HomeMy WebLinkAboutDRB17-0142_OrigA30_1495129440.pdfEXISTING ROOF
MATERIAL TO REMAIN
EXISTING
STUCCO
TO REMAIN
EXISTING
STUCCO
TO REMAIN
EXISTING
STUCCO
TO REMAIN
DASHED LINE REPRESENTS THE
WINDOWS TO BE REMOVED
NEW 12' WIDE BY 10' TALL CLAD
SLIDING DOOR - DARK BRONZE
CLAD TO MATCH EXISTING
(VERIFY HEIGHT w/ADJACENT
WINDOW HEAD HEIGHT)
NEW TRAPEZOID CLAD WINDOW -
DARK BRONZE CLAD WINDOW TO
MATCH EXISTING
NEW WOOD WINDOW TRIM TO
MATCH EXISTING TRIM @
WINDOWS IN STUCCO
ALL WINDOWS AT THE LOWER
LEVEL TO REMAIN (TYPICAL)
EXISTING DECK AND RAIL TO
REMAIN
VERIFY EXISTING WINDOW HEAD
HEIGHT BEFORE ORDERING NEW
WINDOWS - NEW WINDOW HEIGHT
TO ALIGN HEAD WITH ADJACENT
WINDOWS
1. AT NEW WINDOWS & GLASS EXTERIOR DOORS:
x
CLAD TO MATCH EXISTING LOWER LEVEL WINDOWS.
x
GLAZING TO BE INSULATED GLASS SUITABLE FOR
INSTALLATION. ABOVE 8000' (ALTITUDE) AND TEMPERED
WHERE REQUIRED BY CODE.
x
TO HAVE AN U VALUE OF .32 OR LESS PER 2015 IECC.
2. REPLACE ALL WINDOWS AT THE MAIN AND UPPER LEVELS. AT
REPLACEMENT WINDOWS:
x
CLAD TO MATCH EXISTING LOWER LEVEL WINDOWS.
x GLAZING TO BE INSULATED GLASS SUITABLE FOR
INSTALLATION. ABOVE 8000' (ALTITUDE) AND TEMPERED
WHERE REQUIRED BY CODE.
x
TO HAVE AN U VALUE OF .32 OR LESS PER 2015 IECC.
3. VERIFY EXISTING WINDOW HEAD HEIGHT BEFORE ORDERING
NEW WINDOWS - NEW WINDOW HEIGHT TO ALIGN WITH HEAD
HEIGHT AT ADJACENT WINDOWS.
WINDOW NOTES:
SORTE RENOVATIONS
LOT 34, GLEN LYON SUBDIVISION
1259N WESTHAVEN CIRCLE
VAIL, COLORADO
A3.0
WEST ELEVATION
SCALE: 1/4" = 1'-0"
DRB
APPROVED
5/18/2017
12:00:00 AM