Loading...
HomeMy WebLinkAboutDRB17-0173_Gulliford ~ SPEC, AC condenser info - MSY-GE18NA~MUY-GE18NA_1494364740.pdfJob Name:Location:Date: Purchaser:Engineer: Submitted to:For Reference Approval Construction System Designation:Schedule No.: © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. Cooling*Rated Capacity...............................17,200 Btu/hMinimum Capacity .............................3,700 Btu/hSEER ......................................19.2 Btu/h/WTotal Input......................................1,640 W* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB. Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzBreaker Size.......................................15 A VoltageIndoor - Outdoor S1-S2 ......................AC 208 / 230VIndoor - Outdoor S2-S3 .........................DC 12-24VIndoor - Remote Controller.........................Wireless OPERATING RANGE Indoor Intake Air Temp.Outdoor Intake Air Temp. Cooling Maximum 90°F (32°C) DB,73°F (23°C) WB 115°F (46°C) DB Minimum 67°F (19°C) DB,57°F (14°C) WB 14°F (-10°C) DB Indoor UnitMCA ...............................................1 AFan Motor.....................................0.76 F.L.A.Airflow (Quiet - Lo - Med - Hi - Super Hi) Cooling ................230 - 275 - 339 - 420 - 533 Dry CFM194 - 240 - 304 - 385 - 498 Wet CFM Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Cooling ........................28 - 33 - 38 - 44 - 49 dB(A) DIMENSIONS UNIT INCHES / MM W 31-7/16 / 799 D 9-1/8 / 232 H 11-5/8 / 295 Weight.....................................22 lbs. / 10 kgExternal Finish .....................Munsell No. 1.0Y 9.2 / 0.2Field Drainpipe Size O.D......................5/8" / 15.88 mm Outdoor UnitCompressor ...................DC Inverter-driven Twin RotaryMCA ..............................................14 AFan Motor.....................................0.93 F.L.A.Sound Pressure Level Cooling ......................................54 dB(A) DIMENSIONS INCHES / MM W 33-1/16 / 840 D 13 / 330 H 33-7/16 / 849 Weight ...................................119 lbs. / 54 kgExternal Finish ......................Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...................................R410ARefrigerant Pipe Size O.D. Gas Side .................................1/2" / 12.7 mm Liquid Side................................1/4" / 6.35 mmMax. Refrigerant Pipe Length....................100 ft. / 30 mMax. Refrigerant Pipe Height Difference ............50 ft. / 15 mConnection Method ................................Flared SUBMITTAL DATA: MSY-GE18NA & MUY-GE18NA 18,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEMS OPTIONAL ACCESSORIESOutdoor Unit □Drain Socket Assembly (MAC-811DS) Indoor Unit □Condensate Pump (230V; SI3100-230) Controller Options □Wall-mounted Wired Controller (PAR-21MAA; req. MAC-3971F) □MA Contact Terminal Interface (MAC-397IF) □M-NET Control Adapter (MAC-399IF) □Remote Temperature Sensor (M21-JKO-307) □Lockdown Bracket for Hand-held Controller (RCMKP1CB) GENERAL FEATURES• Wall-mounted indoor unit• Standard Hybrid Catechin Prefilter is included with indoor unit• Quiet operation• Choice of fan speeds: Quiet, Low, Medium, High, and Super High; Auto fan speed control also included• Hand-held Wireless Remote Controller• Indoor unit powered from outdoor unit using A-Control• Auto restart following a power outage• Anti-allergy Enzyme Filter • Limited warranty: five years on parts and defects and seven years on the compressor Indoor Unit: MSY-GE18NA Wireless Remote Controller Outdoor Unit: MUY-GE18NA 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice. © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC.FORM# MSY-GE18NA ~ MUY-GE18NA - 201108 DIMENSIONS: MSY-GE18NA & MUY-GE18NA MSY-GE18NA MUY-GE18NA