HomeMy WebLinkAboutDRB17-0186_A-010 EL-E_1497025260.pdfevoDOMUS LLC
3143 W 33rd Street
Cleveland, OH 44109
Phone : (216) 772-2603
Sheet Size:
24" x 36"
Sheet Number:
A-010
Phase:
Date:
Project
Number:
STM Project
Name:
Sturm
Residence
Client:
Issue & Revision History:
Edit.: Date: Description:
Elevation 3 East
Drawing:
Elevation 3 East
Scale:
1/4" = 1'-0"
DRB
5/15/2017
Paul and Leisa Sturm
5044 Main Gore Drive S
Vail, Colorado 81657
Devepoler / Plan Preparer:
Lot 2 Vail Meadows Filing No. 1
33'-0" (8623') 32'-51/8"
6'-6"
7'-0"
30'-5" (8620.58')
32'-37/8"
32'-10 7/8" (8622.9')
28'-117/8"
LOWEST POINT OF EXISTING GRADE
AT CORNER OF ROOF OVERHANG
EXISTING GRADE
EXISTING GRADE
LOWEST POINT OF FINISH GRADE
AT TOP OF ROOF OVERHANG
FFL +19'-9 1/4"
3rd FLOOR
FFL +28'-7 3/4"
ROOF
FFL +8'-11 1/2"
2nd FLOOR
FFL 0.00 = 8590'
1st FLOOR
Exterior Building Materials List
Building Material Type of Material Color
Roof TPO membrane Gray
Mfg - Firestone, GAF or equal
Siding 6" T&G horizontal, Natural weathered gray
heat modified Amer. Ash
Mfg - Thermory
Stone Quartzite stone veneer Beige / Gray
Mfg - Realstone Estate Stone
Panels Powder-coated Aluminum Dark Gray or Brown
OR Fiber Cement Board
Mfg - Equitone
Fascia 6" T&G horizontal, Natural weathered gray
heat modified Amer. Ash
Mfg - Thermory
Soffits 6" T&G horizontal, Natural weathered gray
heat modified Amer. Ash
Mfg - Thermory
Windows Wood w/ powder-coated Dark Gray or Brown
aluminum exterior cladding
Mfg - Unilux
Doors Wood w/ powder-coated Dark Gray or Brown
aluminum exterior cladding
Mfg - Unilux
Garage Doors Wood Natural weathered gray
Door Trim 6" T&G horizontal, Natural weathered gray
heat modified Amer. Ash
Mfg - Thermory
Hand or Deck Rails Powder-coated aluminum Dark gray or brown
cable railing w/ wood top rail
Mfg - Keuka
Flashing Powder-coated Aluminum Dark gray or brown
Chimney Realstone Estate Stone Beige / Gray
Trash enclosure Concrete retaining wall w/ Gray
Thermory screen Natural weathered gray
Exterior Lighting Tube wall sconce Dark Gray or Brown
Mfg WAC Lighting
Strut Bollard Dark Gray or Brown
Landscape Light
Mfg Tech Lighting
LEDme Step & Wall light Dark Gray or Brown
Mfg WAC Lighting
Driveway Exposed aggregate concrete
VARIES
SEE FLOOR PLANS
83/8"
73/4"
77/8" 4" VARIES
111/4" 63/4"
111/4" 6"
UNILUX WINDOW, SEE WINDOW SCHEDULE
LIFT AND SLIDE DOOR MAY OCCUR, SEE
BUILDING SPECIFIC PLANS.
DECKING MATERIAL, SEE DRAWINGS AND
SPECS.
TAPERED FRAMING @ 16" O.C. OVER
STRUCTURAL FRAMING; TAPER 1/4"/FT.;
RIP END PIECES AS REQ'D TO MATCH TAPER
EXTERIOR INTERIOR
3'-0"
GALVANIZED OR STAINLESS STEEL CABLE
RAILING SYSTEM; SEE SCHEDULES;
BOLT INTO BLOCKING WITH
LAG BOLTS PER MANUFACTURER'S
RECOMMENDATIONS
2x PT TAPERED SLEEPER @ 16" o.c.;
ATTACH EPDM STRIP TO SLEEPER TOP &
BOTTOM; TAPER SLEEPER MIN. 1/4" PER
FOOT TO EDGE OF GUTTER; SLEEPER TO
LEVEL OUT OVER GUTTER
EPDM ROOF MEMBRANE; FULLY ADHERED,
ON 3/4" PLYWOOD. WRAP OVER METAL
FLASHING AT WINDOW SILL AND GUTTER.
SELF ADHERED MEMBRANE FLASHING
5/8" ZIP SHEATHING
DRIP EDGE DETAIL. SEE SECTION 35
4" WIDE ALUMINUM GUTTER; SLOPE MIN.
1/8"PER FOOT; SEE ELEVATION FOR
DIRECTION OF SLOPE
3/4" PLYWOOD SHEATING; REF. SHOP
DRAWINGS FOR FASTENING
REQUIREMENTS
RECESSED LIGHT; SEE ELECTRICAL
SOFFIT, SEE BUILDING SPECIFIC PLANS
FOR SOFFIT DESIGNATION. SEE SOFFIT
DETAILS IN SECTION 35
2x6 PT FRAMING; SECURE TO BLOCKING
PAN FLASHING FOR LIFT/SLIDE UNIT
3" DIRECT APPLICATION ALUMINUM EIFS
VENT BY FLANNERY METALS; PART
NUMBER - PCS 625-V-300, OR EQUAL
CAP, SEE SPECS FOR SELECTION
EXTERIOR CLADDING; SEE ELEVATIONS
AND SPECIFICATIONS; SEE SECTION 35
(2) 1-3/4" x 11-1/4" LVL's; SEE SHOP
DRAWINGS FOR ADDITIONAL INFO.
2x6 JOIST @ 16" O.C. TO SUPPORT SOFFIT.
PT BLOCKING ON 1/2" PLYWOOD LAYER
ON 3/4" PLYWOOD LAYER
METAL FLASHING W/ DRIP EDGE ON
EITHER SIDE OF GUTTER
LC SCOPE
MC SCOPE 5/8"
61/8" 11/2"
3/4"
3/4"
93/4"
31/2"
ALUMINUM SILL PROVIDED BY
WINDOW MANUFACTURER; INSTALLED BY
SET CREW ON PT BLOCKING AS REQUIRED
FOR SUPPORT.
THERMORY SHIPLAP SIDING, FACE NAILED
WITH STAINLESS STEEL RINGSHANK NAILS
TO PT FURRING. FURRING TO ALIGN WITH
WALL STUDS.
UNILUX TURN-TILT WINDOW;
INSTALLATION BY PANEL MANUFACTURER
GASKET SUPPLIED BY WINDOW
MANUFACTURER; FIELD INSTALLED
SELF ADHESIVE BITUMINOUS FLASHING
SELF ADHESIVE BITUMINOUS FLASHING.
CONTINUE FROM SHEATHING TO COVER
DRIP CAP.
1 1/2" R-MATT PLUS®-3
POLYISOCYANURATE INSULATION (R9.6).
INSTALL WITH FOIL SIDE IN.
VINYL TRIPLE PANE WINDOW. SEE
SECTION 15 FOR INSTALLATION AND
FLASHING DETAILS.
THERMORY SHIPLAP SIDING, FACE NAILED
WITH STAINLESS STEEL RINGSHANK NAILS
TO PT FURRING. FURRING TO ALIGN WITH
WALL STUDS.
WOOD PANEL J MOLD BY FLANNERY
METALS. PART NO. WPJ 75-375.
1x4 TRIM TO MATCH SIDING
1x TRIM TO MATCH SIDING. SCRIBE
BOTTOM OF TRIM TO SILL.
WOOD PANEL J MOLD BY FLANNERY
METALS. PART NO. WPJ 75-375.
ORDER SILL 1" SHORTER THAN WINDOW
FRAME.
STUCCO DRIP STOP BY FLANNERY
METALS. COLOR TO MATCH SILL
WINDOW HEAD AND SILL SECTIONS
INTERIOR
STANDARD WINDOW JAMB DETAIL
INTERIOR
WINDOW JAMB AT FULL WIDTH INSIDE CORNER
WRAP TRIM BOARD AT SIDES, SEE JAMB
DETAIL. SCRIBE BOTTOM OF TRIM TO
SILL.
1X WOOD TRIM TO MATCH SIDING
2X4" PT NAILER, ALL SIDES OF WINDOW.
WRAP ZIP TAPE OVER SILL EDGE.
INSECT SCREEN; WRAP AROUND FURRING
NORTH ELEVATION
Typical Cable railing system at balcony Typical Thermory Siding at windows
DRB
APPROVED
6/7/2017 12:00:00
AM