DRB17-0095_Red Lion- Master Bedroom Fireplace vent_1490627760.PDF
INSTALLER: Leave this manual with the appliance. CONSUMER:Retain this manual for future reference. These instructions are supplementary to the Installation TOWN & C O U N T R Y and Operating Instructions supplied with the fireplace > LUXURY FIREPLACES and should be kept together. Refer to the Installation .'. and Operating Instructions for proper gas supply, safety OPTIONAL .-: requirements and operating instructions. HORIZONTAL VARIABLE DEPTH POWER VENT KIT r w 44 . For use with any TC Series «C„&<<p„unit, except TC 54 models TCVT.PV1.25 1 - 25 FEET TCVT.PV7.110 7 - 110 FEET We endorse NFl NATIONAL (11:4) FIREPLACE INSTALLATION AND C U5 INSTITUTE OPERATING INSTRUCTIONS 130715-20 TCVT.PV-D 5056.425111 D Power Vent Installation PAINT: The vent terminal comes pre-painted Locate the fireplace as per the main instructions supplied. with Thurmalox 230 Series paint by Make the following modifications to add the components used with the Flush Dampney Co.,but can be painted Mount Power Vent Kits. This installation must conform with local codes or, in the to match your wall finish color absence of local codes,with the National Fuel Gas Code,ANSI Z223.1/NFPA 54,or using high temperature paint that the Natural Gas and Propane Installation Code,CSA B149.1. can withstand temperatures of at least 250 degrees Fahrenheit or 120 All electrical installations should be performed by a qualified electrician to the degrees Celcius. Canadian and U.S.National Electrical Codes(CSA C22.1 for Canada), (ANSI/NFPA 70 for the U.S.)and/or local electrical codes. Ensure that your paint is compatible with Thurmalox 230 Series paint. UNDER NO CIRCUMSTANCES SHALL A RHEOSTAT BE USED TO ALTER THE VOLTAGE SUPPLY TO THIS UNIT. MINIMUM CLEARANCES TO COMBUSTIBLE Contents of Power Vent Kit Terminal casing: Din.(0mm) ITEM PART No. DESCRIPTION QTY Vertical vent pipe: 1 TCVT.7894 Power Vent Assy. 1 1.5 in.(38mm) 2 8020.5 Inner wall Plate 1 Horizontal vent pipe: 3 8029 Wall Pipe Cover 1 1.5 in.(38mm) 4 TCVT.80285WLD Wall Sleeve Assembly 1 All other clearances are as per the fireplace 5 TCVT.PVCINST Instructions 1 installation instructions. This powervent is switchable from - "Low"to"High'.'The power setting must ' . - .. - be selected prior to operation. TCVT.PV1.25 I �, "Low" = 0 - 6 FEET r -_ - "Highi"= 7 - 25 FEET ` ' I , , . ". TCVT.PV7.110 _�' "Low"= 7 - 25 FEET ., , ,2'.! w "High"= 26 110 FEET • Jr. Follow the selection chart on page 3 to . ". .-- select which powervent kit to order. - ° i ` t TOWN&C0UNTav 130715 20 TCVT.PV-D LUXURY FIREPLACES 5056.425111-D 2 Venting Length POWER VENT 0-6' 7'-25' 26'-110' TCVT.PV1.25 LOW HIGH - TCVT.PV7.110 - LOW HIGH Powervents Available by Model MODEL TCVT.PV1.25 TCVT.PV7.110 TCVT.PVKIT REQUIRED TC30.D J J YES TC36.DAR J J YES TC36.D J J YES TC36.DST J J YES TCWS.38D J J YES TC42.D J J YES TCWS.54D J J YES TCWS.54DST J J NO Power Vent Fig.#1 VENTING CONFIGURATIONS minimum 1W clearance n < chimney See table(pg.3) to combustable surfaces < power vent to determine which Maximum total vent length is from vent pipe _ powervent kit to use. 110ft plus six 90-degree elbows or combination of other elbows equaling 90-degrees, with a maximum 66 foot vertical rise. Minimum total vent length is 3 ft minimum venting-3' plus one 90-degree elbow. 66'maximum The vent can be installed with = I vertical rise plus one 90 degree elbow any combination of rise and run I including up to 3 ft below the A I unit. Ensure vent pipe is properly ® IJ 66'maximum R vertical rise �1 �� supported. \ I•-nt terminal 110'maximum 1 a_ vent length Maximum Combined _,;• using power vent vertical&horizontal venting- mI 4 110 ft plus six 90 degree elbows. maximum 3'below unit_ to center of vent pipe — power vent (-\__) 130715-20-TCVT.PV-D 5056.425111-D TowNacouNTRvr 3 Minimum Vent Length Chart Fig.#2 A B C Minimum Rise Pipe Min. From Floor to Flue Center Length Pipe Length . .: . _I-7 } 6 TCWS54D**TCWS38D TC3OD TC36D* TC 42D TC36DST A 1 49" 45" 47 51" 57" 56" 0" 3 feet �.�—rtt61" 57" 59" 63" 69" 68" 12" 2 feet 7-1.—=-11.1 73" 69" 71" 75" 81" 80" 24" 1 foot • *TC36D and TC36DAR have same dimensions. E `�' *`TOWS 54D, and TOWS 54DST have the same dimensions This power vent kit cannot be used on model TC54.D Vent Terminal Minimum Clearances Fig.#3 INSIDECAG j C ETAILR j ©.L� �I I— riiiiii, T FIXED �,��� �] / gm._ I �I j CLOSED OPEN- FIXED �t - , ABLE CLOSED f�� I ,1.,0 D ��% M `4•••IIT +V A j f C�K f ❑V VENT TERMINAL O AIR SUPPLY INLET V� SREA WHERE PERMITTED INAL © GAS METER NOA= clearances above grade,veranda,porch,deck,or balcony[* H= *not to be installed above a meter/regulator assembly within 12 inches(30 cm)minimum] 3 feet(90 cm)horizontally from the center-line of the regula- B= clearance to window or door that may be opened[*12 tor inches(30 cm)minimum] 1= clearance to service regulator vent outlet[*6 feet(1.8 m) C= clearance to permanently closed window[minimum 12 minimum] inches(30 cm)recommended to prevent condensation on J= clearance to nonmechanical air supply inlet to building or the window] combustion air inlet to any other appliance[*12 inches(30 D= vertical clearance to ventilated soffit located above the ter- cm)minimum] mina)within a horizontal distance of 2 feet(60 cm)from the K= clearance to a mechanical air supply inlet[*6 feet(1.8 m) edge of the terminal[0 inches(0 cm)minimum] minimum] E= clearance to unventilated soffit[0 inches(0 cm)minimum] L= A clearance above paved side-walk or a paved driveway F= clearance to outside corner[6 inches(15 cm)minimum] located on public property[*7 feet(2.1 m)minimum] G= clearance to inside corner[3 inches(7.5 cm)minimum] M= clearance under veranda,porch,deck,or balcony [0 inches(0 cm)minimum**] A a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** only permitted if veranda,porch,deck,or balcony is fully open on a minimum of 2 sides beneath the floor* * as specified in CGA B149 Installation Codes, Note:local Codes or Regulation may require different clearances * for U.S.A.Installations follow the current National Fuel Gas Code,ANSI Z223.1 eTOWN&COUNTRY 130715-20-TCVT.PV-D LUXURY,,,E, E 5056.425111 D 4 Horizontal (Side Wall) Venting This kit uses either Simpson Duravent GS direct vent pipe,Secure Vent direct vent pipe,Selkirk Direct-temp vent pipe or ICC Exceldirect vent pipe with a 5"inner pipe and an 8"outer pipe. For part numbers see the table of venting components on page 12 of this manual.This vent can only be used as a side wall termination. 1. Attach the vent adaptor directly to the appliance with the three screws and seal outer CAUTION: pipe with aluminium tape provided.(Fig.#4) This terminal is designed to be flush, Note:The inner pipe does not need to be sealed. or protruding to the finished outside wall. Under no circumstances 2. Connect one of the high temperature silicone tubes to the upper pressure tap (marked should this terminal be recessed "LOW") on the adaptor.(Fig.#4) Secure with the hose clamp provided and route the tube into the wall past this point. through any hole back to the control box.This tube will be connected to the "low"side of (Fig.#8) the pressure switch inside the control compartment.(Fig.#20) Connect the second tube to the lower pressure tap(marked"HIGH")and route to the control box as before.Connect this tube to the remaining port on the pressure switch. Tubes may touch unit and be trimmed if required. Note: Ensure that there are no blockages in these tubes,as this will cause the control to malfunction. Fig.#4 Power Vent Adaptor. Part#5096.816 UPPER PRESSURE SECURE WITH MUST BE INSTALLED TAP, MARKED THREE SCREWS AT THE UNIT. woo,. "LOW'% AND SEAL WITH � TAPE. 'u' CAUTION: The adjustable vent restrictor located \i on the underside of the firebox top \ O must be fully open. LOWER PRESSURE TAP, MARKED "HIGH" /41)4 3.Locate the power vent termination following the clearance to combustible table (Page 2),venting configuration diagram (Fig.#1 &2), and terminal location diagram (Fig.#3). 4.Cut and frame a 14 5/8"wide by 14 7/8"high opening.For standard up and out installations,the opening should be 3/4"lower than the minimum specified in Fig.#2. Height of the opening will vary with each installation.See Fig.#5. 5.Attach the power vent terminal, by securing the outer flanges on the perimeter of the NOTE: terminal to the outside wall;ensure that the terminal is the right way up (exhaust at the THE TCWS 54DST DOES NOT bottom).Once secured to the building,the outer flanges may be covered with siding/ REQUIRE THE TCVT.PVKIT. stucco/etc.up to the level of the perimeter edge.As per local building codes.See Fig.#6. IT HAS A VACUUM SWITCH AND 6.Determine desired amount of exterior power vent protrusion, and fasten mounting TUBES WHICH ARE PRE- flange with supplied fasteners.Silicone joint after installation.See Fig.#8 and#13. INSTALLED INTO THE UNIT. 7.For wall thicknesses 7 1/2"or less, install the inner wall plate supplied over the terminal as shown in Fig.#7 and secure to the framing. 130715-20-TCVT.PV-D 5056.425111-D T 5 Fig. #5 CAUTION: The rise and run combination and the number of elbows must not exceed specifications in Fig#1 and Fig#2. Fig.#7 LJ. ALL PLATE T 14 7/8" 7 7/8" SEAL WITH SILICONE 4144 /5 8—. ON ALL FOUR SIDES '1 NOTCH AT THE TOP Fig.#6 TERMINAL SECURING FLANGE SILICONE AFTER \ ` INSTALLATION WALL FINISH NO �I DEEPER THAN 1 1/4" 0 EXHAUST r I. ADJUSTABLE FROM FLUSH TO SURFACE. MOUNT IN 1 1/2" INCREMENTS TOWN&COUNTRY 130715-20-TCVT.PV-D u..,.,,...L..EL 5056.425111-D 6 7. For wall thicknesses greater than 7 1/2"and up to a maximum of ig.#11 16 1/2;attach the inner wall plate to the wall sleeve assembly, using the four screws provided (Fig #9).Then slide this assembly over the terminal with the notch at the top (Fig#11 & Fig.#12). 8.Slide the wall pipe cover, with the small notch oriented at the top, NOTCH AT over the vent pipe and attach pipe to the fireplace.(Fig#10)Connect THE TOP the vent pipe to the vent terminal and then secure the inner wall plate and wall pipe cover to the framing.This ensures that any insulation is retained in the wall and that the correct clearances are maintained. I.:0 "--0.-.- 400 9.Run the required Simpson Duravent GS/Secure Vent/Selkirk A j41) Direct-temp or ICC Exceldirect pipe from the adaptor to the terminal assembly.Assemble as per the vent pipe manufacturer's instructions including all shields and firestops. 111111 II VII NOTE: The vent terminal comes pre-painted, but can be painted to match your wall finish color using high temperature paint that can withstand temperatures of at least 250 degrees Fahrenheit or 120 degrees Celcius. Fig.#9 Fig.#12 WALL THICKNESS GREATER THAN INNER WALL PLATE 7 1/2" UP TO MAX. 16 1/2" ..,___ . 1014111 INNER WALL PLATE . . 14' . 1 WALL SLEEVE WALL PIPEVER ASSEMBLY • C� ATTACH SCREWS FROM THE INSIDE WALL SLEEVE ASSEMBLY Fig.#10 i Fig.#13 SILICONE GAP WALL PIPE COVER d ON ALL SIDES 1f .9" AFTER .` INSTALLATION A .1_17 ._..., NOTCH AT TOP 11 O. ,I\ kiik,:j0 -11 ,14 ] \ 1 — 130715-20-TCVT.PV-D 5056.425111-D TowNacouNTR: r 7 Control System Connection Fig.# ACCESS PANEL 90 X . For "Series C" Fireplaces . r i .. The gas control system is located on the right hand side of the ' firebox behind an access panel and the decorative panel. 1. Burner assembly, burner media and/or decorative panels may need to be removed if already installed (see main • installation manual for details). - f 2. Remove access panel located on the right hand side of the x r firebox(Fig.#14). - *�'_ . . 3. Locate and disconnect the spade connectors in the black Fig.#15 , opirriRir 1 piciik No:wire loop on the right side of the module and in the orange wire running from the module to the socket labelled"pilot" IP _ •..° on the valve (Fig.# 15 and#16). A \ , 01 4. Using the jumper wires provided,connect the 120V"hot" ,e---- supply wire to one of the black wires from the control module. • r.� • 'AlThen connect the"hot"wire from the power vent blower to the other black wire on the control module, (Fig.#17).The ' module acts as a switch to turn on the power vent blower. (Also see wiring diagram on Pg.15). - S"AD ®®NNECTORS[IM BAt ' WIRE LOOP Fig.#16 , I� �� j {. 7--- .,,........060:r r ORANGEWM FROM MODULE TO WALVE HOT WIRE FROM Fig.#17 SUPPLIED WIRES TO CONNECT J�0 BLOWER BLACK WIRE to`I MODULE . HOT WIRE FROM 120V SUPPLY I 1 - - 1111 - Ili 111111W4 -- . , ...... .11"6 arAh.... 1 , a .., s ___,:,... . , ..,„,. II TOWN&COUNTRY 130715 20 TCVT.PV D LUXURY,,,E, E 5056.425111 D 8 Pressure Switch Installation Fig #19 r* 1 _ For "Series C" Fireplaces PRESSURES ' 1. Connect the pressure switch jumper wires to the orange ‘11'` • wire(Fig.# 19). s, 2. Attach the silicone tube from the upper pressure tap on the ' ORANGE WIRE power vent adaptor(Fig.#4)to the"low"port of the pressure switch.Attach the other silicone tube from the lower pressure \� tap to the"high"port of the pressure switch (Fig.#20). iy 3. Secure the pressure switch in the control box using the . 4 , a +f f5 screw provided (Fig.#21). 4. Continue with installation and reassemble all of the parts ( # y,A previously removed. Fig.#20 r. . This power vent system can only run on 115 V AC. Before operating the unit, the battery backup located behind the wall switch receiver must be removed.The wall switch must be set to power vent mode,see unit manual. w HIGH SIDE OF SWITCH WARNING:This switch must be installed in a vertical position and will not function if installed otherwise.(Fig. 18) LOW SIDE ` ' IR' F SWITCH • Fig.#18 Fig.#21 s NI La rof • _ ) \\17 io., r. 1. 130715-20-TCVT.PV-D 5056.425111-D TOWN&rOU!\1-m 9 Control System Connection For "Series D" Fireplaces FIREBOX ACCESS PANEL The gas control system is located on the right hand side of the firebox behind an access panel and the decorative firebox panel (if installed).The fireplace is operated via a wall Fig.#22 control and a hand held remote control unit. The wall control is connected to the fireplace by a 40 ft.communication cable supplied with the fireplace. n R y • Installation r. rr 1. Place the fireplace in the desired location. . 2. Remove the window from the fireplace. - 3. Remove access panel from right hand side of the firebox(Fig#22). JUNCTION BOX 4. Connect 110 V.AC electrical supply to the wires installed inside the junction box (Fig#23).The fireplace is rated at 110 volts, 60Hz, 0.25A.The optional power vent kit Fig.#23 / is rated at 115 volts, 60Hz, 1.8A. The electrical wires can be accessed from both inside and outside the junction box by • removing one of the two small access panels (Figs#23&24). 5. Connect the gas supply to the valve(Fig#24). new 6. Attach one end of the wall switch control cable to the wall control.(not shown), and the other end to the interface board OUTER ACCESS PANEL (Fig#24). 7. If not already installed, install the burner using the instructions supplied with the burner kit. VACUUM TRANSFORMER REGULATOR SWITCH BOARD 8. Turn on the gas supply and check that all connections are tight and leak free. Fig.#24 INSIDE ACCESS PANEL -tow, .�, weanl C POWER ', T -y�►• � _ VENT 7. SWITCH A ,..+ JUNCTION BOX GAS CONNECTOR WALL SWITCH MODULE CONNECTOR INTERFACE BOARD TOWN&COUNTRY 130715-20-TCVT.PV-D _ „,,c,,,c cE= 5056.425111-D 10 Pressure Switch Installation For "Series D" Fireplaces Attach the silicone tube from the upper pressure tap on the power vent adaptor (Fig.#4)to the"low"port of the pressure switch.Attach the other silicone tube from the lower pressure ap to the"high"port of the pressure switch (Fig.#25). Fig.#25 641111111 4 HIGH SIDE .{ OF SWITCH 'rs LOWSIDE / OF SWITCH f . . l/ Selecting Natural Vent and Power Vent Modes Important Note: The NV/PV(Natural Vent/Power Vent) Fig.#26 p switch (Fig#26)on the interface board ,MP ' '4 (Fig#24) is set according to which type ofI-- ' . �- y When switching between NV evacuating vent system is present. If the 0 and PV, both the electrical fireplace is vented without the assistance - power supply to the fireplace of a power vent, the switch should be set p to"NV"If using a power vent, `PV"should - . .. ;� must be turned off and the be selected. :=1 , ' '� backup batteries removed to ,i properly re-set the module. 130715-20-TCVT.PV-D 5056.425111-D TOWN& OUNTR' V 11 Fan Wiring Fig.#29 • - The Flush Mount Power Vent assembly has an electrical connector block mounted internally.The external wiring from the main voltage/control module should be connected to this block.Follow the steps below to access this block. I • • 1. Remove the 2 top and 2 bottom screws securing the end0 cap only. Remove the cover(Fig#27). 2. Remove the 4 screws securing the blower cover to the assembly and remove.(Fig#29) • • 3. Run the power supply wire from the fireplace to the connector block inside the power vent assembly. • (Fig#30).Connect wires as shown.Connect ground to ground screw and tighten strain relief. Fig.#30 4. Reposition blower cover and secure in place with previously removed screws. Place the end cover back onto the upper tabs MD and secure in place with 2 screws on top and 2 on bottom. . . WT/ .- 4 DK R 1 .BK Fig.#27 Y+f 7 SCREWS 111111111A 11 • : , 1 - 7 .._... • _,....i..it...- Fig.#31 N H G . _ . . COMBUSTION BLOWER co G) 2 D m I m z I Fig.#28 K.__), TERMINAL 0 0 0 2 BLOCK 0 0 0 = m W Wco GREY n D BLACK W 0 _ D 3 pooklmluirrAmmail RED D D m o 1 - —rf SPEED SELECTOR SWITCH SCREWS POWER VENT WIRING DIAGRAM . 1 TOWN&COUNTRY 130715 20 TCVT.PV D o.u, ,,,E, E 5056.425111-D 12 Dimensions 151/2" 1 5/8" •� 611/16" 16 7/8" . ' 3 J7 7/8" L o i- • • -i o .— s o s 1-9 11/16" 16 3/4" NOTE:If this powervent is to be installed in aTC30 NOTE:For all other units use the restrictor then it should use the full restrictor as shown in shown in Fig.#33. Fig.#32. Fig.#32 Fig.#33 - • ` s • 710 .4,-.7. •710- , IP („fsst:(::s4mmf- ' ) ,. 11111111111111\N :.-I' 1 -I '11 I 1.0):\.-'-- , , _ . . . • \ la . Ns.si,..._ IL , __ _,_ . ..___ , ....... _ 130715-20-TCVT.PV-D 5056.425111-D TOWN& OUNTRY�r 13 Venting Components SIMPSON DURAVENT COMPONENTS SECURE VENT COMPONENTS Number Description Number Description 1208 6"Pipe Length SV5L6 6"Pipe Length 1207 9"Pipe Length SV5L12 12"Pipe Length 1206 12"Pipe Length SV5L24 24"Pipe Length 1204 24"Pipe Length SV5L36 36"Pipe Length 1203 36"Pipe Length SV5L48 48"Pipe Length 1202 48"Pipe Length SV5LA 6"Pipe,Adjustable 1211 11"to 14-5/8"Pipe,Adjustable SV5LA12 12"Pipe,Adjustable 1217 4-10"Pipe,Adjustable SV5LA24 24"Pipe,Adjustable 1245 45° Elbow SV5E45 Swivel 45° Elbow 1290 90° Elbow SV5E90 Swivel 90° Elbow 1240 Round Ceiling Support/Wall Thimble Cover SV5CSB Adjustable decorative sq.cathedral support 1241 Cathedral Ceiling Support Box SV5AC Collar for decorative sq.cathedral support 1242 Wall Firestop SV5SU Universal support 1247 Wall Thimble SV5SD Floor support 1263 Ceiling Firestop SV5BM Wall band 1288 Wall Strap SV5RSA Attic radiation shield SV5RSM Wall radiation shield SV5BF Firestop ICC MODEL EXCELDIRECT SELKIRK DIRECT-TEMP Number Description Number Description TC-5DL6 6"Pipe Length 1605006 6"Pipe Length TC-5DL1 12"Pipe Length 1605009 9"Pipe Length TC-5DL2 24"Pipe Length 1605012 12"Pipe Length TC-5DL4 48"Pipe Length 1605018 18"Pipe Length TC-5DLF 36"Flexible Length 1605024 24"Pipe Length TC-5DLT 12"Pipe,Adjustable, Galvalume 1605036 36"Pipe Length TE-5DE45 Swivel 45° Elbow, Galvalume 1605048 48"Pipe Length TE-5DE90 Swivel 90° Elbow, Galvalume 1605082 4-10"Pipe,Adjustable TM-5SS Square Support/Radiation Shield 1605215 45° Elbow TM-5RDS Round Support/Radiation Shield 1605230 90° Elbow TM-5CS Cieling Support/Firestop 1605424B Cathedral ceiling support box(blk) TM-OS Offset Support 1605500 Firestop spacer TM SR Roof Support 1605460B Wall thimble (blk) TM-WS Adjustable Wall Support 1605430 Wall support band TM-5WT Insulated Wall Thimble TM-5TR Trim Ring, Black TM-5AS Attic Radiation Shield/Firestop TOWN&COUNTRY 130715-20-TCVT.PV-D c. „,,c,cc.cE= 5056.425111-D 14 Wiring Diagram for Series "C" Fireplaces Fig.#34 �, Y 2 a3 m 3 r c y P2o .3 E _y%u 0 E c °' 2 U It — — a) N 31oe18 J I > Ts �I— � — — — I aa) I •°- L Ill !0 o z — I @ IIa® . :] • I 6 ILP0ol!0 reie o I � � c I 0 I I� I a 0 0 � � co — I = •L o6 I - - - v 2 -,!-,§13bio V as V 11 r — — L 3 0 yr y--� C rte+ L m o .O III w 0c 1:1-1:1C C (6CS 73 III E E d � vi U 7 ._'--U �U V o III a) s III m L Q Y Y O a--, U U I6 6 Y WI I I o � + CO M a ca. s aoI I I U [ o n � Z 0_ 0 Z I I I Q ® � It LI To Qw ce, III O zw � cr a 2 m 0 g Y , .oU Q m e S 1E 2 s 2 m 7 O uiOl I I c7 c7.)Ci) oom _ CC m 0 .- a--, N N 2 "I LL o y T a 3 01 I n e6ue.i0 s a c c� I I I ar — — (M-0—10– ❑ ° a o — 0U) JI I asue�0 ��� ❑ d o as v C � III L a All III - O unIur`�r�-1i,. V III I Liiii111 I ,�-� — I❑I L III h °' , ,� R w III 2 rz CO a co o ° u_ ., o +_ +E. a>vc a) O C c c > V) > > N a)\ o c CD Lt) \To / = < / U U 3 V / o) ocs L a$ a CL U 130715-20-TCVT.PV-D 5056.425111-D TOWN&COUNTRY e 15 Wiring Diagram for Series "D" Fireplaces Fig.#35 OPTIONAL HOME ® DIGITAL I/O FLAME ON/OFF I U• AUTOMATION SOLIDBRO SP I 1 DIGITAL I/O SPARE WHITE BROWN ® DIGITAL I/O LIGHTS ON/OFF SOLID GREEN COMMON ®■ L WHITE BLUE olma. ® SOLIDOBLUEOV FLAME LOW/HIGH 0 ■ ANALOG OIOV SPARE I J ®■ ANALOG 010V LIGHTS LOW I HIGH G. ®. SOLID ORANGE V ® (COMMON ; L WHITE ORANGE I N co z ONE I LIGHTS A co ✓ n LU 2' VAC z uJ W I- WALL SWITCH laAIR PRESSURE —1--111 a SWITCH u TRANS REGULATOR `GM • FORMER BOARD _ON I OFF REMOTE le - hVALVE SELECTOR n CAT 5 ETHERNET CABLE(SUPPLIED) — NATURAL POWER VENT VENT mi OPTIONAL ' POWER VENT I JUNCTION BOX 1----1 POWER 1MODULE VENT 1 I liyil 1 ' IT 110 VAC 60 Hz — NUETRAL I - 1 • GND I I • I VALVE CONTROL BOX el?, NaCOUNTRY 130715-20-TCVT.PV-D .W�a ,,,E,L. 5056.425111-D 16 Replacement Parts ITEM PART No. DESCRIPTION QTY 1 TCVT.7895 FLUSH MOUNT POWER VENT ASSY. 1 2 7895 BLOWER GRILL 1 3 8240 TUBE,5/16"OD,1/16"THICK 2 4 7895.5 GRILL COVER 1 5 8020.5 INNER WALL PLATE 1 6 5096.816 VENTING ADAPTER 1 *7 TCVT.9280 PRESSURE SWITCH ASSEMBLY 1 8 TCVT.507156C POWER VENT SWITCH WIRE 1 9 5068.8065 1/4"LDF PAPER GASKET 1 10 TCVT.7893 TCVTFMPV OUTER CASING ASSEMBLY 1 11 TCVT502464 BLOWER,POWERVENT 1 12 TCVT.80285WLD WALL SLEEVE ASSEMBLY 1 13 8029 WALL PIPE COVER 1 *NOT SHOWN Ep Fig.#36 0 II I 77-7"."--1 i 1 1 L i e 1111 •4 0 :1 f -' I 1, .I , . ri.. N . li 4 . .., ...„..„...,,, ,.., ,..._____,11 .„ .___..,.___,z____=__ O Oii . 7NN. y .., 0.1 ., 0 130715-20-TCVT.PV-D 5056.425111-D TOWN&COUNTRY V LUXURY FIREPLACES 17 eTOWN&COUNTRY 130715-20-TCVT.PV-D Lu.u,,,,,E,L.„, 5056.425111-D 18 130715-20-TCVT.PV-D 5056.425111-D TOWN&COUNTRY V 19 ©2015 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. 111111 TOWN & COUNTRY LUXURY FIREPLACES For Technical Support, please contact your retailer. www.townandcountryfireplaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada