HomeMy WebLinkAboutDRB17-0192_A000_1496767020.pdfA000
COVER SHEET
P R O J E C T :
ROZZELL
RESIDENCE
D R A W N B Y :
D A T E :
R E V I S I O N S :
1350 GREENHILL
COURT
VAIL, COLORADO
05.16.17
-
ROZ17
Rozzell Residence
1350 GREENHILL COURT, VAIL, COLORADO
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY
WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN
APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE
PARTICULAR AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD
COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION
DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR
BEAMS UNLESS OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE
BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET
ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR
TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR
WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR
AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR
FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY
THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A
DELAY IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE
CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. COMPLIANCE WITH ALL
CURRENT CODES IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT
WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING THE INTERNATIONAL
BUILDING CODE AND ALL LOCAL AND REGIONAL CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND
OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR
DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE
BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY
SITE WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF &
DECK SURFACES MUST BE MAINTAINED REASONABLY FREE OF ICE & SNOW TO ENSURE
MINIMAL PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S
WRITTEN APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL
CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS
TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE
RECOGNIZED STANDARDS OF THE INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE
SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING
UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION
IMPACTS TO THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE
ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION.
ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED
LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE
CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS
FOR LAYOUT; IN CASE OF ANY DISCREPANCIES VERIFY WITH ARCHITECT.
A 000 COVER SHEET
ARCHITECTURAL
A 101 EXISTING LOWER LEVEL PLAN
A 102 PROPOSED LOWER LEVEL PLAN
A 103 EXISTING MAIN LEVEL PLAN
A 104 PROPOSED MAIN LEVEL PLAN
A 105 EXISTING UPPER LEVEL PLAN
A 106 PROPOSED UPPER LEVEL PLAN
A 201 EXISTING AND PROPOSED EAST ELEVATION
CODE:
2015 INTERNATIONAL RESIDENTIAL CODE
ZONING:
SDD #4
OCCUPANCY CLASSIFICATION:
TYPE R, DIV. 3
CONSTRUCTION CLASSIFICATION:
TYPE V-B
PROJECT LOCATION:
1350 GREENHILL COURT
VAIL, COLORADO
81657
N
PROJECT SUMMARY: DRAWING INDEX:
PROJECT TEAM:
ARCHITECT:
CURRENT ARCHITECTS
PO BOX 9253
VAIL, CO 81657
WWW.CURRENTARCHITECTS.COM
PHONE: 970-331-6345
CONTACT: MICHAEL CURRENT
CONTRACTOR:
COLEMAN CUSTOM HOMES
PO BOX 4724
210 EDWARDS VILLAGE BLVD, STE. C105
EDWARDS, CO 81632
WWW.CCHVAIL.COM
PHONE: 970-855-0112
CONTACT: ALEX COLEMAN
INTERIOR DESIGN:
GRAYSON + CHRISTIE INTERIOR DESIGN
PO BOX 2259
EDWARDS, CO 81632
PHONE: 970-376-0458
CONTACT: OLIVIA GRAYSON
DRB
APPROVED
6/6/2017 12:00:00
AM