Loading...
HomeMy WebLinkAboutDRB17-0149 A2.1UP UP UP DN D E5 EC E2 E3 EB EF EE ED EG E4 20' - 0" 10' - 0" 10' - 0" E1 E6 EXISTING FAMILY ROOM EXISTING BUILDING NO CHANGES EXISTING BATH EXISTING LAUNDRY EXISTING KITCHEN/LIVING/DINING NEW LANDING AND STEP AT SAME LEVEL AS ENTRY FLOOR EXISTING DOOR TO BE REMOVED AND REPLACED WITH NEW EXTERIOR DOOR NOTE: GC TO MAINTAIN EXISTING FIRE SEPARATION WALLS BETWEEN DWEILLING UNITS EXISTING STORAGE NEW INTERIOR WALL AND DOOR EXISTING ENTRY 1A ADJACENT UNIT NOT IN CONTRACT NO CHANGES EXISTING DECK NO CHANGES E5 EC E2 E3 EB EF EE ED EG E4 E1 E6 NEW OWNER'S CLOSET 3 1/2" EXISTING 5' - 3" EXISTING BUILDING NO CHANGES BEDROOM 2 BATH 3 MASTER BATH MASTER BEDROOM EQ EQ EXISTING PARTIAL WALL TO BE FRAMED TO ROOF; PROVIDE NEW 4'-0"x5'-0" +/- GLAZED INTERIOR WINDOW A2.1 3 NOTE: GC TO MAINTAIN EXISTING FIRE SEPARATION WALLS BETWEEN DWEILLING UNITS EXISTING DOUBLE SLIDING DOOR TO BE REMOVED AND REPLACED WITH NEW EXTERIOR DOOR NEW INETRIOR WALL AND DOOR TO BE INSTALLED TO CREATE NEW STORAGE CLOSET EXIS TING 5' - 0 1/2" 3 1/2" EXISTING 5' - 3" EXIS TING 5' - 0 1/2" 2A ADJACENT UNIT NOT IN CONTRACT NO CHANGES E2 E3 EF EE EG E4 EXISTING BATHTUBS TO BE REMOVED AND REPLACED WITH PRE-FABRICATED SHOWER PANS. USE TILE REDI BATHTUB REPLACEMENT SHOWER PANMODEL: 3060RSPVC-13-2-4 OR EQUAL. PROVIDE MINIMUM 1,300 SQ IN CROSS SECTIONAL AREA MEASURED FROM FINISHED SURFACES BATH 3 BEDROOM 2 MASTER BATH MASTER BEDROOM EXISTING BUILDING NO CHANGES NOTES: 1. GC TO MAINTAIN EXISTING FIRE SEPARATION WALLS BETWEEN DWEILLING UNITS 2. ALL EXISTING BATHROOM WALL AND FLOOR FINSIHES, FIXTURES, FITINGS, CASEWORK, COUNTER TOPS TO BE REMOVED AND REPLACED WITH LIKE, SUPLIED AND/OR SPECIFIED BY OWNER 3. ALL OTHER EXISTING WALLS, FLOORS, DOORS, ETC. TO REMAIN UNCHANGED EXISTING 5' - 0 1/2" V.I.F. EXISTING 2' - 1" V.I.F. 3 1/2" EXISTING 3' - 8 1/2" V.I.F. 3 1/2" EXISTING 5' - 0 1/2" V.I.F. EXISTING 2' - 1" V.I.F. 3 1/2" EXISTING 4' - 11" V.I.F. 3 1/2" EXISTING 5' - 3" V.I.F. LEVEL 4 108' - 0" ENTRY 100' - 0" EC LEVEL 1 95' - 6" EB LEVEL 5 112' - 6" LEVEL 3 104' - 6" ED EXISTING DOUBLE SLIDING DOOR TO BE REMOVED AND REPLACED WITH NEW EXTERIOR DOOR EXISTING DOOR TO BE REMOVED AND REPLACED WITH NEW EXTERIOR DOOR ADJACENT UNIT NOT IN CONTRACT NO CHANGES DOOR TYPE 1 SINGLE LEAF, HINGED INSULATED, LOW E GLASS WOOD FRAME, ALUMINUM CLAD BRONZE COLOR E5 E2 E3 EF EE EG E4 E6 BEDROOM 2 MASTER BATH MASTER BEDROOM BATH 3 WALL MOUNTED VANITY LIGHT FIXTURE (TYP) 6" RECESSED CAN LIGHT (TYP) SURFACE MOUNTED CEILING FAN 3' - 0" 3' - 0" 3' - 0" 3' - 0" EQ EQ EQ EQ Scale Project Number: Drawn by: Checked by: mpp design shop, inc. PO Box 288 95 Willowstone Place Gypsum, CO 81637 (970) 390-4931 michael@mppdesignshop .com As indicated A2.1 PLANS, ELEVATIONS, SCHEDULES 1602 mpp mpp Baggaley Residence Addition HBM Townhouses Parcel 5 Parcel No: 2101-122-20-005 4352 Spruce Way, #5 Vail, CO 81657 1/4" = 1'-0" 1 LOWER LEVEL FLOOR PLAN 1/4" = 1'-0" 2 UPPER LEVEL FLOOR PLAN # Description Date 1 DRB/Variance Subm'n 10/28/16 2 DRB Submission 01/08/17 3 DRB/Building Permit 04/04/17 1/2" = 1'-0" 3 UPPER LEVEL FLOOR PLAN - DETAIL 1/4" = 1'-0" 4 EAST ELEVATION DOOR SCHEDULE Level Mark Type Width Height Comments LEVEL 3 2A 1 2' - 6" 6' - 8" Exterior LEVEL 1 1A 1 2' - 6" 6' - 8" Exterior 1: 2 Grand total: 2 1/4" = 1'-0" 5 UPPER LEVEL RCP / ELECTRICAL PLAN DRB APPROVED 5/2/2017 12:00:00 AM