Loading...
HomeMy WebLinkAboutDRB17-0171_A0-04_1499707140.pdfUP UP DN UP DN UP DN DN WP 4 WP WP WP WPWP WP WP WP WP WPWPWP 43 WP WP 4 FD FD FD WP FD FD FD FD FD FD DN                                                              ߰!" #! !"# !$$ ! !  ! ! "$#  ߰!" !  ߰!"  $! ߰$!" %$! 26.9 27.5 28.0 28.4 29.0 29.7 30.2 27.2 27.9 28.8 $ %   DN DN .39 x 2265 SF = 885 SF A0.04 7 A0.0412 A0.04 8 A0.04 9 A0.04 10 A0.04 11 A4.03 A0.20 1 A0.21 1 2370 SF 1ST LEVEL 2ND LEVEL TOTAL SF 2780 + 220 SQ FT ENTRY LEVEL 1500 -900 = 600 SQ FT 3RD LEVEL 885 SQ FT 6853 SQ FT TOTAL AVAILABLE GRFA - PRIMARY / SECONDARY GRFA RATIO SITE AREA 10,000 SF X .46 = 4600 SF 5,000 SF X .38 = 1900 SF 2730 x .13 = 354 SF 6,854 SF MAX GRFA 0.46 of site area  10,000 sq. ft., plus 0.38 of site area > 10,000 and  15,000 sq. ft., plus 0.13 of site area > 15,000 and  30,000 sq. ft., plus 0.06 of site area > 30,000 sq. ft. 17,730 SF (.407 ACRES) MAX GRFA AVAILABLE MAX SITE COVERAGE 20% OF TOTAL SITE 17,730 SF X .2 = 3,546 SF TOTAL PROPOSED SQUARE FOOTAGE OVERVIEW 1ST LEVEL 2ND LEVEL TOTAL SF 3000 SQ FT ENTRY LEVEL 1500 SQ FT 2370 SQ FT 3RD LEVEL 2265 SQ FT 9135 SQ FT (2265 SF X .39 EXPOSED 885 SF NET) TOTAL PROPOSED GRFA OVERVIEW 2368 SQ FT 6853 SQ FT DRIVEWAY 1375 SQ FT SITE COVERAGE 3535 SQ FT TOTAL 1240 SQ FT ALLOWED 3,546 SF PROPOSED 2780 SF 220 SF 1500 SF TOTAL -900 SF GARAGE 600 SF NET 3453 SF SITE COVERAGE 70 SF ROOF OVER 4'-0" SITE COVERAGE ARCH. PROJECTION 3523 SF SITE COVERAGE (TOTAL W/ OVERHANGS) 398 SF TOTAL, 295 SF UNDER GRADE 307 SF TOTAL, 307 SF UNDER GRADE 124 SF TOTAL, 124 SF UNDER GRADE 203 SF TOTAL, 203 SF UNDER GRADE 566 SF TOTAL, 0 SF UNDER GRADE 580 SF TOTAL, 375 SF UNDER GRADE 205 SF EXPOSED 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.04 GRFA STUDY RYAN RESIDENCE Project Number - 1668 807 POTATO PATCH DR VAIL, CO 81657 06/29/2017 DRB 1" = 20'-0" 1 3RD LEVEL - GRFA 1" = 20'-0" 2 2ND LEVEL - GRFA 1" = 20'-0" 3 1ST LEVEL - GRFA 1" = 20'-0" 4 ENTRY LEVEL GRFA 1/16" = 1'-0" 5 SITE COVERAGE NORTH 1" = 10'-0" 7 EAST ELEVATION - BASEMENT CALC 1" = 10'-0" 8 NORTH - BASEMENT CALC 1" = 10'-0" 9 BASEMENT GRFA 1" = 10'-0" 10 BASEMENT GRFA 2 1" = 10'-0" 11 SOUTH ELEVATION - BASEMENT CALC BASEMENT GRFA CALCULATIONS TOTAL BASEMENT WALL SF = 2272 SF TOTAL BASEMENT WALL SF EXPOSED = 897 SF TOTAL % EXPOSED = 39% 1" = 10'-0" 12 BASEMENT GRFA 3 1" = 20'-0" 6 ENTRY - 1ST GRFA    DRB APPROVED 7/5/2017 12:00:00 AM