HomeMy WebLinkAboutA17-0034_FA-0_1500647220.pdf a 0556 IFC2015 Occupancy Class - Residential multi- g100 BATTERY CALCULATIONS SYSTEM OUTPUTS family 907. 2. 11 . 2 Group R- 3. Single or Vail07/21F117&Emergencl Services CONTROL PANEL LOCATION: 1st Level Mechanical ANNUNCIATION NOTIFTC,lTION multiple station smoke alarms shall be HOURS OF SUPERVISION: 24 HOURS installed regardless of occupant load at PANEL: GE Concord 4 0 MINU ILS OF ALARM: 15 ItiIINC7ILS s all of the following locations: Device Device Total Total Po QTY PART NUMBER Standby Alarm Standby Alarm M H ° A 0 1 . On ceiling or wall outside each separate DESCRIPTION OF DEVICES Current Current Current Current o sleeping area . m U 1 - GE Concord l FACP 0.0000 0.0000 - 0.0000 0.0000 0 G Q 2. I n each room used for sleeping n :-d2 a) p g 2 ATP-1000 Annunciator 0.0120 0.1100 0.0240 0.22005 p c - o 1 60-758 4 output snapcard 0.0060 0.0400 0.0060 0.0400 g 0 - I z 3. I n each story within dwelling unit Property: o S4 d : i p 1 SYS COSMOD Lour Level Interface module +Detectors _ 0.0460 0.2030 0.0460 0.2030 1 -� i k ° . 1 SYS COSMOD Main Level Interface module +Detectors 0.0460 0.1810 0.0460 0.1810 Q a G 2 Larrieu 1 SYS COSMOD Upper level Interface module - Detectors 0.0460 0.2230 0.0460 0.2230 , o 2 .1 NFPA 72 2016 29 . 5. 1 . 1 Smoke alarms shall be installed: Residence ti , F 0 ° ) o a� 2 p 1 60-774 8 Zone Expansion Module 0.0380 0.2300 0.0380 0.2300 a, 5'. 3. 2 g , 5 [n Et 0 1 . In all sleeping rooms and guest rooms 1 ESL 26000 Carbon Monoxide Detector 0.0200 0.0400 0.0200 0.0400 ¢ c c 1~ w w U y y y N N N Al) N N N Al) N N N .te+ .E' .E' .E' U C a' 8 rt ,t 2. Outside of each sleeping area within 21 ft of door 1 SYS-I\l1W Interior Siren 0.0000 0.0750 0.0000 0.0750 P. P P. P. p g Address: 1 SYS-5603 135 degree fixed heat detector 0.0000 0.0000 0.0000 0.0000 Smoke or Heat Detector X X X X X 3. On every level , incIuding basements. 1875 W Gore Creek Dr. TOTAL: 0.226 1.212 Carbon Monoxide Detector X X X X x 4. In living areas o fguest suite Vail, CO 81657 STANDBY Ground Fault X X X X SUB-TOTAL: 0.23 AMP Open Circuit x X x x x Owner: 24 HOURS OF STANDBY: 24.00 HOURS LowBatery X X X X X _ NFPA 720 George & Silvia Larrieu SUB-TOTAL: 5.42 AMP HOURS AC Power Failure X X X X X 10426 S.W. 89th Place ALARM: Telephone Line Fault-daily timer test X x x 8. 4. 1 . 1 Carbon monoxide detectors shall be installed : Miami FL, 33176 SUB-TOTAL: 1.21 AMP Panel Silence Feature X 1 . Outside each sleeping area in immediate vicinity. General Contractor: 15 MINUTES OF ALARM: 0.25 HOURS Kienzle Construction SUB-TOTAL: 0.30 AMP HOURS 2. On every level PO BOX 941 TOTALS: Stamped approved. 3. Other location where required by law, code or standard. Eagle, CO 81631 970-343-2925 TOTAL SUPERVISORY: 5.42 AMP HOURS TOTAL ALARM: 0.30 AN'IP HOURS TOTAL: 5.73 AI\IPHOURS HB1091 Carbon monoxide detectors shall be installed IP *SPARE OF 20% 1.15 AlviiP HOURS Code Complience: MINIMUM BATTERY SIZE REQUIRED 6.87 ANIP HOURS within 15 feet of bedroom door and within 25 feet of a 2015 International Fire Code BATTERIES SUPPLTFD 7Ah A.i\IP HOURS f u e l fired appliance, fireplace, o r garage. 2016 NFPA-72 Nat. Fre c Alarm Code 2015 NFPA-70 Nat. Electrical Code BATTERY CALCULATIONS: MAIN ALARM CONTROL PANEL VAIL FIRE INSTALLATION STANDARDS (Rev 416 ) : Levels: Detection location and spacing shall be per latest NFPA72 3Levels Bldg Height: , 2015 IFC and as set forth : 18'1 Roof Height As this is an unsprinklered building, insurance company requires 1 . Installed i n a corridor not more than fifteen feet from a heat detector in the garage and mechanical. Occupancy Loads: the door of the farthest bedroom 2. Smokes req 'd in living rooms, family rooms, home Occupancy Rating: theaters and any rooms that may be used for sleeping . Residential - R-3 3. Detectors installed toward middle of room with Structure: consideration o f bathrooms, ceiling fans and air ducts. Type VB/Non-Rated/Non-Sprinkled © 0 ©Co 000 a t Upper Level 4 Kitchens and garages are not required to have heat Sq. Footage: detection . 4,599sgFt+ CO 5. Storage rooms, closets, unfinished crawl spaces not Communication Type: ANN g p DACT/POTS Lines ANN © o ®o (DCO Main Level required to have smoke detection . Primary Power Location: n135• 35° Carbon Monoxide detection required per latest NFPA72 and MainElecPanel - Breaker# L< 0:35` Colorado H B 10 91 . In addition : Submittal Prepared By: Exterior Horn/Strobe2 2 1 . CO to be instaled no further than 15 feet from furthest • © , © GE c o Cp Lower Level bedroom . a� SAE Concord 4 2. Within 20 feet of fuel fired appliances, including stoves, FACP Superior Alarm & Electronics PANEL gas, fire places, wood burning stoves or wood burning fire 210 Edwards Viii. Blvd. #A108 I I RISER DIAGRAM places. PH 970-926-8788 Phonelines (1) 120 VAC FX 970-926-8790 Dedicated 3. Entrance vestibules from attached garages. brad@superioralarmco.com Ba8 AH Batttt Backup 4. Areas with gas fired appliances that pose safety risk. MONITORING Syster-n Coce eference API - DENVER COLORADOREMOTE STATION SYMBOL DESCRIPTION SYS# 6101-1759 NATIONAL INSTITUTE FOR CERTIFICATION FACP FIRE ALARM CONTROL PANEL OARM ADDRESSABLE RELAY MODULE IN ENGINEERING TECHNOLOGIES Fire Protection Engineering Technology SMOKE DETECTOR (PHOTOELECTRIC) HORN/SOUNDER Fire Alarm Systems DESCIPTIO\ CLASS STYLE TYPE 0135' HEAT DETECTOR FIXED/ROR (TEMP LISTED) IY�I1 HORN WITH STROBE F 15 (NUMBER INDICATES CANDELA) A significant remodel of an existing single family residence is taking NOTIFICATION APPLIANCE CIRCUIT 4 #18 AWG FPL ANN ANNUNCIATOR �5 AC POWER B Y 4 #18 AWG FPL STROBE (NUMBER place in the Town of Vail . The residence will not be s p r i n k l e re d . INITIATING DEVICE CIRCUITS 4 #18 AWG FPL tZi WATER FLOW SWITCH INDICATES CANDELA) Matt Madden We will install smoke and carbon monoxide combination devices in ANNUNCIATOR CIRCUITS B 4 #18 AWG FPLEOL RE END OF LINE RESISTOR NICET #134111 Level III f r VALVE WITH TAMPER SWITCH Valid Thru 05/1/18 applicable locations and system will be zoned by floor. Our OAIM INPUT MODULE k FIRE DEPARTMENT "KNOX" BOX ORIG.7/13/17 SCALE: 1/8"=1'0" installation will meet Town o f Vail Standards and applicable codes. USE PLENUM RATED WIRE IN ALL PLENUM SPACES AIM C0 MONITORED CARBON MONOXIDE DETECTOR REV. DATE NOTES: / / 0 WRE CHART ®CO SMOKE/CARBON MONOXIDE COMBO DETECTOR �1\ Scope of Work A LEGEND FINAL INSP. ) AS BUILTS: AHJ: Vail Fire Department Mike Vaughan, Fire Marshal Permit #: PAGE NAME: Title/Bldg/Calcs/Map AHJ : Vail Fire Department - Fire Marshal Mike Vaughan 970-479-2252 A 0 SHEET 1 OF 4 J