HomeMy WebLinkAboutA17-0033_FA000_1500647040.pdf 101044 z IS Z ow eft, y-FR.I 7„i► 7)-1110 4 9V r•, 4 •'' °�I��•yk• •'. Vail Fire&Emergency Se vices ..q�� .r' ,p9 07/21/17 frit }r p: OT, y ry A V �rJ'L3.71 � ir 6 LEGE\ 9 : Z 0 SYMBOL DEVICE MANUFACTURER/PART# MOUNTING a E 165 FOREST FACP Honeywell Vista-128BPT ° Ademco Vista 128 FACP Fire Alarm Control Panel w/7AH Batteries Mount on wall in manufacturer backbox w 0 Standby z Number of Current Total Current KP Device Type Devices (Amps) (Amps) LCD Keypad/Annunciator Honeywell 6160 Mount on wall in manufacturer backbox w Main FACP CPU 1 X 0.032 = 0.032 cr 4193SN Serial Interface 2 X 0.00015 = 0.0003 Combination Smoke & COSMOD4W Module 4 . X 0.052 = 0.208 Heat Detector w/Sounder System Sensor i3 series 4WTA—B 4” square box ZONE LIST i3 Smoke Detector 4 . X 0.0005 = 0.002 14 Smoke/CO Detector 9 X 0.0005 = 0.0045 Combination Smoke and ZONE # DESCRIPTION 6160 Keypad 2 X 0.04 = 0.08 ©co CO Detector w/Sounder System Sensor i4 series COSMO-4W 4" square box F- 1 SPRINKLER WATERFLOW SUM COLUMN FOR STANDBY LOAD 0.3268 = AMPS 0 2 SPRINKLER TAMPER 3 LEVEL 1 CO DETECTION Alarm Load ECosmo Interface Module COSMOD4W 4 LEVEL 1 SMOKE DETECTOR Number of Current Total Current 5 LEVEL 2 CO DETECTION O Z Device Type Devices (Amps) (Amps) KB 6 LEVEL 2 SMOKE DETECTOR Knox Box Main FACP CPU 1 X 0.032 = 0.032 7 LEVEL 3 CO DETECTION o 8 LEVEL 3 SMOKE DETECTOR 41935N Serial Interface 2 X 0.00015 = 0.0003 �, cv COSMOD4W Module 4 X 0.075 = 0.3 , ' co 9 LEVEL 4 CO DETECTION 0, Horn/Strobe, weatherproof System Sensor P2RK Weatherproof backbox o i3 Smoke Detector 4 X. 0.035 = 0.14 10 LEVEL 4 SMOKE DETECTOR o i4 Smoke/CO Detector 9 X 0-04 = 0.36 Q 11 SYSTEM TROUBLE 6160 Keypad 2 X 0.1 = 0.2 O Outside Horn/Strobe 1 X 0.195 = 0.195 . SUM COLUMN FOR ALARM LOADr. 1.2273 = AMPS 5 OU o Standby Load Required Standby Time in Hours L z `f' Current (Amps) • ,_ O o 0.3268 X 24 = 7.84 GENERAL NOTES: -I� ;, Q ° o Alarm Load Required Alarm Time in Hours o co 00 m rovecJ fcr i n s a Current {Amps} (15 MINUTES) 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ox 1.2273 X 0.25 = 0-31 ACCORDANCE WITH MANUFACTURER STANDARDS, FIRE Q) c m °° w U O co X Add Standby and Alarm Load for Required DEPARTMENT REQUIREMENTS AND NFPA 72. N ° I Ampere Hour Battery 8.15 2. REFER TO MANUFACTURERS DATA SHEETS AND X,, • Multiply by the Derating Factor of 1.2 INSTALLATION INSTRUCTIONS FOR FURTHER INFORMATION 0 o Total Ampere Hours Required = 9.78 0> Batteries Provided: I2AH Minimum REGARDING PRODUCT INSTALLATION, WIRING DIAGRAMS, Q :� PROGRAMMING AND DEVICE OPERATION. z F 1- 0 z 0 M N- SEQUE\CE OF oQ Q W OPERATIO\S: ‹ z(7) Z oz O m u) O O O cn O z0 E Z (n � 1- > 1- JI Q it (n N (n O O W D Z W W _ = O O O ZO Om ( W oZFQ D2DU CO LIp (n0 (/) (n0 O °� DEVICE Q Q D zO z0 z0 Q0 Q� DESCRIPTION 1 1 g o g o g o 10 I o: Q Q � � � F- � F- � Qo QO SMOKE DETECTOR X X X CARBON MONOXIDE DETECTOR X X X SPRINKLER WATERFLOW SWITCH X X X X SPRINKLER TAMPER SWITCH X X POWER LOSS, OPEN CIRCUIT, GROUND FAULT X X PROJECT \ FOVAT 0 \ : co 165 FOREST CY' CO VAIL COLOADO 1- 03 FRE ALAN SYSTEv D = 4—WIRE DATA/POWER, 4—#16AWG (2 PAIR) X = 2—WIRE DATA, 2—#16AWG EOL EOL AHJ: VAIL FIRE & EMERGENCY SERVICES p N-- 0 N = 2—WIRE SOUNDER CIRCUIT, 2—#18AWG LLI CL Z = 2—WIRE DATA CIRCUIT, 2—#16AWG D D FULLY SPRINKLERED C KP = KEYPAD CIRCUITING, 4—#18AWG FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. SYSTEM INCLUDES NEW 0 Ce W RISER NOTES: co co ADDRESSABLE VISTA 128 FIRE ALARM CONTROL PANEL. SMOKE Z Z DETECTORS WILL BE INSTALLED IN SLEEPING ROOMS AND AREAS OUTSIDE 0 Q 1 . REFER TO VISTA INSTALLATION MANUAL FOR D D OF SLEEPING ROOMS. INTEGRAL CARBON MONOXIDE DETECTORS ARE _ MORE INFORMATION. PROVIDED WITHIN 15' OF FUEL BURNING APPLIANCES. SOUNDERS ARE U C./)2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS MANUFACTURERS SPECIFICATIONS. L,N L,N [c INTEGRAL TO DETECTORS. A KNOX BOX WILL BE MOUNTED ON THE 3. VERIFY WIRING OF SYSTEM SENSOR COSMOD4W (TYP) (TYP) OUTSIDE OF THE HOME. THE SPRINKLER SYSTEM IS MONITORED BY THE W = J = PRIOR TO INSTALLATION. WIRING DIAGRAM IS FIRE ALARM SYSTEM. W INCLUDED SUBMITTAL BOOKS. _I O 120VAC DEDICATED POWER VISTA 128FPB Z D CO CONTROL PANEL FLOW SWITCH 0 = W Z TAMPER SWITCH < 0 I— 0 TELEPHONE LINE — FIRE O - TELEPHONE LINE — SECURITY \/WP 0 1 BELL N �O, EOLR FIRE PROTECTION ENGINEER: Q OUTPUT DEBORAH SHANER, P.E., S HAN ER LIFE SAFETY i_ ct O0 CO DATA/COM KP I I I PO BOX 1073, FRISCO, CO 80443 w 0 U 0 ISE IAG SAV OUTPUT (KEYPAD! !KEYPAD PHONE: 970-409-9082 FAX: 970-797- 1898 0 Z O U i_ O J Z (/) LQ O W U 0 SHEET DESCRIPTION: FIRE ALARM PLAN DRAWN BY: DATE: DLS 5/18/17 SHEET#: FA-0.00