Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB17-0095_Red Lion - Louver_1490627760.pdf
RusKIN® 3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816)761-7476 • FAX (816)765-8955 ELF6375DX and ELF6375DXH DRAINABLE STATIONARY LOUVERS EXTRUDED ALUMINUM LOUVER STANDARD CONSTRUCTION -1---„,_ FEATURES FRAME The ELF6375DX and ELF6375DXH offers: 6" (152) deep, 6063T5 extruded aluminum. IIIA' \ • 57%Free Area. ELF6375DX 1 — .081" (2.1) nominal wall thickness. ELF6375DXH—.125"(3.2)nomi I' • Published performance ratings based on nal wall thickness. Downspouts and caulk- testing in accordance with AMCA Publics ing surfaces provided. tion 511. BLADES B* • High performance frame system with drain- 6063T5 extruded aluminum. 111441able head collects and removes water to ELF6375DX — .081" (2.1) nominal wall provide excellent water penetration perfor- thickness. ELF6375DXH—.125"(3.2)nom- inal wall thickness. Drainable blades are 14111441 • Drain gutter in each blade minimizes water positioned at at 371/2° angle and spaced cascade between blades. approximately 529/32"(150)center to center. • Architecturally styled, hidden mullions allow- SCREEN ing continuous line appearance up to 120" 3/4 " x .051" (19 x 1.3) expanded, flattened I (3048).aluminumbirdscreen in removable frame. ,� I • Aluminum construction for low maintenance Screen adds approximately 1/2" (13) to lou- and high resistance to corrosion. ver depth. • All welded construction. FINISHA* r, Mill. VARIATIONS MINIMUM SIZEVariations to the basic design of these louvers 12"w x 12"h(305 x 305). are available at additional cost.They include: APPROXIMATE SHIPPING WEIGHT _ • Extended sill. ELF6375DX -4 lbs./ft.'(19.5 kg/m2) • Hinged frame. ELF6375DXH -6 lbs./ft.2(29.3kg/m2) "� •• Front or rear security bars. MAXIMUM FACTORY ASSEMBLY SIZE • Filter racks. Shall be 75 sq. ft. (7m2) per section, not to • A variety of bird and insect screens. exceed 120"w x 90"h(3048 x 2286)or 90"w • Selection of finishes: prime coat, baked Bird x 120"h(2286 x 3048). enamel (modified fluoro of mer), epoxy, Y, Louvers larger than the maximum factory Screen Acrodize, Kynar, clear and color anodize. assembly size will require field assembly of i, (Some variation in anodize color consistency smaller sections. is possible.) SUPPORTS Consult Ruskin for other special requirements. Louvers may be provided with rear mounted FRAME CONSTRUCTION blade supports that increase overall louver depth depending on louver size, assembly configuration or windload. 11/2"(38) I s i 1 1"(25) Consult Ruskin for additional information. -rVaries A* B* �, ll (152) STANDARD INTEGRAL FLANGE Dimensions in inches,parenthesis( )indicate millimeters. *Units furnished 1/a"(6)smaller than given opening dimensions. SIZE TAG QTY. FRAME VARIATIONS A*-WIDE B*-HIGH PROJECT LOCATION ARCH./ENGR. CONTRACTOR REPRESENTATIVE DATE Spec ELF6375DX/ELF6375DXH-597/Replaces ELF6375DX-296 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. ©Ruskin Manufacturing 1997 SUGGESTED SPECIFICATION Furnish and install louvers as hereinafter specified where shown on Louvers shall be Ruskin Model ELF6375DX or ELF6375DXH plans or as described in schedules. Louvers shall be stationary extruded 6063T5 aluminum construction as follows: drainable type with drain gutters in each blade and downspouts in Frame: 6" (152)deep. ELF6375DX -.081"(2.1)nominal wall jambs and mullions. Louvers shall have a minimum of 57% free thickness. ELF6375DXH - .125" (3.2) nominal wall area based on a 48"wide x 48"high(1219 x 1219)size.Stationary thickness. drainable blades shall be contained within a 6"(152)frame. Louver components (heads,jambs, sills, blades, & mullions) shall be fac- tory assembled by the louver manufacturer. Louver sizes too large ELF6375DXH 125" (3.2) nominal wall thickness. for shipping shall be built up by the contractor from factory assem Drainable blades are positioned at 371/2° angle and bled louver sections to provide overall sizes required. Louver spaced approximately 529/32 (150)center to center. design shall limit span between visible mullions to 10 feet (3) and Screen: 3/4"x.051"(19 x 1.3)expanded,flattened aluminum in shall incorporate structural supports required to withstand a wind- removable frame. load of 20 lbs. per sq. ft. (.96kPa) (equivalent of a 90 mph wind Finish: Select finish specification from Ruskin Finishes [145 KPH]wind—specifier may substitute any loading required). Brochure. Published louver performance data bearing the AMCA Certified Ratings Seal for Air Performance&Water Penetration must be sub- mitted for approval prior to fabrication and must demonstrate pres- sure drop and water penetration equal to or less than the Ruskin model specified. PERFORMANCE DATA AMCA Standard 500 provides a reasonable basis for testing and The louver system should be designed with a reasonable safety rating louvers. Testing to AMCA 500 is performed under a certain factor for louver performance. To ensure protection from water set of laboratory conditions. This does not guarantee that other carryover, design with a performance level somewhat below maxi- conditions will not occur in the actual environment where louvers mum desired pressure drop and.01 oz./sq.ft.of water penetration. must operate. WATER PENETRATION Test size 48" wide x 48" high (1219 x 1219) Beginning point of water penetration at .01 oz./sq. ft. is 1023 fpm (312 m/min). 0.3 (3.23) 0.25 i (2.69) d a' L L o 0.2 (2.15) 173 ,o o L N d N w0.15 U (1.61) C = E 73 u7 C 0.1 $ (1.08) • L b+ cts N Q 0.05 (.54) • 0 900 1000 1100 1200 1300 1400 (274) (305) (335) (366) (396) (427) Free Area Velocity in feet and (meters) per minute Standard air .075 lb/ft3 FREE AREA GUIDE Free Area Guide shows free area in ft2 and m2 for various sizes of ELF6375DX and ELF6375DXH. Width-Inches and Meters 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 102 108 114 120 0.30 0.46 0.61 0.76 0.91 1.07 1.22 1.37 1.52 1.68 1.83 1.98 2.13 2.29 2.44 2.59 2.74 2.90 3.05 12 0.31 0.49 0.67 0.86 1.04 1.22 1.41 1.59 1.77 1.96 2.14 2.32 2.51 2.69 2.88 3.06 3.25 3.43 3.61 0.30 0.03 0.05 0.06 0.08 0.10 0.11 0.13 0.15 0.16 0.18 0.20 0.22 0.23 0.25 0.27 0.28 0.30 0.32 0.34 18 0.58 0.93 1.28 1.63 1.98 2.32 2.68 3.03 3.37 3.73 4.08 4.42 4.77 5.13 5.48 5.82 6.18 6.52 6.87 0.46 0.05 0.09 0.12 0.15 0.18 0.22 0.25 0.28 0.31 0.35 0.38 0.41 0.44 0.48 0.51 0.54 0.57 0.61 0.64 24 0.86 1.38 1.89 2.40 2.92 3.43 3.96 4.47 4.98 5.50 6.02 6.53 7.05 7.57 8.09 8.60 9.12 9.63 10.15 0.61 0.08 0.13 0.18 0.22 0.27 0.32 0.37 0.42 0.46 0.51 0.56 0.61 0.66 0.70 0.75 0.80 0.85 0.89 0.94 m 30 1.14 1.82 2.50 3.18 3.87 4.54 5.24 5.92 6.59 7.28 7.97 8.64 9.33 10.01 10.70 11.37 12.06 12.74 13.42 a> 0.76 0.11 0.17 0.23 0.30 0.36 0.42 0.49 0.55 0.61 0.68 0.74 0.80 0.87 0.93 0.99 1.06 1.12 1.18 1.25 2 36 1.41 2.26 3.11 3.95 4.80 5.64 6.52 7.35 8.18 9.04 9.89 10.73 11.58 12.44 13.29 14.13 14.98 15.82 16.67 C 0.91 0.13 0.21 0.29 0.37 0.45 0.52 0.61 0.68 0.76 0.84 0.92 1.00 1.08 1.16 1.24 1.31 1.39 1.47 1.55 co 42 1.69 2.70 3.72 4.72 5.75 6.74 7.79 8.79 9.79 10.81 11.83 12.83 13.86 14.88 15.89 16.90 17.92 18.92 19.94 y 1.07 0.16 0.25 0.35 0.44 0.53 0.63 0.72 0.82 0.91 1.00 1.10 1.19 1.29 1.38 1.48 1.57 1.67 1.76 1.85 c 48 1.97 3.15 4.33 5.50 6.69 7.86 9.08 10.24 11.40 12.59 13.78 14.95 16.14 17.33 18.51 19.68 20.87 22.04 23.23 c 1.22 0.18 0.29 0.40 0.51 0.62 0.73 0.84 0.95 1.06 1.17 1.28 1.39 1.50 1.61 1.72 1.83 1.94 2.05 2.16 I 54 2.24 3.59 4.94 6.27 7.63 8.96 10.35 11.67 13.00 14.35 15.71 17.04 18.40 19.75 21.10 22.44 23.79 25.12 26.48 t 1.37 0.21 0.33 0.46 0.58 0.71 0.83 0.96 1.08 1.21 1.33 1.46 1.58 1.71 1.84 1.96 2.09 2.21 2.33 2.46 CA 60 2.52 4.03 5.55 7.05 8.57 10.06 11.62 13.12 14.60 16.13 17.65 19.14 20.67 22.19 23.71 25.21 26.73 28.22 29.75 2 1.52 0.23 0.37 0.52 0.66 0.80 0.93 1.08 1.22 1.36 1.50 1.64 1.78 1.92 2.06 2.20 2.34 2.48 2.62 2.76 66 2.80 4.47 6.16 7.82 9.51 11.17 12.90 14.56 16.20 17.90 19.59 21.24 22.94 24.63 26.31 27.98 29.67 31.32 33.01 1.68 0.26 0.42 0.57 0.73 0.88 1.04 1.20 1.35 1.51 1.66 1.82 1.97 2.13 2.29 2.44 2.60 2.76 2.91 3.07 72 3.08 4.92 6.76 8.59 10.45 12.27 14.18 16.00 17.81 19.67 21.53 23.35 25.21 27.07 28.91 30.74 32.60 34.42 36.28 1.83 0.29 0.46 0.63 0.80 0.97 1.14 1.32 1.49 1.66 1.83 2.00 2.17 2.34 2.52 2.69 2.86 3.03 3.20 3.37 78 3.35 5.36 7.37 9.37 11.40 13.38 15.45 17.44 19.41 21.44 23.47 25.45 27.48 29.51 31.52 33.51 35.54 37.52 39.55 1.98 0.31 0.50 0.68 0.87 1.06 1.24 1.44 10.91 1.80 1.99 2.18 2.37 2.55 2.74 2.93 3.11 3.30 3.49 3.68 84 3.63 5.80 7.98 10.14 12.34 14.48 16.73 18.88 21.02 23.21 25.41 27.55 29.75 31.94 34.12 36.28 38.48 40.62 42.82 2.13 0.34 0.54 0.74 0.94 1.15 1.35 1.00 1.75 1.95 2.16 2.36 2.56 2.76 2.97 3.17 3.37 3.58 3.77 3.98 90 3.91 6.25 8.59 10.92 13.28 15.59 18.01 20.32 22.62 24.98 27.35 29.65 32.02 34.38 36.73 39.05 41.41 43.72 46.09 2.29 0.36 0.58 0.80 1.01 1.23 1.45 1.67 1.89 2.10 2.32 2.54 2.76 2.98 3.19 3.41 3.63 3.85 4.06 4.28 PRESSURE DROP 1..00 (25.40) • Ratings do not include the effect of .80 (20.32) ;; a bird screen. .70 (17.78) .60(15.24) E .50(12.70) amCa AO)10.16) CERTIFIED RATIOGS C .30(7.62) INTAKE MODE WATER EXHAUST MODE 3 .20(5.08) ' AIRo y RIR t EIIOUERIEno ✓ Rno COMM RSSOCIRIIOR.IRC. c .10(2.54) .09(2.29) .08(2.03) Ruskin Manufacturing Company certifies • .07(1.78) that the ELF6375DX and ELF6375DXH d .06(1.52) / Louvers shown herein is licensed to bear • .05(1.27) the AMCA Seal. The ratings shown are y (1.02) based on tests and procedures per- .04 formed in accordance with AMCA a 03(.76) Publication 511 and comply with the requirements of the AMCA Certified .02(.51) Ratings Program. The AMCA Certified (7) , Ratings Seal applies to air performance ratings and water penetration ratings only. .01(.25) N M V V N V V 47 V W V N .1J W M M V CO 7 V 1� O O 0 0 0 0 0 0 O O O O O O O O r N M N t0 1, ODA O N V 1p 1 W O Air Velocity in feet and(meters)per minute through Free Area TYPICAL INSTALLATION DETAILS Masonry Metal Panel Wall Wall Metal :;:♦ ;;:� • ' ♦ .. '. �. Panel :40�� F• .,•�• CMU Insulatio .�•�• 1 6.4•• I , r-- Drip •i 111, Cap pi Louver Louver 1.IL I.,.iiillilliExtended k:t; f Sill -•�•4 Extended ;' ' a• i • �•�• Sill . .-.'..: -���� Wood Flange Installation Mount 1 •,. . 'tIIIIIIIIIIIII'- CMU � `1 ' r- Integral Flange Frame r I ll I Louver Louver IPI I I f 1 1 .4011110I ®► .......... 4 Sheating li Fastener .' 'Siding (by others) Accessories at additional cost. 3900 Dr.Greaves Rd. RusiaN® (Kansas FAX(816 30 )765 8955