HomeMy WebLinkAboutDRB17-0094_A6_1490977020.pdfW.P.MEMBRANE OVER
SLOPING RIGID
INSULATION
R-35 BLOWN-IN
INSULATION TO FILL
9 1/4" STUD SPACE
T.O.PLYWOOD
8'-6" TO
SLAB
BELOW
9'-0" TO
SLAB
BELOW
5/8" DRYWALL
FINISH FLOOR
11 7/8" JOISTS
SHEATHING
2X14 BELLY BAND
METAL FLASHING W/ DRIP EDGE
DECKING PALETTES:
2X6 REDWOOD DECKING NAILED TO
2X4 SLEEPERS W/ RIPPED
(SLOPING) BOTTOMS.
PALETTES SIT ON MEMBRANE W/ NO
PENETRATIONS AND CAN BE
REMOVED FOR MAINTENANCE.
6X6 POST BEYOND
SEE RAILING DETAIL
8 1/8"
9 1/4"
6"
1' - 2"
1X4 T&G CEDAR SOFFIT
STEEL BEAM
SURROUND W/
SPRAY FOAM
INSULATION
2' - 1 3/4"
11 1/4"
1' - 2"
2X12 OUTRIGGERS
BLOCKING
R-56 BIBS INSULATION
COMPLETELY FILL 14" SPACE
NO VENTING
METAL ROOF
METAL FLASHING
12" FASCIA BOARD
(TO MATCH EXISTING)
1X4 T&G CEDAR SOFFIT
METAL PANEL SIDING
OVER W.P. MEMBRANE
R-22 BLOWN-IN INSULATION
5/8" DRYWALL
5/8" DRYWALL
12
2
Town of Vail amendment to the code:
Table C402.1.3 - Opaque Thermal Envelope Insulation Components Minimum Requirements, R- Value
Method: Table C402.1.3 is amended by the addition of the following:
"Wood framed and other may use R-21 in lieu of continuous insulation."
Section R402.2.11 - Heated Slab- On- Grade Floors: Section R402.2.11 is added, to read as follows:
"A minimum of R-10 insulation shall be installed under the slab extending horizontally from the exterior
wall of the building envelope for 4 feet."
1 1/2"
3 1/2" 2' - 2 1/2" 3 1/2" 2 1/2" 3' - 1 1/2"
3 1/2" 1 1/2" 5 1/2"
1 1/2"
2X2 PICKETS
2X4 TOP AND BOTTOM RAILS
2X6 TOP RAIL (SLOPE TOP)
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date REVISIONS
3/23/2017
5:05:08 PM
A6
DETAILS
xxxx
Harris
Renovation
PERMIT
SET
4-20-16
11-16-16
Harris
Family
2528
Arosa
Drive,
Vail, CO
Vail Das Schone
Filing 1, Block C, Lot 7 1" = 1'-0"
1
DECK DETAIL
1" = 1'-0"
2
ROOF SECTION
INSULATION SUMMARY
ALL MINIMUM INSULATION VALUES FROM
IRC 2015 TABLE N1102.1.2 (R402.1.2) AND AMENDED CODES
ROOF JOIST CAVITY = R-56 NON-VENTED (MIN. R-49)
EXTERIOR WALL INSULATION = R-22 (MIN. R-21)
BASEMENT WALL INSULATION = NA (MIN. R-19)
SLAB PERIMETER INSULATION = NA (MIN. R-10)
UNDER-SLAB INSULATION = NA (MIN. R-10)
GARAGE CEILING AND FLOOR SOFFITS= R-35 (MIN. R-30)
WINDOWS U-VALUE MAX. = U-.30 (MAX. U-.32)
INSULATION SUBCONTRACTOR MUST VERIFY THAT R-VALUES OF
PROPRIETARY PRODUCTS MEET OR EXCEED THE R-VALUES LISTED ABOVE
AND THAT INSTALLATION PERFORMED PER MANUFACTURER'S
SPECIFICATIONS. ALL INSULATION SHALL COMPLETELY FILL STUD/JOIST
SPACES AND HAVE PROPER AIR-BARRIER SHEATHING ON BOTH SIDES OF THE
STUD/JOIST SPACES.
GENERAL:
FOAM ALL WINDOWS, DOORS, PENETRATIONS, ELECTRICAL BOXES, HEADERS.
R-11 UNFACED FIBERGLASS BATTS AT 2X4 INTERIOR WALLS (SOUND)
R-19 UNFACED FIBERGLASS BATTS AT 2X6 INTERIOR WALLS (SOUND)
IRC 2015 AND IECC 2015 ENERGY EFFICIENCY
1" = 1'-0" 4
RAILING DETAIL
No. Description Date
DRB
APPROVED
3/31/2017
12:00:00 AM