HomeMy WebLinkAboutDRB17-0142_OrigA22_1495129440.pdfNORTH UNIT SOUTH UNIT
UPPER LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"
1
A2.2
0 1
2
4
8
REMOVE EXISTING WINDOW
-INFILL WALL
NEW 6'x6'-6" (OUTSIDE DIM)
ELEVATOR TOWER
NEW OPENING IN EXISTING WALL
FOR ACCESS TO NEW ELEVATOR
REPLACE WINDOW
REPLACE WINDOW
REPLACE WINDOW REPLACE WINDOW
REPLACE WINDOW
REPLACE WINDOW
REPLACE
WINDOW
REPLACE WINDOW
REPLACE WINDOW
NEW EGRESS WINDOW
1. AT NEW WINDOWS & GLASS EXTERIOR DOORS:
x
CLAD TO MATCH EXISTING LOWER LEVEL WINDOWS.
x
GLAZING TO BE INSULATED GLASS SUITABLE FOR
INSTALLATION. ABOVE 8000' (ALTITUDE) AND TEMPERED
WHERE REQUIRED BY CODE.
x
TO HAVE AN U VALUE OF .32 OR LESS PER 2015 IECC.
2. REPLACE ALL WINDOWS AT THE MAIN AND UPPER LEVELS. AT
REPLACEMENT WINDOWS:
x
CLAD TO MATCH EXISTING LOWER LEVEL WINDOWS.
x
GLAZING TO BE INSULATED GLASS SUITABLE FOR
INSTALLATION. ABOVE 8000' (ALTITUDE) AND TEMPERED
WHERE REQUIRED BY CODE.
x
TO HAVE AN U VALUE OF .32 OR LESS PER 2015 IECC.
3. VERIFY EXISTING WINDOW HEAD HEIGHT BEFORE ORDERING
NEW WINDOWS - NEW WINDOW HEIGHT TO ALIGN WITH HEAD
HEIGHT AT ADJACENT WINDOWS.
WINDOW NOTES:
LEGEND:
EXISTING CONSTRUCTION TO
REMAIN
NEW WALL CONSTRUCTION
EXISTING CONSTRUCTION TO
BE REMOVED
1. SEE SHEET A1.0 FOR GRFA CALCULATIONS
NOTES:
SORTE RENOVATIONS
LOT 34, GLEN LYON SUBDIVISION
1259N WESTHAVEN CIRCLE
VAIL, COLORADO
A2.2
SEE EXISTING PLANS FOR
FULL FLOOR PLAN @ SOUTH
UNIT RE: AE2.0
DRB
APPROVED
5/18/2017
12:00:00 AM