Loading...
HomeMy WebLinkAboutDRB17-0212_A1.0_1498755420.pdf10' EASEMENT (PER RECORD PLAT) 8016.4 8021.3 8026.4 8031.3 PHONE PEDESTAL SEWER MANHOLE RIM ELEV. = 8017.8' CONCRETE PAN WOOD FENCE FOUND BLUE PLASTIC CAP ON A REBAR, LS No. ILLEGIBLE (ELEV. = 8006.9') NORTHEASTERLY CORNER OF LOT 7 FOUND ALUMINUM CAP ON A REBAR, LS No. 23089 LOT 5 LOT 4 LOT 3 GENEVA DRIVE (50' R.O.W.) VAIL VILLAGE WEST FILING No. 1 S88°55'24"E - 168.55' N01°04'36"E - 104.10' S88°55'24"E - 168.55' N01°04'36"E - 104.10' 8006 8 0 0 8 8 0 12 8014 8016 8018 8022 8024 8026 8028 8028 8026 8024 8022 8018 8016 8014 8012 8008 8006 8004 8004 8 010 8020 8030 8020 8010 S PH MAGNETIC 28.3' 28.5' 28.3' 28.5' 10' EASEMENT (PER RECORD PLAT) 8016.4 8021.3 8026.4 8031.3 PHONE PEDESTAL NHOLE = 8017.8' CONCRETE PAN WOOD FENCE FOUND BLUE PLASTIC CAP ON A REBAR, LS No. ILLEGIBLE (ELEV. = 8006.9') WOOD DECK WOOD DECK WOOD STEPS EDGE OF CONCRETE WALKWAY INDICATES AN EVERGREEN TREE INDICATES A DECIDUOUS TREE SINGLE FAMILY RESIDENCE 0.4028 ACRES 1709 GENEVA DRIVE 36"W - 208.20' LOT 5 LOT 4 VAIL VILLAGE WEST FILING No. 1 S88°55'24"E - 168.55' N01°04'36"E - 104.10' S88°55'24"E - 168.55' N01°04'36"E - 104.10' 8006 8 0 0 8 8 0 1 2 8014 8016 8018 8022 8024 8026 8028 8028 8026 8024 8022 8018 8016 8014 8012 8008 8006 8004 8004 8 0 10 8020 8030 8020 8010S PH 10' EASEMENT (PER RECORD PLAT) 8016.4 8021.3 8026.4 8031.3 LOT 5 LOT 4 LOT 3 GENEVA DRIVE (50' R.O.W.) VAIL VILLAGE WEST FILING No. 1 S88°55'24"E - 168.55' N01°04'36"E - 104.10' S88°55'24"E - 168.55' N01°04'36"E - 104.10' 8006 8 0 0 8 8 0 12 8014 8016 8018 8022 8024 8026 8028 8028 8026 8024 8022 8018 8016 8014 8012 8008 8006 8004 8004 8 0 10 8020 8030 8020 8010 MAGNETIC 18 19 17 16 15 13 14 13 12 11 10 ENTRY SNOW STORAGE AREA = 600 SQ. FT. 24 (8%) (10%) (10%) (10%) (5%) LOWER LEVEL (BASEMENT) 8013'-10 1/4" (-10'-7 3/4") MAIN LEVEL 8024'-6" (0'-0") UPPER LEVEL 8034'-7 3/4" (10'-1 3/4") LOWER LEVEL (BASEMENT) 8007'-4 1/4" (-17'-1 3/4") MAIN LEVEL 8018'-6" (-6'-0") UPPER LEVEL 8028'-7 3/4" (4'-1 3/4") 11 (10%) 12 UNIT B - SECONDARY UNIT (EAST SIDE) UNIT A - PRIMARY UNIT (WEST SIDE) (4%) (6%) (10%) (5%) (5%) (6%) (6%) GARAGE 8013'-4 1/4" GARAGE 8012'-10 1/4" 8010' - 4" 8006' - 10 1/4" 8015' - 0" 8023' - 6" 8023' - 5" ENTRY2" / 12" 2" / 12" 1 1/2" / 12" 2" / 12"1 1/2" / 12" 2" / 12" 2" / 12" SNOW STORAGE AREA = 300 SQ. FT. CONCRETE DRIVEWAY 3,000 SQ. FT. (UNHEATED) REQUIRES 900 SQ. FT. OF SNOW STORAGE RIDGE 8018 8020 8022 8016 8014 8012 8010 8008 9X18 CAR 9X18 CAR 9X18 CAR 9X19 CAR 9X18 CAR 9X18 CAR 9X19 CAR 9X19 CAR CONCRETE PATIO 450 S.F. CONCRETE PATIO 300 S.F. CONC. WALK ON-GRADE STEPS W/ HANDRAIL CONC. WALK CONC. WALK 12" GRAVEL DRAINAGE SWALE ALONG TOP RIM OF BOULDER WALLS 2' HEIGHT BOULDER RETAINING WALL B.O.W. = 8012'-0" T.O.W. = 8014'-0" 2' HEIGHT BOULDER RETAINING WALL B.O.W. = 8014'-0" T.O.W. = 8016'-0" 2' HEIGHT BOULDER RETAINING WALL B.O.W. = 8010'-0" T.O.W. = 8012'-0" 2' - 0" NO WALLS WITHIN 24" OF PROPERTY LINE EXISTING CONC. PAN MEETS T.O.VAIL ENGINEERING STANDARDS HEATED DRIVEWAY NOTE: PROVIDE SEPERATE HEAT ZONE TO PAVEMENT AREAS WITHIN T.O.VAIL PROPERTY MARKED TOV OR ROW AT CONTROL BOX. SPECIAL INSPECTIONS NOTE: THE GENERAL CONTRACTOR MUST SCHEDULE SPECIAL INSPECTIONS WITH THE GEOTECHNICAL ENGINEER AS DESCRIBED IN THE SOILS INVESTIGATION REPORT T.O.VAIL SITE PLAN NOTES: 1. NO RETAINING WALLS WITHIN 24" OF PROPERTY LINES. 2. 8% MAX SLOPE FROM EDGE OF ROADWAY FOR FIRST 10 FT. 3. ALL RETAINING WALLS OVER 4'-0" HEIGHT SHALL BE DESIGNED AND STAMPED BY A PROFESSIONAL ENGINEER. 5. UTILITY SCARS TO BE RE-GRADED TO NATURAL GRADE AND RE-SEEDED W/ NATURAL VEGETATION. 6. NO FINISH GRADES BETWEEN RETAINING WALLS TO EXCEED 2:1 SLOPE. LIMITS OF DISTURBANCE FENCE: USE EROSION CONTROL SILT FENCE ON DOWNHILL PORTION OF LOT 8038' - 8 1/4" RIDGE RIDGE 8044' - 0 1/4" RIDGE 8037' - 3 3/8" RIDGE 8040' - 0 1/2" 8038' - 4 7/8" 8031' - 2 7/8" 8032' - 8 7/8" 8034' - 9 1/4" ABOVE GRADE DECK ABOVE GRADE DECK LOT SPLIT LINE LOT SPLIT LINE 20' - 0" 15' - 0" 10' - 0" 15' - 0" 10' - 0" 15' - 0" 10' - 0" EASEMENT SETBACK SETBACK EASEMENT SETBACK EASEMENT FRONT YARD SETBACK EXISTING TREES TO REMAIN 2' HEIGHT BOULDER RETAINING WALL B.O.W. = 8018'-0" T.O.W. = 8020'-0" 2' HEIGHT BOULDER RETAINING WALL B.O.W. = 8020'-0" T.O.W. = 8022'-0" FOUNDATION DRAIN TERMINATION AT LOWER GRADES TO DAYLIGHT OR UNDERGROUND GRAVEL PERCOLATION DRAIN 8042' - 1 3/4" 8043' - 5 3/4" 8048' - 0 1/8" 8048' - 8 1/4" OVERHEAD ELECTRICAL LINE TO REMAIN OVERHEAD ELECTRICAL LINE TO BE BURIED ELECTRICAL POLE TO REMAIN OVERHEAD ELECTRICAL LINE TO BE RE-ROUTED OVERHEAD ELECTRICAL LINE TO REMAIN G G G G G G G G G G G G G G G G G G G G E E E E E E E E E PH PH PH PH PH PH PH PH PH PH PH PH PH PH PH PH W W MECH. ROOM MECH. ROOM W W W W W W W W W W W W W W W W W W SS S S S S S S S S S S S S S S S S S S CONTRACTOR TO VERIFY LOCATION OF WATER CONNECTION CONTRACTOR TO VERIFY LOCATION OF GAS CONNECTION GAS METER UNDER W.P. DECK BOTH ELECTRICAL METER BOXES IN CLOSETS ON WALL GAS METER UNDER W.P. ENTRY DECK ELECTRICAL LINE BURIED PNONE AND CABLE LINE BURIED 0' 4' 8' 16' 32' NORTH ENTRY 24 22 SINGLE-FAMILY HOUSE TO BE COMPLETELY DEMOLISHED LIMITS OF DISTURBANCE FENCE: USE EROSION CONTROL SILT FENCE ON DOWNHILL PORTION OF LOT OUTLINE OF PROPOSED DUPLEX RESIDENCE OVERHEAD ELECTRICAL LINE TO REMAIN OVERHEAD ELECTRICAL LINE TO BE BURIED ELECTRICAL POLE TO REMAIN OVERHEAD ELECTRICAL LINE TO BE RE-ROUTED OVERHEAD ELECTRICAL LINE TO REMAIN 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date Consultant Address Address Phone Fax e-mail REVISIONS 5/30/2017 11:29:40 AM A1.0 SITE PLAN 1719 1709 GENEVA DUPLEX DRB SUBMITTAL 5-26-17 5-30-17 DAVE HILB 1709 GENEVA DRIVE, VAIL, CO MATTERHORN VILLAGE FILING 1, LOT 4 No. Description Date 1" = 10'-0" 1 SITE PLAN 1" = 20'-0" 2 SITE PLAN DEMO 1" = 20'-0" 3 Site Plan TRUE NORTH' LIGHTING LEGEND COUNT: (6) WALL SCONCE LIGHT FIXTURES. HINKLEY "SHELTER" 1326 OUTDOOR WALL LIGHT SIZE: 4.5" W x 15.5" H x 4.8" D EXTERIOR LIGHTS ALLOWED 1 PER 1,000 S.F. OF LOT AREA = 17 FIXTURES EXTERIOR LIGHTS PROPOSED = 15 FIXTURES LOT AREA (.538 ACRES) = 17,546 S.F. RECESSED CAN CEILING LIGHT FOR EXTERIOR USE SELECTION BY OWNER/CONTRACTOR SIZE: TO BE DETERMINED COUNT: (9) RECESSED CAN LIGHT FIXTURES. SYMBOL A SYMBOL C SYMBOL B LED RECESSED WALL LIGHT OUTDOOR WATERPROOF 1P54 MODERN WALL LAMP - FOR EXTERIOR USE SIZE: 125mm W x 225 mm H x 85mm D COUNT: (5) NEAR GROUND, DOES NOT COUNT TOWARDS MAX. RECESSED CAN LIGHT FIXTURES. A A A A A A B B B B B B B B C C C C C B 22' 19.8' 23' 36' 3' to wall 2' to wall 31' height DRB APPROVED 6/21/2017 12:00:00 AMImprovements within existing easments must be approved by easement benefactor. Are these Utility Easments? Then Utilities must approve improvements. Electric service lines should be buried as shown. Adjacent property service line should be placed within a private easment for adjacent property owner.