HomeMy WebLinkAboutDRB17-0226_A108_1497992280.pdf---
APT BATH
---
MECH
---
MEDIA ROOM
NEW
+42", VFY
TV
A-24
A-24
A-24
A-24
A
A
A
A
A
A
A
A
A
A
A
A
D D
A
TO EXTG
HALL
LIGHTS
DROPPED WOOD
BOX BEAMS
A-48
MOTION
SWITCH
EXTERIOR LANDSCAPE LIGHT A
LIGHTING SYMBOLS
BATHROOM EXHAUST FAN
TV 2 RG6 COAXIAL
s
DUPLEX OUTLET, +3" U.O.N.
SWITCH
DIMMER
MULTIPLE SWITCH
3-WAY SWITCH
RECESSED LENSED SHOWER LIGHT
QUAD OUTLET
GENERAL ELECTRICAL NOTES:
1. POWER AND ELECTRICAL DISTRIBUTION
TO BE IN ACCORDANCE WITH IRC & ICC
ELECTRICAL CODE
2. PER 2009 IECC: A MINIMUM OF 50% OF
LIGHTING TO BE HIGH EFFICACY
3. TYPICAL COLOR OF OUTLETS, SWITCHES,
AND COVERS (LUTRON ARCHITECTURAL
MATTE):
ALMOND (AL) - DRYWALL LOCATIONS
BROWN (BR) - STONE & NATURAL WOOD
LOCATIONS, VFY.
4. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
5. VERIFY ALL FLOOR OUTLET LOCATIONS
WITH FINAL FURNITURE LAYOUTS
6. VERIFY HEIGHTS OF RECEPTACLES FOR
TVs WITH INTERIOR ELEVATIONS
7. ALL EXISTING OUTLETS TO REMAIN,
MODIFICATIONS AS SHOWN ON PLANS
8. ALL ELEC. DIMS ARE APPROXIMATE AND
SHOULD BE VERIFIED. MOST LIGHTS ARE
INTENDED TO BE CENTERED OR
GROUPED AROUND THE CENTER OF THE
SPACE THAT THEY ILLUMINATE, ASK
ARCHITECT ABOUT CONFLICTS WITH
DIMS.
9. TYPICAL SWITCH HEIGHTS: 48" AFF TO
THE TOP OF SWITCH BOX FOR STANDARD
SWITCHES, +42" AFF FOR BESIDE
SWITCHES
10. EXISTING ELECTRICAL TO REMAIN
SHOWN IN LIGHT GREY
3
4
D
F
24" LED UNDER CABINET LIGHT
HOMEWORKS KEY PAD
HOMEWORKS CIRCUIT DESIGNATION
01
COMBO. DATA/TELEPHONE OUTLET
NEW NATURAL GAS LINE
DUPLEX FLOOR OUTLET
INFLOOR DATA AND QUAD
POWER OUTLET
INFLOOR DATA AND DUPLEX
POWER OUTLET
DUPLEX OUTLET, HALF
SWITCHED +18" U.O.N.
SWITCH IN JAMB
J
HB
HOSE BIB
A
A
EXTERIOR WALL SCONCE
EXTERIOR STEP LIGHT
NEW JUNCTION BOX
J
L
RECESSED CAN LIGHT:
ADJUSTABLE &/OR SLOPED TRIM
FIXED DOWN LIGHT
RECESSED CAN LIGHT:
SURFACE MOUNTED LIGHT FIXTURE
A
GROUND FAULT DUPLEX OUTLET,
+42" U.O.N.
KEY
A-24
PENDANT LIGHT
A
F
H
BATHROOM EXHAUST FAN
WITH HEATER
COMBINATION SMOKE AND
CARBON MONOXIDE DETECTOR
DUPLEX FLOOR OUTLET, HALF
SWITCHED
A
CEILING MOUNTED LIGHT FIXTURE
A108
RCP
P R O J E C T :
P I T K I N R E S I D E N C E
D R A W N B Y :
D A T E :
R E V I S I O N S :
95 FOREST
ROAD
VAIL, COLORADO
06.01.17
-
PIT17
1
1/4" = 1'-0"
PROPOSED LEVEL TWO REFLECTED CEILING PLAN
DRB
APPROVED
12/2/2017 8:43:40
AM