HomeMy WebLinkAboutDRB17-0132_L4 Details_1499364060.pdfStone veneer to match house stone
18"
Pond Level
90.6' 6"
91.1'
89.9'
88.0'
Rigid Insulation
4" Stone Veneer to Match
House Stone
4"
7'-0" Radius
3" thick Capstone with 1" reveal
and offset by 1" from concrete
shell to support the steel pan.
1"
1"
3/16" Steel Support Pan to support
the lava rock, logs, and burner
Burner
2" Lava Rock
Course
Ignition
Valve
GFI receptacle. Switch
power to receptacle to
control fire pit operation
Gas shut-off. Sleeve to outside of
structure. 3
4" rigid gas line to house.
Drainage from structure.
Slope concrete to drain,
daylight as required.
18 square inch opening
(both sides) for ventilation.
3" Colorado Buff Stone
Cap with 1" reveal
8" Poured in place Concrete Wall
Note:
See Structural Drawings for
reinforcement, depth of
footings, etc.
(typ.)
12"-16" Tread
4"
Colorado Buff Sandstone
patio stone on a concrete
slab with mortar joints.
6" thick Rose Sandstone steps
(see Plan for layout and depth).
Compact Subgrade to 95%
S.P.D. prior to placing
each successive step.
Filter Fabric
Compacted
Road Base
Landscape Boulders
(see Plan)
Provide pockets at steps for
plantings
9'-6"
overlap
Poured-in-place concrete wall
with waterproofing as required
(both sides)
Colorado Buff Sandstone
landings on sand setting
Slope to drain
Dry Well:
Provide a gravel well to absorb ground water as shown. Provide a
protection layer of filter fabric Mirafi 140-N or equivalent. (no fabric on the
bottom of the Well). Fill Well with 11
2" to 3" diameter clean rock (ASTM
D-448 or better). Do not damage filter fabric during installation of rock. In
bottom of well provide sump pump(s) as necessary to drain well. Verify
all drainage methods with Civil Engineer.
4'-0"
1'-6"
15'-3"
Filter Fabric
Trench Drain
Refer to Site Plan for layout
(see detail this sheet)
Steel Ledger
4" Fine Aggregate Base
to Protect Liner.
EPDM Pond Liner, Lap Joints Sealed in
the Field. Sand Cushion if Required
4-6" River Rock
Note: Flagstone Pavers to be
Colorado Buff Sandstone.
2"-3" Thick Sandstone Pavers,
Random Pattern 24" Min. Dia.
Sand Setting Bed.
Filter Fabric.
Aggregate Base as Required
by Soils Engineer.
Compacted Subgrade. (Compaction
per Soils Report.)
4"
internal
slope
4"-12"
12
" Expansion Joint with seal
Typical Plan Section of Grate
Cast Iron Sectional Grate
Polymer Concrete trench drain assembled in the field
per manufacturer's specifications
Compacted
Subgrade
4" concrete collar entire. See Structural
drawings for reinforcement
4" aggregate backfill
Adjacent Paving
Depth as Required
5
1
Random Boulder
(see Plan)
Compacted Subgrade:
Smooth Prepared Subgrade Free
of Sharp Stones.
Reinforced Slope as
Required
Turn back liner with
Class 6 Road Base
EPDM Pond Liner. Lap joints sealed
in field. Sand cushion if required
4" Fine Aggregate Base
to Protect Liner.
Pond Level
P.O. Box 1871 Avon
Colorado
81620
(970)
390-6550 ric@fieldscape.net
c
Issue Date
Sheet:
Of: four
L4
Pond
Layout
Plan
The Fagan
Residence
Lot 7, Second
Amendment to the Lia Zneimer
Subdivision,
Town of Vail,
Eagle
County,
Colorado
Copyright
Fieldscape Incorporated
All Rights Reserved
This document, and the ideas and
designs incorporated herein, as an
instrument of professional service, is
the property of Fieldscape
Incorporated and is not to be used,
in whole or in part, for any other
project without the written
authorization of Ric Fields
Owner Sept. 3, '16
Fire Pit Wall Detail
3/4"=1'-0"
401
Sandset Stone Walkway Detail
1"=1'-0"
402
Trench Drain Section
1"=1'-0"
403
Typical Pond Edge Detail
3/4"=1'-0"
404
T.O.V. Apr. 3, '17
DRB
APPROVED
7/5/2017 12:00:00
AM