HomeMy WebLinkAboutDRB17-0142_OrigA20_1495129440.pdfNORTH UNIT SOUTH UNIT LOWER LEVEL FLOOR PLAN SCALE: 1/4" = 1'-0" 1 A2.0 0 1 2 4 8 EXIST TO REMAIN REPLACE WINDOW EXIST TO REMAIN EXIST TO REMAIN EXIST TO REMAIN REMOVE NEW DECK ABOVE RE: MAIN LEVEL PLAN 1/A2.0 EXISTING DECK ABOVE RE: MAIN LEVEL PLAN 1/A2.0 8x8 WOOD DECK POST - STAINED TO MATCH DECK SUPPORTS (TYPICAL OF THREE) REMOVE (2) LOWEST RISERS ADD NEW LANDING AT NEW ELEVATOR ADD (2) RISERS TO NEW LANDING EXISTING DECK ABOVE RE: MAIN LEVEL PLAN 1/A2.0 EXISTING DECK SUPPORT NEW OPENING IN EXISTING WALL FOR ACCESS TO NEW ELEVATOR NEW 6'x6'-6" (OUTSIDE DIM) ELEVATOR TOWER LANDSCAPE STAIR TO GRADE (TO BE COORDINATED) NEW WOOD STAIR ABOVE 1. AT NEW WINDOWS & GLASS EXTERIOR DOORS: x CLAD TO MATCH EXISTING LOWER LEVEL WINDOWS. x GLAZING TO BE INSULATED GLASS SUITABLE FOR INSTALLATION. ABOVE 8000' (ALTITUDE) AND TEMPERED WHERE REQUIRED BY CODE. x TO HAVE AN U VALUE OF .32 OR LESS PER 2015 IECC. 2. REPLACE ALL WINDOWS AT THE MAIN AND UPPER LEVELS. AT REPLACEMENT WINDOWS: x CLAD TO MATCH EXISTING LOWER LEVEL WINDOWS. x GLAZING TO BE INSULATED GLASS SUITABLE FOR INSTALLATION. ABOVE 8000' (ALTITUDE) AND TEMPERED WHERE REQUIRED BY CODE. x TO HAVE AN U VALUE OF .32 OR LESS PER 2015 IECC. 3. VERIFY EXISTING WINDOW HEAD HEIGHT BEFORE ORDERING NEW WINDOWS - NEW WINDOW HEIGHT TO ALIGN WITH HEAD HEIGHT AT ADJACENT WINDOWS. WINDOW NOTES: LEGEND: EXISTING CONSTRUCTION TO REMAIN NEW WALL CONSTRUCTION EXISTING CONSTRUCTION TO BE REMOVED 1. SEE SHEET A1.0 FOR GRFA CALCULATIONS NOTES: SORTE RENOVATIONS LOT 34, GLEN LYON SUBDIVISION 1259N WESTHAVEN CIRCLE VAIL, COLORADO A2.0 SEE EXISTING PLANS FOR FULL FLOOR PLAN @ SOUTH UNIT RE: EA2.0 DRB APPROVED 5/18/2017 12:00:00 AM