATION. S. 6. EXTERIOR HEADERS: 6'-6"AND LONGER SHALL BE (3)-2x12 W/ (2)-2x6 TRIMMERS AND (I)-2x6 KING STUD. HEADERS 6'-5"AND SHORTER SHALL BE (3)-2x10 W/ (2)-2x6 TRIMMERS AND (I)-2x6 KING STUD, UNLESS NOTED OTHERWISE. HEADERS SHALL BE BUILT OUT TO WALL WIDTH BY ADDING PLYWOOD OR OSB Mao A203 SPACERS AS REQUIRED. `� 6 i \ \2/ 7. MINIMUM SUPPORT AT 6x AND LARGER BEAMS SHALL BE A (4)-2x6 COLUMN. 8. INTERIOR STRUCTURAL COLUMNS SHALL BE (3)-2x6 MINIMUM. �_ 111% , 2/ 9. ALL RAFTERS AND/OR TRUSSES SHALL BE ALIGNED TO BEAR WITHIN 5" OF STUDS BELOW. •`/�% iitp 4/ ' 7"� 10. ALL OVERFRAMING RAFTERS SHALL BE 2x6 MINIMUM AT 24" o.c.AND POSTED DOWN TO MAIN SUPPORT RAFTERS AT 4'-0" o.c., W/ (I)-2x8 RIDGE BOARD AND (I)-2x8 FLAT ALONG VALLEY LINE TO SUPPORT ENDS � OF RAFTERS, TYPICAL, UNLESS NOTED OTHERWISE. ry Wit DII1 I III 44444,..„ I I. "LVL" INDICATES: LAMINATED VENEER LUMBER BEAM AS MANUFACTURED BY BOISE CASCADE a: — CORPORATION. ALTERNATIVES SHALL HAVE THE SAME OR GREATER CAPACITIES AS THOSE LISTED IN ;' THE STRUCTURAL GENERAL NOTES, SHEET S1.1. drir../ - 8\ 12. WOOD BEAMS, EXCEPT HEADERS, ARE FLUSH WITH RAFTERS AND/OR TRUSSES UNLESS NOTED a' 4`' • (DROPPED). S� 41114411 SQ 1144 . =,4 13. RE:ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ROUGH OPENINGS IN WOOD STUD ,i , WALLS. a - / � e � ,/4 .,:" ,^■ 14. RE:ARCHITECTURAL DRAWINGS FOR ROOF SLOPES AND BEARING PLATE HEIGHTS. 15. REFER TO ARCHITECT FOR SNOW CLIP/GUARD PRODUCT INFO AND DETAIL. REFER TO ARCHITECTURAL ROOF PLAN FOR SNOW CLIP/ GUARD LOCATION. c vi CD I=::::::::::::1 „,,,%,4 '- i1 � ............................................ � � is „, _ n 77' ==eee ii .� __=_eem A202 r, . n n II- irall77.:” / -..... 1 :all-II- 111//:” �� 111/1* ..---- SUP Co DN r; I S4 I—i a G S-4 -• - - DN ,------ COI+,o 0Ol+Jo -- ---_-M _ - •/".."."- -"""""""""""`"......111111 ... ��i Fs— _4x14 D.F. No. 2 LEDGER ='4' _ T _ , . • : , = ;_ • -______`__ EXISTING STUD PACK- ■ I S �� I, I - k _ FIELD VERIFY ■■I t� i, , -- y , uu S-3 I I g 1 lI ci // II 7,1 8x8 KNEE BRACE 8x8 KNEE BRACE 8x8 KNEE BRACE I 1 T___ -� 10x12 D.F. No. 2 ® /._ 2✓10x12 D.F. No. 2 ® 10x12 D.F. No. 2 Alk 2 / 12'-5/8" / A201 KERRIGAN I) PROJECT: 100 E. MEADOW DRIVE JURISDICTION: SHEET NO.JOB NO. UNITS 7A, 8, 21 , 22 TOWN OF VAIL, CO STRUCTURAL FRAMING PLAN S-Z 16034 engineering c/1 0 12.01.16 PROGRESS SET P.O. Box 3032 • Eagle, Colorado 81631 c m NO. DATE REASON FOR ISSUING THIS DRAW/NG