Town of Vail
Design Review Board
Changesto approved plans
Re: Red Lion Condominium UnitsR-3
The following isa detailed description of changes being requested from the original
approval of Red Lion Condominium unit 304.
Thissubmittal includes six revisionsto the approved plans. Each of the revisions are
outlined below and have referencesto the updateson the floorplansand elevations.
Please contact Ben Marion (970)949-7034 benm@vagarchitects.com with any
questions, clarificationsor need for additional information. Changes have been
clouded in red on the drawing sheetswith notes. I have also included cut sheetsand
a photo of the tree to be removed .
Item 1 A mechanical air intake louverhasbeen added to the west façade of the
building. Ibis louver istwelve inchestall and twenty four inches long, the louver will be
painted to match the existing stucco. The louver can be found on plan sheet A2.1
nearthe intersection of grid lines6 and C. It suppliesfresh airto the Fan coil unit in
room 103 and supplies return air required by the range hood requirements in the
kitchen. The louver isalso shown on sheet A3.1 proposed West elevation to the top
right of window number2.
Item 2 A gasfireplace vent has been added to the West facade of the building. The
vent isfourteen inchestall and fourteen incheswide, the vent will be painted to match
the existing stucco. The vent can be found on sheet A2.1 nearthe intersection of grid
lines6 and G. This isa gasfireplace vent forthe unit in master bedroom 114. The vent is
also shown on sheet A3.1 proposed West elevation between windows 24 and 25.
Item 3 Windows59 and 60 on the North elevation of the building have been shortened
in height. The approved plansshow the windowsas2'-8" wide by 5'-0" tall. We would
like to change the windows to 2'-8" wide by 2'-8" tall. Please refer to sheet A3.2
Proposed North Elevation forthe new shortened windows. Also refer to sheet A9.1 for
the updated window schedule.
Physical Address: (970)949-7034 Mailing Address:
105 Edwards Village Blvd, P.O.Box 1734
Suite G104 Vail,CO 81658-1734
Edwards,CO 81632 email: general@vagarchitects.com
Item 4The location of the two condensing units hasbeen changed from the building
roof top to the area below the entry deck in the side alley. Originally the condensing
unitswe going to be placed on the roof near the ridgeline but after review of the site
the location underthe deck has been determined to be betterfor protection of the
units, sound buffering and they will now be hidden from view. Please referto sheet
A3.2 and sheet A2.
Item 5 Remove abandoned grease fan exhaust chimney from the roof. Originally this
grease fan and chimney were thought to be active and we to be extended up to the
new roof. It hasbeen determined that the duct and fan have been abandoned . The
duct will be removed so there will not be a need for the new chimney.
Item 6 Remove the spruce tree from planter between the Unit 3 entry and the entry to
Bridge Street Bar. This tree needsto be removed during construction to perform work
on the building foundation in that area. The tree looksto be old and sick and does not
look like it will live very long. The tree hasgrown between two entry roofsand isvery
close to the building which could be deemed a hazard . The HOA does not wish to
keep the tree after construction. The tree is in a small planter which would be better if
filled with flowers or small shrubs.
If we can provide any further information please let us know.
Sincerely,
Ben Marion
Project Manager
Benm®ragarchitects.com
www.vagarchitects.com
Judge
± ASSOCIATES .r,
ceiet raters[
ARCHITECTS + PLANNERS .
970.949.7034
PO Box 1734
Vail, CO 81658-1734
Encl.: Application Package and requested documentsto the DRB.
Physical Address: (970)949-7034 Mailing Address:
105 Edwards Village Blvd, P.O.Box 1734
Suite G104 Vail,CO 81658-1734
Edwards,CO 81632 email: general@vagarchitects.com