Loading...
HomeMy WebLinkAboutDRB17-0074_A1.1_1491518880.pdf NO OF go 4"44, NEW METAL COMMERCIAL REMOVE EXISTING Li4itij THRESHOLD AT DOOR GRADE, ACCESSIBLE OPENING THRESHOLD AT DOOR PER IBC - 1010.1.7 AND 1010.1.5. RAISE _ - - - AS NEEDED WITH NEW CONC \ co TOPPING / in '°151'll i m APPROVED 4/5/2017 12:00: 0 A --z:- AM ANY MODIFICATIONS IN HEIGHT -1 III OF THRESHOLD SHALL NOT III RESULT IN A DOOR LESS THAN SLOPE/8"/FT TOWN OF VAIL STAMP 80" IN HEIGHT PER IBC 1010.1.1 . 111111 NEW METAL III GUARDRAIL, RE: 3/A1.2 _ 111. MA1.1 III SIM RESTACK/STRAIGHTEN III REMOVE EXISTING EXISTING WOOD RAILING SYSTEM PLANTER WALLS - REMOVE BOTTOM 3 --..i,/ NEW PAINTED EXISTING BRICKS AT I EXISTING REPLACE BOTTOM 3 EXISTINGMETAL DRIP EDGE. DECK/BRICK COLUMN PLANTER BRICKS AT DECK/BRICK PLANTER INTERSECTION I BED COLUMN INTERSECTION. BED — I REMOVE EXISTING MATCH EXISTING I MATCH EXISTING �__--- 1 TALLER GUARDRAIL 0. I , STAIR AND EXISTING 3'-11y2" POST, RE:1/A1.2 REMOVE BOTTOM 3I STAIR RAILING SYSTEM REPLACE BOTTOM 3 1�2'TYP EXISTING BRICKS AT BRICKS AT DECK/BRICK DECK/BRICK WALL I WALL INTERSECTION. T.O. NEW CONC - - INTERSECTION I II ���� MATCH EXISTING SLOPE Y"/FT TOPPING� I o A �0� p��L� P,OPE ARCHITECTURAL ANY MODIFICATIONS IN HEIGHT s ► _ � • \EN '\N P REMOVE EXISTING `� / GROUP, LLC OF THRESHOLD SHALL NOT , T.O. NEW CONC 14 1 1 I I SLOPE BENCH\ THRESHOLD AT DOOR I I \\\� RESULT INA DOOR LESS THAN / \Ara TOPPING I / I I I I I I ,� N \ co: OPENING PO BOX 1537 80" IN HEIGHT PER IBC 1010.1.1 REMOVE EXISTING TILE, I \ 63'-1Y°$I I I I I I UP 7R @ 6/" I \\\ EAGLE, COLORADO 81631 13"TINCL 1 ' CONC TOPPING, AND I I ® NEW HEATED STAIR WITH STAMPED, ___.1.1.1..11T13,_ I I WATERPROOFING I I \\\ (970)361-1393 ►• NEW METAL COMMERCIAL N Al2 Et `� COLORED CONC TOPPING. MATO EMEMBRANE. VIF IF I i '\\\ amy@s3ag.com GRADE, ACCESSIBLE NEW HEATED o I A �A EXISTING STAIR FOOTPRINT o - SUBSTRUCTURE IS -\\\ THRESHOLD AT DOOR PER IBC 4 .� \ STAMPED, I I � NEW METAL RAILIN oo DAMAGED BEYOND J L J - L -- \\ p \0l0.l.7AND 1010.1.5. RAISE WATERPROOFING �` �—-- �� S NEEDED WITH NEW CONC COLORED RE: 4/A1.2 MEMBRANELAYER OPPING CONCRETE `�� .1104-t � -0 -z_ TOPPING ON <2loroi EXISTING BRICKPLANTER �2 \ *-1- WATERPROOF 6 1**-6101% V< WALL TO REMAIN \\ \ MEMBRANE431.---; A1.2 `� Q . rvP \NREMOVE EXISTING \ /' kV �, N05/ .O. EXISTING STREET PAVER DECK FASCIA / 56'-2/2"-VIF -T EXISTING PLANTER NEW METAL ®�a 10 i EXISTING PLANTER BED vP - A\\ � ' REMOVE EXISTING BED \ GUARDRAIL/ HEATED STAIRS WITHIN THE RIGHT OF WAY \\ i „IFS NEW GUTTER SYSTEM HANDRAIL MUST BE ON A SEPARATE ZONE MARKED AT \ \ RAILING SYSTEM STAMP SLOP%/a WITH HEAT TAPE AND SYSTEM THE CONTROL BOX AS TOW OR ROW \\\ 00 OUTLET. PROVIDE TALLER GUARDRAIL0 \\\� DOWNSPOUT TO PLANTER POSTS, RE: 2/A1.2 REMOVE TOP 3 BRICKS NEW METAL BRICK WALL ON BELOW DECK FASCIA GUARDRAIL, STREET SIDE OF SIM RE: 3/A1.2 STAIR, BELOW TREAD SURFACE. BRICK TO MATCH EXISTING NORTH NORTH 0 EXISTING/PROPOSED DECK PLAN411) 0 EXISTING/DEMO DECK PLAN 4) > H Z O 1 2"x1 2" METAL TUBE 11 H HANDRAIL /2,Ns / H O '''ILI . NOTE: m ALL NEW METAL HANDRAIL AND < 6 O , ," 12"x3" METAL TUBE GUARDRAIL COMPONENTS TO METAL BRACKET BE POWDER COATED PRIOR TO WELDED TO RAILING BEING PAINTED TO MATCH NEW METAL GUARDRAIL SYSTEM, U RE: 3/A1.2 2 z O AND GUARDRAIL EXISTING AND INSTALLEDLLI J w co NEW S/"SQ METAL N PICKET ��������� 0 z H o z Oo I- LAP EXISTING BUILDING 1.1. QeLL \ % WATERPROOFING OVER NEW I I I WATERPROOFING SYSTEM (/) WwLU NEW BRICK- MATCH EXISTING z 0 0 0 NEW METAL RAILING PROVIDE WEEPS g w O Q WITH METAL POST EXISTING FRAMING iv PROTECTION BOARD OVERImil J fl BASE TO REMAIN NEW STAMPED CONC TOPPING, WATERPROOFING -TBD BY O J NEW STAMPED, AND WATERPROOF MEMBRANE. WATERPROOFING CONTRACTOR 0 0 5 COLORED CONCEXISTING STRUCTURE SLOPE%" PER FOOT TO GUTTER LIJ J J STAIRS, RE: STRUCTURAL TO REMAIN SLOPED BUILDUP%$" PER FT NEW WATERPROOF MEMBRANE BY M PER WATERPROOFING CARLISLE COATINGS ANDI— ,— > > /CONTRACTOR WATERPROOFING -TBD BY s WATERPROOFING CONTRACTOR ISSUE: l ^ 1NEW RADIANT HEATING SYSTEM, RE: NO DATE REMARKS NEW RADIANT HEATING �� �/ EXTERIOR /// MECH SYSTEM, RE: MECH 1 03/09/17 PRICING �INTERIOR f • 4 LL__-_ • SLOPE%" PER FT NEW METAL FLASHING 2 03/13/17 DRB SUBMITTAL = A ) • 4 NEW BRICK TO MATCH NO WORK �J // -� 3 03/28/17 DRB REVISIONS A EXISTING. PROVIDE �� ° . . ° ��,� /� 1 WEEPS 4 • � ° - - T.O. NEW CONC TOPPING • �' -• O ° 63.-1/8" PER STRUCTURAL ° NEW 2" EXTRUDED POLYSTYRENE INSULATION \1 4 A BOARD (XPS) /--\ 7--\ 7--\ 7� �N 7--\ =L__. - - /--\ /--\ /--\ /--\ /--\ 7--\ 7--\• \ \_ _ T.O. EXISTING CONC AT DECKING � �1 % %j FINISH GRADE, SLOPE AWAY \c tiunctociiirt • ` ///, COMPACTED FILL, TYP L 1 QI 1/7> n��. / NEW GUTTER SYSTEM TO MATCH d , If EXISTING FOR COLOR AND STYLE. NEW 1Y2"WASHED RIVER PROVIDE HEAT TAPE AND OUTLET. 1 ROCK FOR GRAVEL BASE DRAIN TO PLANTER BED BELOW ° SHEET NAME 4 '/ - NEW 8" CONCRETE WALL, I MAT/CHOOD TRIM - PAINT GRADE- DECK PLANS d ,', , RE: STRUCTURAL DETAILS , NEW BRICK- MATCH EXISTING • // / / PROVIDE WEEPS INTERIOR �� LAP NEW WATERPROOFING OVER LA d I --/ I NO WORK aO/ EXISTING BUILDING WATERPROOFING SHEET NUMBER 4 A I. / SYSTEM 4 ° I <1 / A1 . 1 1 PROPOSED GUARDRAIL/ HANDRAIL DETAIL PROPOSED DECK DETAIL 4 ix" , 1'-0° 1Y°= 1'-0" PROJECT NO: 1701