Loading...
HomeMy WebLinkAboutDRB17-0132_L4 Details_1499364060.pdfStone veneer to match house stone 18" Pond Level 90.6' 6" 91.1' 89.9' 88.0' Rigid Insulation 4" Stone Veneer to Match House Stone 4" 7'-0" Radius 3" thick Capstone with 1" reveal and offset by 1" from concrete shell to support the steel pan. 1" 1" 3/16" Steel Support Pan to support the lava rock, logs, and burner Burner 2" Lava Rock Course Ignition Valve GFI receptacle. Switch power to receptacle to control fire pit operation Gas shut-off. Sleeve to outside of structure. 3 4" rigid gas line to house. Drainage from structure. Slope concrete to drain, daylight as required. 18 square inch opening (both sides) for ventilation. 3" Colorado Buff Stone Cap with 1" reveal 8" Poured in place Concrete Wall Note: See Structural Drawings for reinforcement, depth of footings, etc. (typ.) 12"-16" Tread 4" Colorado Buff Sandstone patio stone on a concrete slab with mortar joints. 6" thick Rose Sandstone steps (see Plan for layout and depth). Compact Subgrade to 95% S.P.D. prior to placing each successive step. Filter Fabric Compacted Road Base Landscape Boulders (see Plan) Provide pockets at steps for plantings 9'-6" overlap Poured-in-place concrete wall with waterproofing as required (both sides) Colorado Buff Sandstone landings on sand setting Slope to drain Dry Well: Provide a gravel well to absorb ground water as shown. Provide a protection layer of filter fabric Mirafi 140-N or equivalent. (no fabric on the bottom of the Well). Fill Well with 11 2" to 3" diameter clean rock (ASTM D-448 or better). Do not damage filter fabric during installation of rock. In bottom of well provide sump pump(s) as necessary to drain well. Verify all drainage methods with Civil Engineer. 4'-0" 1'-6" 15'-3" Filter Fabric Trench Drain Refer to Site Plan for layout (see detail this sheet) Steel Ledger 4" Fine Aggregate Base to Protect Liner. EPDM Pond Liner, Lap Joints Sealed in the Field. Sand Cushion if Required 4-6" River Rock Note: Flagstone Pavers to be Colorado Buff Sandstone. 2"-3" Thick Sandstone Pavers, Random Pattern 24" Min. Dia. Sand Setting Bed. Filter Fabric. Aggregate Base as Required by Soils Engineer. Compacted Subgrade. (Compaction per Soils Report.) 4" internal slope 4"-12" 12 " Expansion Joint with seal Typical Plan Section of Grate Cast Iron Sectional Grate Polymer Concrete trench drain assembled in the field per manufacturer's specifications Compacted Subgrade 4" concrete collar entire. See Structural drawings for reinforcement 4" aggregate backfill Adjacent Paving Depth as Required 5 1 Random Boulder (see Plan) Compacted Subgrade: Smooth Prepared Subgrade Free of Sharp Stones. Reinforced Slope as Required Turn back liner with Class 6 Road Base EPDM Pond Liner. Lap joints sealed in field. Sand cushion if required 4" Fine Aggregate Base to Protect Liner. Pond Level P.O. Box 1871 Avon Colorado 81620 (970) 390-6550 ric@fieldscape.net c Issue Date Sheet: Of: four L4 Pond Layout Plan The Fagan Residence Lot 7, Second Amendment to the Lia Zneimer Subdivision, Town of Vail, Eagle County, Colorado Copyright Fieldscape Incorporated All Rights Reserved This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Fieldscape Incorporated and is not to be used, in whole or in part, for any other project without the written authorization of Ric Fields Owner Sept. 3, '16 Fire Pit Wall Detail 3/4"=1'-0" 401 Sandset Stone Walkway Detail 1"=1'-0" 402 Trench Drain Section 1"=1'-0" 403 Typical Pond Edge Detail 3/4"=1'-0" 404 T.O.V. Apr. 3, '17 DRB APPROVED 7/5/2017 12:00:00 AM