HomeMy WebLinkAboutDRB17-0187_G-001_1497035460.pdfPROJECT:
SHEPHERD RESOURCES INC/AIA
970 949 3302
M
O C . T C E T I H R
A I R
P B OX 8 40
105 EDWAR DS BLVD
O ST FFI C E O
S U I T E C103
E D W A R DS C O 81 6 3 2
V I LLAGE
G-001
1408.04
MAY 15, 2017
PROJECT INFORMATION
LOT 10
303 GORE CREEK
DRIVE
GALVIN
RESIDENCE
DRB MODIFICATION TO
APPROVED PLANS
4 STORIES + BASEMENT
TYPE OF OCCUPANCY:
TYPE OF CONSTRUCTION:
LEVELS:
N/A
N/A
PROJECT INFORMATION
SOILS ENGINEER
ARCHITECT
STRUCTURAL ENGINEER
LANDSCAPE ARCHITECT
GENERAL CONTRACTOR
PROJECT DIRECTORY
INDEX OF DRAWINGS
SHEPHERD RESOURCES INC/AIA
P.O. Box 840
105 Edwards Village Blvd. Suite C103
Edwards, CO 81632
(Phone) 970.949.3302
CESARE, INC.
7108 S. Alton way, Building B
Centennial, CO 80112
(Phone) 303.220.0300
BECK BUILDING COMPANY
P.O. Box 4030
Vail, CO 81658
(Phone) 970.949.1800
HEIGHT: 37'-10 1/4" MAX.
PARKING: 2
FIRE SUPPRESSION SYSTEM: YES
CURRENT APPLICABLE CODES:
PARCEL NUMBER: 2101-082-31-009
LEGAL DESCRIPTION: VAIL VILLAGE FILING 1 BLOCK: 5, LOT 10
AKA VAIL ROWHOUSE UNIT 10
CLASS OF WORK: DEMO/REBUILD
INTERIOR FIXED FINISHES
2015 IRC
2015 IFC
2015 IPC
2015 IMC
2012 IFGC
2015 IECC
OWNER
MARTIN/MARTIN, INC.
P.O. Box 8896
0101 Fawcett Road, Suite 260
Avon, CO 81620
(Phone) 970.926.6007
David Beadle
5543 Bitterbush Way
Loveland, CO 80537
(Phone) 970.663.4170
CIVIL ENGINEER
ALPINE ENGINEERING
P.O. Box 97
Edwards, CO 81632
(Phone) 970.926.3373
M.E.P. ENGINEER
TBD
DATUM REFERENCE
COPYRIGHT RESERVATION
DATUM ELEVATION OF 7965'-0"
EQUALS ACTUAL ELEVATION OF7965'-0" ABOVE SEA LEVEL
FF=
XXX'-X"
TOP OF FINISHED FLOOR
T O X
XXX'-X"
TOP OF PLYWOOD (P) OR CONCRETE (C)
PROJECT NORTH
THIS SYMBOL REFERS TO ACTUAL NORTH.
ALL DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE ARCHITECT (DOUGLAS MILLER DECHANT ARCHITECTS / SHEPHERD RESOURCES, INC./ AIA HERE IN AFTER , "SRI") FOR PROJECTS FOR WHICH
THE ARCHITECT HAS BEEN RETAINED ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE FOR USE SOLELY WITH RESPECT TO THE SPECIFIC PROJECT, UNLESS OTHERWISE PROVIDED IN WRITING, THE ARCHITECT SHALL BE
DEEMED THE SOLE AND EXCLUSIVE AUTHOR OF SUCH DOCUMENTS AND SHALL RETAIN, WITHOUT LIMITATION, ALL COMMON LAW, STATUTORY AND OTHER REVERSED RIGHTS, INCLUDING THE COPYRIGHT HEREOF.
NO PERSON (INCLUDING, WITHOUT LIMITATION, ALL EMPLOYEES AND/OR INDEPENDENT CONTRACTORS OF THE ARCHITECT), WHETHER HAVING COME RIGHTLY INTO POSSESSION THERE OF OR OTHERWISE, SHALL
EMPLOY THESE DOCUMENTS ON ANY OTHER PROJECT, NOR FOR ADDITIONS TO ANY PROJECT NOR FOR THE COMPLETION OF ANY PROJECT FOR WHICH THE ARCHITECT HAS BEEN RETAINED BY OTHERS, OR MAKE
ANY OTHER USE THEREOF WHATSOEVER, UNLESS WITH THE PRIOR EXPRESS WRITTEN CONSENT OF THE ARCHITECT AND UPON APPROPRIATE COMPENSATION TO THE ARCHITECT IN AN AMOUNT AND KIND PRIOR
EXPRESS WRITTEN CONSENT OF THE ARCHITECT AND UPON APPROPRIATE COMPENSATION TO THE ARCHITECT IN AN AMOUNT AND KIND IN ALL MATERIAL FOR WHICH ARE ISSUED IN CONFIDENCE FOR DESIGN
AND/OR CONSTRUCTION PURPOSES OF ALL PROJECTS FOR WHICH THE ARCHITECT HAS BEEN RETAINED AS NOTED. THESE MATERIALS MAY NOT BE COPIED, MODIFIED, NOR EMPLOYED IN ANY WAY BY ANY PERSON
(INCLUDING, WITHOUT LIMITATION, AN EMPLOYEE ORE EMPLOYEES) WITHOUT THE SPECIFIC PRIOR WRITTEN CONSENT AND PERMISSION OF THE ARCHITECT. THE FOREGOING SHALL APPLY EQUALLY TO ALL
CONCEPT DRAWINGS, RENDERINGS, SKETCHES, BIDS AND ALL OTHER WORK PRODUCT OF THE ARCHITECT EVEN IN THE EVENT THAT THE ARCHITECT IS NOT ULTIMATELY RETAINED FOR THE SPECIFIC PROJECT FOR
WHICH SUCH MATERIALS WERE CREATED AND TO ALL OTHER WORKS AND WORK PRODUCT OF THE ARCHITECT.
(C) 2017 DOUGLAS MILLER DECHANT ARCHITECTS / SHEPHERD RESOURCES, INC. ALL RIGHTS RESERVED.
ALL ISSUANCES SHALL BE DISTRIBUTED IN FULL, WHICH INCLUDES BUT IS NOT LIMITED TO, ALL OF THE SHEETS LISTED IN THE INDEX OF DRAWINGS ON THIS SHEET, THE DETAIL MANUAL, THE PROJECT MANUAL,
ADDENDA AND ARCHITECTURAL SUPPLEMENTAL INSTRUCTIONS. PLEASE CONTACT THE GENERAL CONTRACTOR IF YOU HAVE NOT RECEIVED A COMPLETE SET OF DOCUMENTS.
ABBREVIATIONS
PT
QT
RE:
REF
REQD
RESL
REV
R
R & S
RD
RM
RO
R/S
SHLDR
SIM
SPEC
SQ
SF
STD
STL
STN
STRUCT
TBD
TC
TEL
TV
T & G
T O B
T O C
T O F
T O P
T O S
T O W
TB
T
TYP
UNO
VERT
WC
WP
WPM
WPT
WWF
W
WDW
W/
W/O
WD
GL GLASS, GLAZING
GWB GYPSUM WALL BOARD
HDWR HARDWARE
HDR HEADER
HVAC HEATING/VENTILATING/AIR
CONDITIONING
HT HEIGHT
HP HIGH POINT
HORZ HORIZONTAL
HB HOSE BIB
HR HOUR
INCL INCLUDE (D), (ION)
ID INSIDE DIAMETER
IBC INSTALLED BY CONTRACTOR
IBO INSTALLED BY OWNER
INSUL INSULATION
INT INTERIOR
KIT KITCHEN
LAM LAMINATE
LAV LAVATORY
L LENGTH
LTL LINTEL
LVL LAMINATED VENEER LUMBER
MFR MANUFACTURE (ER)
MO MASONRY OPENING
MATL MATERIAL
MAX MAXIMUM
MTL METAL
MECH MECHANICAL
MC MEDICINE CABINET
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MNT MINUTE
NA NOT APPLICABLE
NOM NOMINAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OPG OPENING
OPP OPPOSITE
OPH OPPOSITE HAND
OD OUTSIDE DIAMETER
(P) PASSIVE
P PAINT
PR PAIR
PVMT PAVEMENT
PL PLATE
PLYWD PLYWOOD
ABV ABOVE
AFF ABOVE FINISHED FLOOR
(A) ACTIVE
AC ACOUSTICAL
ADD ADDENDUM
ADJ ADJACENT
ALT ALTERNATE
ALUM ALUMINUM
ARCH ARCHITECT (URAL)
BASMT BASEMENT
BRG BEARING
BR BEER
BIT BITUMINOUS
BLDG BUILDING
B O H BOTTOM OF HEADER
CPT CARPET
CSMT CASEMENT
CLG CEILING
CT CERAMIC TILE
CLR CLEAR (ANCE)
COL COLUMN
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONT CONTINUOUS
CUST CUSTOM
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DR DOOR
DWG DRAWING
ELEC ELECTRIC (AL)
ELEV ELEVATION
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FOS FACE OF STUDS
FIN FINISH
FF FINISHED FLOOR
FP FIREPLACE
FLR FLOOR (ING)
FD FLOOR DRAIN
FTG FOOTING
FND FOUNDATION
FBO FURNISHED BY OTHERS
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
POINT
QUARRY TILE
REFERENCE
REFRIGERATOR
REQUIRED
RESILIENT
REVISION
RISER
ROD AND SHELF
ROOF DRAIN
ROOM
ROUGH OPENING
ROUGH SAWN
SHOULDER
SIMILAR
SPECIFICATION (S)
SQUARE
SQUARE FEET
STANDARD
STEEL
STRUCTURAL
TO BE DETERMINED
TRASH COMPACTOR
TELEPHONE
TELEVISION
TONGUE AND GROOVE
TOP OF BEAM
TOP OF CONCRETE SLAB
TOP OF WINDOW/DOOR FRAME
TOP OF PLYWOOD
TOP OF STEEL
TOP OF WALL
TOWEL BAR
TREAD
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
WATER CLOSET
WATERPROOFING
WATERPROOFING MEMBRANE
WORKPOINT
WELDED WIRE FABRIC
WIDTH, WIDE
WINDOW
WITH
WITHOUT
WOOD
STONE
BIB BLOWN IN BLANKET INSUL
1. ALL DISTRIBUTIONS OF THESE DRAWINGS BY THE GENERAL CONTRACTOR SHALL INCLUDE ALL ADDITIONAL
DOCUMENTS ASSOCIATED WITH THIS ISSUE. THESE DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, PROJECT
MANUAL, SPECIFICATIONS, AND DETAIL MANUAL. FURTHERMORE, NONE OF THE ADDITIONAL DOCUMENTS SHALL BE
DISTRIBUTED WITHOUT THESE DRAWINGS.
2. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE
ARCHITECT RESERVES THE RIGHT TO TAKE EXCEPTIONS TO METHODS AND MATERIALS NOT REFLECTED HEREIN.
3. WORK SHALL BE PERFORMED IN A WORKMANLIKE OR CRAFTSMANLIKE MANNER TO THE SATISFACTION OF THE OWNER.
4. THE DRAWINGS SHALL NOT BE SCALED TO DETERMINE CONSTRUCTION DIMENSIONS. THE CONTRACTOR AND
EACH SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO EXECUTION OF THE WORK, AND SHALL BE
RESPONSIBLE FOR THE CORRECT AND ACCURATE LAYOUT AND CONSTRUCTION OF THE PROJECT.
5. DIMENSIONS ARE TO FACE OF STUD OR TIMBER, CENTERLINE OF TIMBER AND FACE OF CONCRETE, UNLESS NOTED
OTHERWISE.
6. DENOTES
A DOOR. REFER TO PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE.
7. DENOTES A WINDOW. REFER TO PLANS, SECTIONS, AND ELEVATIONS FOR WINDOW LOCATIONS. REFER TO
WINDOW SCHEDULE.
8. REFER TO INTERIORS DOCUMENTS FOR ROOM FINISH SCHEDULE.
9. COORDINATE ELECTRICAL AND MECHANICAL WORK WITH STRUCTURAL FRAMING.
10. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO
TOILETS, BATH ACCESSORIES, CEILING AND WALL MOUNTED ELECTRICAL FIXTURES, SHELVES, CLOSET RODS,
CABINETRY, COUNTER TOPS, STAIR HANDRAILS AND FALSE BEAMS.
11. CONFIRM DATUM INFORMATION WITH CIVIL PLANS.
12. ALL NON 90 DEGREE ANGLES ON PLANS ARE 45 DEGREES UNLESS OTHERWISE NOTED.
13. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. FLOOR PLANS TAKE PRECEDENCE.
14. ALL ARCHES ARE TO HAVE A RADIUS THAT EQUALS THE WIDTH OF THE OPENING. THE SPRING LINE OF THE
ARCH IS LOCATED AT 7'0" AFF. UNLESS NOTED OTHERWISE.
15. WOOD/TIMBER MEMBERS NOTED WITH " (INCH) MARKS REFERS TO THE ACTUAL FINISHED DIMENSION OF THE MEMBER.
FOR EXAMPLE 4"X12" REFERS TO A MEMBER THAT MEASURES 4 INCHES WIDE BY 12 INCHES DEEP. MEMBERS
NOTED WITHOUT " (INCH) MARKS REFERS TO THE NOMINAL FINISHED DIMENSIONS OF THE MEMBER. FOR EXAMPLE 4X12
REFERS TO A MEMBER THAT MEASURES 3 1/2 INCHES WIDE BY 11 1/4 INCHES DEEP. REFER TO SPECIFICATIONS FOR
SURFACE TEXTURE AND FINISH.
16. INSTALL PERFORATED PIPE PERIMETER DRAIN AND SOLID PIPE UNDER DRAIN SYSTEMS AS REQUIRED BY THE
SOILS REPORT. SLOPE SYSTEM TO DRYWELL OR DAYLIGHT. ALL DOWNSPOUTS ATTACHED
TO SOLID PIPE DRAIN SYSTEM AND HEAT TRACED TO 48" BELOW FINISHED GRADE.
17. TYPICAL OFFSET OF INTERIOR DOORS IS 6", UNLESS AT END OF CORRIDOR (WHERE THEY ARE CENTERED), OR UNO.
18. ALL WINDOW AND DOOR DIMENSIONS ARE TO CENTERLINE OF UNIT, UNO.
19. RADON MITIGATION SYSTEM TO BE DESIGN/BUILD W/ SUBCONTRACTOR.
20. THE ARCHITECT & THE ARCHITECT'S CONSULTANT SHALL HAVE NO RESPONSIBILITY(IES) FOR THE DISCOVERY, PRESENCE,
HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS OR TOXIC SUBSTANCES IN
ANY FORM AT THE PROJECT SITE.
GENERAL NOTES
X
X X X
NO SCALE
VICINITY MAP
DATE ISSUE
2/20/2017 DRB Final Review
5/15/17 DRB Modification to Approved Plans
G-100 COVER SHEET
G-001 PROJECT INFORMATION
V-100 SURVEY
V-101 HISTORIC GRADE
C-100 UTILITY PLAN EXISTING CONDITIONS
C-101 UTILITY PLAN PROPOSED
C-102 UTILITY DETAILS
L-100 EXISTING CONDITIONS / DEMO SITE PLAN
L-101 SITE & GRADING PLAN
L-102 LANDSCAPE PLAN
A-100 FLOOR PLAN LEVEL 1 & 2
A-101 FLOOR PLAN LEVEL 3 & 4
A-102 FLOOR PLAN LEVEL 5 & ROOF PLAN
A-103 ROOF HEIGHTS
A-200 EXTERIOR ELEVATIONS
COMBINED LOTS 9 & 10
A-201 EXTERIOR ELEVATION SOUTH & NORTH
A-202 EXTERIOR ELEVATION EAST
A-203 EXTERIOR ELEVATION WEST
A-600 LANDSCAPE AREA CALCULATION
A-601 SITE COVERAGE LEVEL 1 & 2
A-602 SITE COVERAGE LEVEL 3 & 4
A-603 SITE COVERAGE LEVEL 5 & CONSOLIDATED
A-900 3D PERSPECTIVES
A-901 3D PERSPECTIVES
A-902 3D PERSPECTIVES
E-100 EXTERIOR LIGHTING CUT SHEETS
E-101 EXTERIOR LIGHTING PLANS
LOT SIZE : .054 ACRES (2,334 SF)
SITE COVERAGE : 1,274 SF
REFERENCE SHEETS A-601-603 FOR GRAPHIC INDICATION
NOT APPLICABLE APPLICABLE
LEVEL 1 = 755 SF
LEVEL 2 = 1,230 SF
LEVEL 3 = 1,176 SF
LEVEL 4 = 1,262 SF
LEVEL 5 = 1,127 SF
GRFA TOTAL : 4,795 SF
GRFA EXISTING : (DEDUCTED) 2,477 SF
GRFA NEW : 2,318 SF
LANDSCAPE AREA : 700 SF
LANDSCAPE AREA (PAVED) : 140SF
DRB
APPROVED
6/7/2017 12:00:00
AM