Loading...
HomeMy WebLinkAboutDRB17-0226_M1_1497992280.pdfRoom Checksums By BG Buildingworks 1 - Bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 36.78 22 Infiltration -146 -146 6 21 6 22 0 0 MinStop/Rh 36.78 22 Sub Total ==> -146 -146 6 21 6 22 0 21 Return 21 Internal Loads 2 2 Exhaust 273 Lights 0.00 0 0 80 273 75 273 0 0 0 Rm Exh 70 People 0.00 0 14 49 19 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 343 Sub Total ==> 0.00 0 0 94 322 94 343 0 0 Ceiling Load 0.00 0 -2 0 0 0 0 0 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.48 0.48 cfm/ft² 0 Ov/Undr Sizing 62.25 -247 -247 0 0 0 0 632.99 cfm/ton Exhaust Heat -0.05 0 0 0 1,314.75 ft²/ton -9.92 9.13 Btu/hr·ft² 0.2 No. People 365 Grand Total ==> 100.00 -397 -395 100.00 343 100.00 365 0 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 40 Main Htg -0.4 19 71.9 95.0 0.0 0.4 0.3 19 75.0 59.0 67.7 55.0 51.6 65.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.4 Total Opt Vent 0.0 0.0 0.0 0 -0.4 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -4 0 0 0.00 1.02 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 2 2 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 19 19 19 0 0 0 0 0 19 19 19 0 0 0 0 0 0 70 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 1 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Dining room HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 9 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 242 Glass Solar 0 0 13 627 4 242 0 161 Glass/Door Cond -1,217 21.58 -1,217 -1 -61 3 161 0 AIRFLOWS Heating Cooling 31 Wall Cond 3.15 -178 -142 0 9 1 38 8 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 13.14 63 Infiltration -741 -741 -1 -25 1 63 0 0 MinStop/Rh 37.87 496 Sub Total ==> -2,135 -2,099 11 549 8 504 8 283 Return 283 Internal Loads 9 9 Exhaust 1,386 Lights 0.00 0 0 28 1,386 23 1,386 0 0 0 Rm Exh 4,200 People 0.00 0 60 2,940 69 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 5,586 Sub Total ==> 0.00 0 0 89 4,326 92 5,586 0 2 Ceiling Load 0.00 0 -8 0 1 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 1.35 1.35 cfm/ft² 0 Ov/Undr Sizing 62.07 -3,499 -3,499 0 0 0 0 539.01 cfm/ton Exhaust Heat -0.02 1 0 0 400.04 ft²/ton -27.77 30.00 Btu/hr·ft² 12.0 No. People 6,084 Grand Total ==> 100.00 -5,638 -5,606 100.00 4,875 100.00 6,089 6 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 203 Main Htg -5.6 274 71.9 95.0 0.5 6.1 4.9 274 75.0 60.9 77.3 55.0 52.5 69.6 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 83 42 51 Humidif 0.0 0 0.0 0.0 0.5 6.1 Total Opt Vent 0.0 0.0 0.0 0 -5.6 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -5 0 0 0.00 0.08 0.00 0.00 0 Supply Air Leakage 72 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 9 9 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 274 274 274 0 0 0 0 0 274 274 274 0 0 0 0 0 0 4,200 0 Int Door 0 Ext Door 0 0 0 59.1/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 2 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Entry HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 10 Mo/Hr: 7 / 10 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 75 / 57 / 55 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 4,204 Glass Solar 0 0 66 4,204 60 4,204 0 -49 Glass/Door Cond -2,728 37.02 -2,728 -1 -49 -1 -49 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 2.59 -191 -191 0 0 0 Sec Fan 5.55 -39 Infiltration -409 -409 0 1 -1 -39 0 0 MinStop/Rh 45.16 4,117 Sub Total ==> -3,328 -3,328 65 4,156 59 4,117 0 364 Return 364 Internal Loads 5 5 Exhaust 765 Lights 0.00 0 0 12 765 11 765 0 0 0 Rm Exh 2,100 People 0.00 0 23 1,470 30 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 2,865 Sub Total ==> 0.00 0 0 35 2,235 41 2,865 0 0 Ceiling Load 0.00 0 -2 0 0 0 0 0 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 3.20 3.20 cfm/ft² 0 Ov/Undr Sizing 54.55 -4,020 -4,020 0 0 0 0 616.34 cfm/ton Exhaust Heat 0.00 0 0 0 192.52 ft²/ton -65.80 62.33 Btu/hr·ft² 6.0 No. People 6,981 Grand Total ==> 100.00 -7,369 -7,350 100.00 6,391 100.00 6,981 0 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 112 Main Htg -7.4 359 71.9 95.0 0.6 7.0 6.4 359 75.0 59.4 69.6 55.0 51.8 66.6 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 21 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 195 195 100 Humidif 0.0 0 0.0 0.0 0.6 7.0 Total Opt Vent 0.0 0.0 0.0 0 -7.4 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -22 0 0 0.00 0.30 0.00 0.00 0 Supply Air Leakage 75 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 5 5 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 359 359 359 0 0 0 0 0 359 359 359 0 0 0 0 0 0 2,100 0 Int Door 0 Ext Door 0 0 0 53.6/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 3 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Hall HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 36.78 44 Infiltration -292 -292 6 42 6 44 0 0 MinStop/Rh 36.78 44 Sub Total ==> -292 -292 6 42 6 44 0 42 Return 42 Internal Loads 4 4 Exhaust 546 Lights 0.00 0 0 80 546 75 546 0 0 0 Rm Exh 140 People 0.00 0 14 98 19 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 686 Sub Total ==> 0.00 0 0 94 644 94 686 0 1 Ceiling Load 0.00 0 -3 0 1 0 0 -1 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.48 0.48 cfm/ft² 0 Ov/Undr Sizing 62.25 -494 -494 0 0 0 0 632.99 cfm/ton Exhaust Heat -0.05 0 0 0 1,314.77 ft²/ton -9.92 9.13 Btu/hr·ft² 0.4 No. People 731 Grand Total ==> 100.00 -794 -789 100.00 687 100.00 730 -1 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 80 Main Htg -0.8 39 71.9 95.0 0.1 0.7 0.7 39 75.0 59.0 67.7 55.0 51.6 65.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.7 Total Opt Vent 0.0 0.0 0.0 0 -0.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -8 0 0 0.00 1.02 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 4 4 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 39 39 39 0 0 0 0 0 39 39 39 0 0 0 0 0 0 140 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 4 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Kitchen HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 9 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 276 Glass Solar 0 0 21 714 7 276 0 183 Glass/Door Cond -1,386 34.83 -1,386 -2 -70 5 183 0 AIRFLOWS Heating Cooling 27 Wall Cond 4.07 -162 -125 0 8 1 35 8 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 15.41 82 Infiltration -613 -613 -1 -21 2 82 0 0 MinStop/Rh 54.30 568 Sub Total ==> -2,161 -2,124 18 631 15 576 8 201 Return 201 Internal Loads 8 8 Exhaust 1,147 Lights 0.00 0 0 33 1,147 30 1,147 0 0 0 Rm Exh 1,400 People 0.00 0 28 980 37 0 0 Auxiliary 683 Misc 0.00 0 0 20 683 18 683 0 3,229 Sub Total ==> 0.00 0 0 82 2,809 85 3,229 0 1 Ceiling Load 0.00 0 -7 0 0 0 0 -1 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 1.15 1.15 cfm/ft² 0 Ov/Undr Sizing 45.90 -1,826 -1,826 0 0 0 0 608.71 cfm/ton Exhaust Heat -0.02 1 0 0 529.76 ft²/ton -23.68 22.65 Btu/hr·ft² 4.0 No. People 3,799 Grand Total ==> 100.00 -3,979 -3,957 100.00 3,441 100.00 3,806 6 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 168 Main Htg -4.0 193 71.9 95.0 0.3 3.8 3.4 193 75.0 59.5 70.1 55.0 51.9 66.8 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 86 48 56 Humidif 0.0 0 0.0 0.0 0.3 3.8 Total Opt Vent 0.0 0.0 0.0 0 -4.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 7 0 0 0.00 -0.18 0.00 0.00 0 Supply Air Leakage 72 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 8 8 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 193 193 193 0 0 0 0 0 193 193 193 0 0 0 0 0 0 1,400 0 Int Door 0 Ext Door 0 0 0 23.8/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 5 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Laundry HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 36.78 36 Infiltration -237 -237 6 34 6 36 0 0 MinStop/Rh 36.78 36 Sub Total ==> -237 -237 6 34 6 36 0 34 Return 34 Internal Loads 3 3 Exhaust 444 Lights 0.00 0 0 80 444 75 444 0 0 0 Rm Exh 114 People 0.00 0 14 80 19 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 557 Sub Total ==> 0.00 0 0 94 523 94 557 0 1 Ceiling Load 0.00 0 -3 0 1 0 0 -1 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.48 0.48 cfm/ft² 0 Ov/Undr Sizing 62.25 -402 -402 0 0 0 0 632.99 cfm/ton Exhaust Heat -0.05 0 0 0 1,314.77 ft²/ton -9.92 9.13 Btu/hr·ft² 0.3 No. People 594 Grand Total ==> 100.00 -645 -641 100.00 558 100.00 593 -1 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 65 Main Htg -0.7 31 71.9 95.0 0.1 0.6 0.6 31 75.0 59.0 67.7 55.0 51.6 65.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.6 Total Opt Vent 0.0 0.0 0.0 0 -0.7 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -7 0 0 0.00 1.02 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 3 3 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 31 31 31 0 0 0 0 0 31 31 31 0 0 0 0 0 0 114 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 6 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Living room HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 11 / 14 Mo/Hr: 11 / 14 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 37 / 31 / 22 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 8,290 Glass Solar 0 0 70 8,290 67 8,290 0 -1,352 Glass/Door Cond -3,239 23.76 -3,239 -11 -1,352 -11 -1,352 0 AIRFLOWS Heating Cooling 24 Wall Cond 1.43 -195 -127 0 24 0 37 13 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 1.17 -159 -159 0 0 0 Sec Fan 12.18 -1,209 Infiltration -1,661 -1,661 -6 -697 -10 -1,209 0 0 MinStop/Rh 38.54 5,754 Sub Total ==> -5,254 -5,186 53 6,266 47 5,767 13 684 Return 684 Internal Loads 20 20 Exhaust 3,106 Lights 0.00 0 0 26 3,106 25 3,106 0 0 0 Rm Exh 3,500 People 0.00 0 21 2,450 28 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 6,606 Sub Total ==> 0.00 0 0 47 5,556 53 6,606 0 2 Ceiling Load 0.00 0 -9 0 2 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 1.46 1.46 cfm/ft² 0 Ov/Undr Sizing 61.63 -8,402 -8,402 0 0 0 0 643.35 cfm/ton Exhaust Heat -0.01 1 0 0 441.30 ft²/ton -29.96 27.19 Btu/hr·ft² 10.0 No. People 12,361 Grand Total ==> 100.00 -13,633 -13,596 100.00 11,823 100.00 12,373 11 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 455 Main Htg -13.6 663 71.9 95.0 1.0 12.4 11.8 663 75.0 58.9 67.0 55.0 51.6 65.5 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 18 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 158 113 71 Humidif 0.0 0 0.0 0.0 1.0 12.4 Total Opt Vent 0.0 0.0 0.0 0 -13.6 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 22 0 0 0.00 -0.16 0.00 0.00 0 Supply Air Leakage 37 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 20 20 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 663 663 663 0 0 0 0 0 663 663 663 0 0 0 0 0 0 3,500 0 Int Door 0 Ext Door 0 0 0 22.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 7 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 1 - Spare HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 9 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.9 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 127 Glass Solar 0 0 37 328 14 127 0 84 Glass/Door Cond -637 61.87 -637 -4 -32 9 84 0 AIRFLOWS Heating Cooling 29 Wall Cond 15.30 -158 -132 1 8 4 34 5 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 24.45 47 Infiltration -252 -252 -1 -9 5 47 0 0 MinStop/Rh 101.63 287 Sub Total ==> -1,046 -1,021 33 296 32 292 5 53 Return 53 Internal Loads 3 3 Exhaust 471 Lights 0.00 0 0 53 471 51 471 0 0 0 Rm Exh 121 People 0.00 0 9 85 13 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 592 Sub Total ==> 0.00 0 0 62 556 64 592 0 1 Ceiling Load 0.00 0 -3 0 0 0 0 -1 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.72 0.72 cfm/ft² 39 Ov/Undr Sizing 0.00 0 0 4 39 4 39 649.69 cfm/ton Exhaust Heat -0.03 0 0 0 897.36 ft²/ton -14.92 13.37 Btu/hr·ft² 0.3 No. People 918 Grand Total ==> 100.00 -1,030 -1,024 100.00 890 100.00 923 5 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 69 Main Htg -1.0 50 71.9 95.0 0.1 0.9 0.9 50 75.0 58.0 62.5 55.0 50.6 61.4 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 59 22 38 Humidif 0.0 0 0.0 0.0 0.1 0.9 Total Opt Vent 0.0 0.0 0.0 0 -1.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 16 0 0 0.00 -1.59 0.00 0.00 0 Supply Air Leakage 72 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 3 3 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 50 50 50 0 0 0 0 0 50 50 50 0 0 0 0 0 0 121 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 8 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - East bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 76.1 69.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 76.1 69.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 69.7 76.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 17.86 -109 0 0 0 13 71 71 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 32.40 30 Infiltration -197 -197 6 28 5 30 0 0 MinStop/Rh 50.26 30 Sub Total ==> -306 -197 6 28 18 101 71 29 Return 29 Internal Loads 2 2 Exhaust 369 Lights 0.00 0 0 77 369 66 369 0 0 0 Rm Exh 95 People 0.00 0 14 66 17 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 463 Sub Total ==> 0.00 0 0 90 435 82 463 0 19 Ceiling Load 0.00 0 -39 4 19 0 0 -19 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.50 0.50 cfm/ft² 0 Ov/Undr Sizing 52.31 -318 -318 0 0 0 0 577.53 cfm/ton Exhaust Heat -0.80 5 0 -2 1,153.86 ft²/ton -11.27 10.40 Btu/hr·ft² 0.3 No. People 512 Grand Total ==> 100.00 -608 -554 100.00 482 100.00 562 50 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 54 Main Htg -0.6 27 69.7 95.0 0.1 0.6 0.5 27 76.1 59.3 67.5 55.0 51.2 64.0 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 60 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.6 Total Opt Vent 0.0 0.0 0.0 0 -0.6 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 11 0 0 0.00 -1.77 0.00 0.00 -2 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 2 2 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 27 27 27 0 0 0 0 0 27 27 27 0 0 0 0 0 0 95 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 9 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - East bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 76.1 69.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 76.1 69.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 69.7 76.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 11.90 -362 0 0 0 6 175 175 0.00 293 Glass Solar 0 0 12 293 11 293 0 195 Glass/Door Cond -1,472 48.37 -1,472 8 195 7 195 0 AIRFLOWS Heating Cooling 47 Wall Cond 8.70 -265 -217 2 47 2 57 10 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 21.58 93 Infiltration -657 -657 4 94 3 93 0 0 MinStop/Rh 90.55 627 Sub Total ==> -2,756 -2,346 26 628 30 812 185 143 Return 143 Internal Loads 8 8 Exhaust 1,229 Lights 0.00 0 0 51 1,229 45 1,229 0 0 0 Rm Exh 700 People 0.00 0 20 490 26 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,929 Sub Total ==> 0.00 0 0 71 1,719 71 1,929 0 63 Ceiling Load 0.00 0 -129 3 63 0 0 -63 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.75 0.75 cfm/ft² 0 Ov/Undr Sizing 9.74 -296 -296 0 0 0 0 593.72 cfm/ton Exhaust Heat -0.54 16 0 -8 790.41 ft²/ton -16.91 15.18 Btu/hr·ft² 2.0 No. People 2,619 Grand Total ==> 100.00 -3,044 -2,771 100.00 2,410 100.00 2,733 114 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 180 Main Htg -3.0 135 69.7 95.0 0.2 2.7 2.5 135 76.1 59.6 69.2 55.0 51.8 66.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 200 0 0 Wall 113 51 45 Humidif 0.0 0 0.0 0.0 0.2 2.7 Total Opt Vent 0.0 0.0 0.0 0 -3.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -7 0 0 0.00 0.24 0.00 0.00 -8 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 8 8 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 135 135 135 0 0 0 0 0 135 135 135 0 0 0 0 0 0 700 0 Int Door 0 Ext Door 0 0 0 11.1/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 10 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - Kitchen HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.7 70.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.7 70.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 70.9 75.7 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 12.51 -138 0 0 0 8 89 89 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 18.57 18 Infiltration -204 -204 3 29 2 18 0 0 MinStop/Rh 31.08 18 Sub Total ==> -342 -204 3 29 9 107 89 54 Return 54 Internal Loads 3 3 Exhaust 382 Lights 0.00 0 0 42 382 32 382 0 0 0 Rm Exh 700 People 0.00 0 54 490 59 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,082 Sub Total ==> 0.00 0 0 96 872 91 1,082 0 12 Ceiling Load 0.00 0 -19 1 12 0 0 -12 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.91 0.91 cfm/ft² 0 Ov/Undr Sizing 75.10 -826 -826 0 0 0 0 517.41 cfm/ton Exhaust Heat -0.22 2 0 -1 565.53 ft²/ton -19.65 21.22 Btu/hr·ft² 2.0 No. People 1,112 Grand Total ==> 100.00 -1,100 -1,050 100.00 913 100.00 1,188 76 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 56 Main Htg -1.1 51 70.9 95.0 0.1 1.2 1.0 51 75.7 61.0 76.6 55.0 52.2 68.2 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 75 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 1.2 Total Opt Vent 0.0 0.0 0.0 0 -1.1 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 65 0 0 0.00 -5.95 0.00 0.00 -1 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 3 3 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 51 51 51 0 0 0 0 0 51 51 51 0 0 0 0 0 0 700 0 Int Door 0 Ext Door 0 0 0 35.7/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 11 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - Laundry/hall HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.7 70.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.7 70.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 70.9 75.7 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 19.43 -239 0 0 0 13 155 155 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 34.49 64 Infiltration -423 -423 6 60 5 64 0 0 MinStop/Rh 53.92 64 Sub Total ==> -662 -423 6 60 18 219 155 62 Return 62 Internal Loads 5 5 Exhaust 792 Lights 0.00 0 0 78 792 65 792 0 0 0 Rm Exh 203 People 0.00 0 14 142 17 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 995 Sub Total ==> 0.00 0 0 92 934 82 995 0 24 Ceiling Load 0.00 0 -40 2 24 0 0 -24 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.49 0.49 cfm/ft² 0 Ov/Undr Sizing 57.66 -708 -708 0 0 0 0 566.50 cfm/ton Exhaust Heat -0.42 5 0 -3 1,149.73 ft²/ton -10.58 10.44 Btu/hr·ft² 0.6 No. People 1,083 Grand Total ==> 100.00 -1,227 -1,171 100.00 1,019 100.00 1,211 127 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 116 Main Htg -1.2 57 70.9 95.0 0.1 1.2 1.2 57 75.7 59.2 67.6 55.0 50.9 62.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 130 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 1.2 Total Opt Vent 0.0 0.0 0.0 0 -1.2 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 137 0 0 0.00 -11.17 0.00 0.00 -3 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 5 5 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 57 57 57 0 0 0 0 0 57 57 57 0 0 0 0 0 0 203 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 12 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - Living/dining room HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 10 / 14 Mo/Hr: 9 / 14 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 69 / 53 / 49 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.4 70.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.4 70.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 70.9 75.4 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 5.50 -771 0 0 0 3 352 352 0.00 6,972 Glass Solar 0 0 70 8,191 56 6,972 0 -231 Glass/Door Cond -3,239 23.11 -3,239 -7 -849 -2 -231 0 AIRFLOWS Heating Cooling 52 Wall Cond 1.39 -194 -127 0 38 1 79 28 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 10.05 -260 Infiltration -1,409 -1,409 -3 -364 -2 -260 0 0 MinStop/Rh 40.03 6,533 Sub Total ==> -5,613 -4,775 60 7,017 56 6,913 380 670 Return 670 Internal Loads 17 17 Exhaust 2,635 Lights 0.00 0 0 23 2,635 21 2,635 0 0 0 Rm Exh 2,800 People 0.00 0 17 1,960 23 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 5,435 Sub Total ==> 0.00 0 0 39 4,595 44 5,435 0 54 Ceiling Load 0.00 0 -134 0 24 0 0 -54 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 1.69 1.69 cfm/ft² 0 Ov/Undr Sizing 60.43 -8,472 -8,472 0 0 0 0 634.78 cfm/ton Exhaust Heat -0.12 17 0 -7 375.35 ft²/ton -36.32 31.97 Btu/hr·ft² 8.0 No. People 12,022 Grand Total ==> 100.00 -14,020 -13,381 100.00 11,636 100.00 12,341 319 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 386 Main Htg -14.0 653 70.9 95.0 1.0 12.3 11.7 653 75.4 58.9 66.5 55.0 51.5 65.3 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 420 0 0 Wall 158 113 71 Humidif 0.0 0 0.0 0.0 1.0 12.3 Total Opt Vent 0.0 0.0 0.0 0 -14.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 48 0 0 0.00 -0.34 0.00 0.00 -7 Supply Air Leakage 52 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 17 17 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 653 653 653 0 0 0 0 0 653 653 653 0 0 0 0 0 0 2,800 0 Int Door 0 Ext Door 0 0 0 20.7/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 13 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - Stair hall HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 9 / 11 Mo/Hr: 9 / 11 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 63 / 50 / 44 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.2 70.9 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.2 70.9 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 70.9 75.2 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 1.36 -147 0 0 0 0 13 13 0.00 9,133 Glass Solar 0 0 102 9,133 102 9,133 0 -821 Glass/Door Cond -5,729 53.22 -5,729 -9 -821 -9 -821 0 AIRFLOWS Heating Cooling 11 Wall Cond 2.86 -308 -183 0 11 0 19 8 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 2.71 -58 Infiltration -292 -292 0 -38 -1 -58 0 0 MinStop/Rh 60.16 8,265 Sub Total ==> -6,476 -6,204 93 8,285 92 8,286 21 505 Return 505 Internal Loads 4 4 Exhaust 546 Lights 0.00 0 0 6 546 6 546 0 0 0 Rm Exh 140 People 0.00 0 1 98 2 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 686 Sub Total ==> 0.00 0 0 7 644 8 686 0 5 Ceiling Load 0.00 0 -28 0 5 0 0 -5 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 6.27 6.27 cfm/ft² 0 Ov/Undr Sizing 37.55 -4,042 -4,042 0 0 0 0 670.42 cfm/ton Exhaust Heat -0.03 4 0 -1 107.00 ft²/ton -134.56 112.14 Btu/hr·ft² 0.4 No. People 8,956 Grand Total ==> 100.00 -10,765 -10,274 100.00 8,934 100.00 8,972 16 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 80 Main Htg -10.8 501 70.9 95.0 0.8 9.0 9.0 501 75.2 56.3 54.5 55.0 48.9 54.5 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 80 0 0 Wall 293 221 76 Humidif 0.0 0 0.0 0.0 0.8 9.0 Total Opt Vent 0.0 0.0 0.0 0 -10.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -250 0 0 0.00 2.32 0.00 0.00 -1 Supply Air Leakage 63 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 4 4 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 501 501 501 0 0 0 0 0 501 501 501 0 0 0 0 0 0 140 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 14 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - West bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 76.1 69.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 76.1 69.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 69.7 76.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 16.92 -72 0 0 0 12 47 47 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 32.40 21 Infiltration -139 -139 6 20 5 21 0 0 MinStop/Rh 49.32 21 Sub Total ==> -211 -139 6 20 17 68 47 21 Return 21 Internal Loads 2 2 Exhaust 259 Lights 0.00 0 0 77 259 66 259 0 0 0 Rm Exh 67 People 0.00 0 14 47 17 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 326 Sub Total ==> 0.00 0 0 90 306 83 326 0 13 Ceiling Load 0.00 0 -27 4 13 0 0 -13 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.50 0.50 cfm/ft² 0 Ov/Undr Sizing 52.31 -224 -224 0 0 0 0 581.40 cfm/ton Exhaust Heat -0.80 3 0 -2 1,161.56 ft²/ton -11.27 10.33 Btu/hr·ft² 0.2 No. People 360 Grand Total ==> 100.00 -428 -390 100.00 339 100.00 393 32 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 38 Main Htg -0.4 19 69.7 95.0 0.0 0.4 0.4 19 76.1 59.3 67.5 55.0 51.3 64.3 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 40 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.0 0.4 Total Opt Vent 0.0 0.0 0.0 0 -0.4 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 4 0 0 0.00 -0.82 0.00 0.00 -2 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 2 2 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 19 19 19 0 0 0 0 0 19 19 19 0 0 0 0 0 0 67 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 15 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks 2 - West bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 76.1 69.7 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 76.1 69.7 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 69.7 76.1 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 11.93 -362 0 0 0 6 175 175 0.00 289 Glass Solar 0 0 12 289 11 289 0 192 Glass/Door Cond -1,454 47.88 -1,454 8 192 7 192 0 AIRFLOWS Heating Cooling 48 Wall Cond 8.81 -267 -220 2 48 2 58 10 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 0.00 0 0 0 0 0 Sec Fan 21.63 92 Infiltration -657 -657 4 94 3 92 0 0 MinStop/Rh 90.25 622 Sub Total ==> -2,741 -2,331 26 623 30 807 185 143 Return 143 Internal Loads 8 8 Exhaust 1,229 Lights 0.00 0 0 51 1,229 45 1,229 0 0 0 Rm Exh 700 People 0.00 0 20 490 26 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,929 Sub Total ==> 0.00 0 0 71 1,719 71 1,929 0 63 Ceiling Load 0.00 0 -129 3 63 0 0 -63 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.75 0.75 cfm/ft² 0 Ov/Undr Sizing 10.06 -306 -306 0 0 0 0 593.57 cfm/ton Exhaust Heat -0.54 16 0 -8 791.99 ft²/ton -16.87 15.15 Btu/hr·ft² 2.0 No. People 2,613 Grand Total ==> 100.00 -3,037 -2,765 100.00 2,405 100.00 2,727 114 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 180 Main Htg -3.0 135 69.7 95.0 0.2 2.7 2.5 135 76.1 59.6 69.2 55.0 51.8 66.7 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 0 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 200 0 0 Wall 113 51 45 Humidif 0.0 0 0.0 0.0 0.2 2.7 Total Opt Vent 0.0 0.0 0.0 0 -3.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -7 0 0 0.00 0.22 0.00 0.00 -8 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 8 8 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 135 135 135 0 0 0 0 0 135 135 135 0 0 0 0 0 0 700 0 Int Door 0 Ext Door 0 0 0 11.1/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 16 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks B - East bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.8 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 -17 Floor 68.57 -537 -537 -3 -2 -17 Sec Fan 30.30 37 Infiltration -237 -237 5 34 5 37 0 0 MinStop/Rh 98.87 20 Sub Total ==> -774 -774 2 17 3 20 0 41 Return 41 Internal Loads 3 3 Exhaust 444 Lights 0.00 0 0 66 444 62 444 0 0 0 Rm Exh 114 People 0.00 0 12 80 16 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 557 Sub Total ==> 0.00 0 0 77 523 78 557 0 1 Ceiling Load 0.00 0 -3 0 1 0 0 -1 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.58 0.58 cfm/ft² 135 Ov/Undr Sizing 0.00 0 0 20 135 19 135 638.85 cfm/ton Exhaust Heat -0.05 0 0 0 1,094.89 ft²/ton -12.04 10.96 Btu/hr·ft² 0.3 No. People 713 Grand Total ==> 100.00 -783 -777 100.00 676 100.00 712 -1 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 65 Main Htg -0.8 38 71.8 95.0 0.1 0.7 0.7 38 75.0 58.9 67.0 55.0 51.5 65.3 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 65 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.7 Total Opt Vent 0.0 0.0 0.0 0 -0.8 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -9 0 0 0.00 1.18 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 3 3 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 -17 0 0 0 0.00 0 0.00 0 0.00 38 38 38 0 0 0 0 0 38 38 38 0 0 0 0 0 0 114 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 17 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks B - East bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 9 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.8 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 245 Glass Solar 0 0 27 634 10 245 0 163 Glass/Door Cond -1,231 45.76 -1,231 -3 -62 6 163 0 AIRFLOWS Heating Cooling 55 Wall Cond 11.23 -302 -254 1 16 3 65 11 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 21.14 -569 -569 0 0 0 Sec Fan 22.66 92 Infiltration -609 -609 -1 -21 4 92 0 0 MinStop/Rh 100.79 555 Sub Total ==> -2,711 -2,663 24 567 22 566 11 138 Return 138 Internal Loads 8 8 Exhaust 1,140 Lights 0.00 0 0 49 1,140 45 1,140 0 0 0 Rm Exh 700 People 0.00 0 21 490 28 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,840 Sub Total ==> 0.00 0 0 70 1,630 73 1,840 0 2 Ceiling Load 0.00 0 -9 0 1 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.78 0.78 cfm/ft² 125 Ov/Undr Sizing 0.00 0 0 5 125 5 125 618.02 cfm/ton Exhaust Heat -0.04 1 0 0 791.97 ft²/ton -16.11 15.15 Btu/hr·ft² 2.0 No. People 2,522 Grand Total ==> 100.00 -2,690 -2,671 100.00 2,323 100.00 2,530 8 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 167 Main Htg -2.7 130 71.8 95.0 0.2 2.5 2.3 130 75.0 59.0 67.6 55.0 51.4 64.8 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 13 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 113 43 38 Humidif 0.0 0 0.0 0.0 0.2 2.5 Total Opt Vent 0.0 0.0 0.0 0 -2.7 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 20 0 0 0.00 -0.75 0.00 0.00 0 Supply Air Leakage 72 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 8 8 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 130 130 130 0 0 0 0 0 130 130 130 0 0 0 0 0 0 700 0 Int Door 0 Ext Door 0 0 0 12.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 18 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks B - Hall HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.8 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 0 Partition/Door 0.00 0 0 0 0 0 0 -37 Floor 68.57 -1,165 -1,165 -3 -2 -37 Sec Fan 30.30 80 Infiltration -515 -515 5 74 5 80 0 0 MinStop/Rh 98.87 43 Sub Total ==> -1,679 -1,679 2 36 3 43 0 89 Return 89 Internal Loads 6 6 Exhaust 962 Lights 0.00 0 0 66 962 62 962 0 0 0 Rm Exh 247 People 0.00 0 12 173 16 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,209 Sub Total ==> 0.00 0 0 77 1,135 78 1,209 0 2 Ceiling Load 0.00 0 -7 0 2 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.58 0.58 cfm/ft² 294 Ov/Undr Sizing 0.00 0 0 20 294 19 294 638.85 cfm/ton Exhaust Heat -0.05 1 0 0 1,094.89 ft²/ton -12.04 10.96 Btu/hr·ft² 0.7 No. People 1,547 Grand Total ==> 100.00 -1,698 -1,686 100.00 1,466 100.00 1,545 -2 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 141 Main Htg -1.7 82 71.8 95.0 0.1 1.6 1.5 82 75.0 58.9 67.0 55.0 51.5 65.3 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 141 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 1.6 Total Opt Vent 0.0 0.0 0.0 0 -1.7 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -20 0 0 0.00 1.18 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 6 6 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 -37 0 0 0 0.00 0 0.00 0 0.00 82 82 82 0 0 0 0 0 82 82 82 0 0 0 0 0 0 247 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 19 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks B - West bathroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 15 Mo/Hr: 7 / 14 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 87 / 63 / 70 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.8 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 0 Glass Solar 0 0 0 0 0 0 0 0 Glass/Door Cond 0 0.00 0 0 0 0 0 0 AIRFLOWS Heating Cooling 0 Wall Cond 0.00 0 0 0 0 0 0 0 -22 Partition/Door 18.20 -182 -182 -3 -22 -2 -22 -16 Floor 56.01 -562 -562 -2 -2 -16 Sec Fan 24.75 39 Infiltration -248 -248 4 35 4 39 0 0 MinStop/Rh 98.95 2 Sub Total ==> -992 -992 0 -3 0 2 0 52 Return 52 Internal Loads 3 3 Exhaust 464 Lights 0.00 0 0 54 464 51 464 0 0 0 Rm Exh 119 People 0.00 0 10 83 13 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 583 Sub Total ==> 0.00 0 0 63 547 64 583 0 1 Ceiling Load 0.00 0 -4 0 1 0 0 -1 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.71 0.71 cfm/ft² 321 Ov/Undr Sizing 0.00 0 0 37 321 35 321 643.58 cfm/ton Exhaust Heat -0.04 0 0 0 900.88 ft²/ton -14.75 13.32 Btu/hr·ft² 0.3 No. People 907 Grand Total ==> 100.00 -1,003 -996 100.00 866 100.00 906 -1 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 68 Main Htg -1.0 49 71.8 95.0 0.1 0.9 0.9 49 75.0 58.7 66.3 55.0 51.4 64.8 Main Clg Part 45 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 68 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 0 0 0 Humidif 0.0 0 0.0 0.0 0.1 0.9 Total Opt Vent 0.0 0.0 0.0 0 -1.0 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 -11 0 0 0.00 1.09 0.00 0.00 0 Supply Air Leakage 88 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 3 3 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 -17 0 0 0 0.00 0 0.00 0 0.00 49 49 49 0 0 0 0 0 49 49 49 0 0 0 0 0 0 119 0 Int Door 0 Ext Door 0 0 0 5.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 20 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM Room Checksums By BG Buildingworks B - West bedroom HEATING COIL PEAK CLG SPACE PEAK COOLING COIL PEAK TEMPERATURES Heating Design Mo/Hr: 7 / 9 Mo/Hr: 7 / 15 Mo/Hr: Peaked at Time: Cooling Heating SADB OADB: -19 OADB: 88 / 63 / 69 OADB/WB/HR: Outside Air: 55.0 95.0 Ra Plenum 75.0 71.8 Return Percent Coil Peak Space Peak Space Percent Percent Net Plenum Space 75.0 71.8 Ret/OA Sens. + Lat. Of Total Tot Sens Space Sens Of Total Sensible Of Total Total Sens. + Lat 71.8 75.0 0.0 0.0 Fn MtrTD Btu/h (%) Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h 0.0 0.0 Fn BldTD Envelope Loads 0.0 0.0 Fn Frict 0 Skylite Solar 0.00 0 0 0 0 0 0 0 0 Skylite Cond 0.00 0 0 0 0 0 0 0 0 Roof Cond 0.00 0 0 0 0 0 0 0 0.00 245 Glass Solar 0 0 27 634 10 245 0 163 Glass/Door Cond -1,231 45.76 -1,231 -3 -62 6 163 0 AIRFLOWS Heating Cooling 55 Wall Cond 11.23 -302 -254 1 16 3 65 11 0 Partition/Door 0.00 0 0 0 0 0 0 0 Floor 21.14 -569 -569 0 0 0 Sec Fan 22.66 92 Infiltration -609 -609 -1 -21 4 92 0 0 MinStop/Rh 100.79 555 Sub Total ==> -2,711 -2,663 24 567 22 566 11 138 Return 138 Internal Loads 8 8 Exhaust 1,140 Lights 0.00 0 0 49 1,140 45 1,140 0 0 0 Rm Exh 700 People 0.00 0 21 490 28 0 0 Auxiliary 0 Misc 0.00 0 0 0 0 0 0 0 1,840 Sub Total ==> 0.00 0 0 70 1,630 73 1,840 0 2 Ceiling Load 0.00 0 -9 0 1 0 0 -2 0 Ventilation Load 0.00 0 0 0 0 0 0 0 Sup. Fan Heat 0 0 ENGINEERING CKS Heating Cooling Ret. Fan Heat 0 0 0 % OA 0.0 0.0 Duct Heat Pkup 0 0 0 0.78 0.78 cfm/ft² 125 Ov/Undr Sizing 0.00 0 0 5 125 5 125 618.02 cfm/ton Exhaust Heat -0.04 1 0 0 791.97 ft²/ton -16.11 15.15 Btu/hr·ft² 2.0 No. People 2,522 Grand Total ==> 100.00 -2,690 -2,671 100.00 2,323 100.00 2,530 8 AREAS HEATING COIL SELECTION COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass Coil Airflow Ent Lvg Capacity ton MBh MBh cfm °F °F gr/lb °F °F gr/lb ft² (%) °F °F cfm MBh Floor 167 Main Htg -2.7 130 71.8 95.0 0.2 2.5 2.3 130 75.0 59.0 67.6 55.0 51.4 64.8 Main Clg Part 0 Aux Htg 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Aux Clg ExFlr 13 0.0 Preheat 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent Roof 0 0 0 Wall 113 43 38 Humidif 0.0 0 0.0 0.0 0.2 2.5 Total Opt Vent 0.0 0.0 0.0 0 -2.7 Total Envelope Loads Skylite Solar Skylite Cond Roof Cond Glass Solar Glass/Door Cond Wall Cond Partition/Door Floor Infiltration Sub Total ==> Lights People Misc Sub Total ==> Ceiling Load Ventilation Load System Plenum Heat Additional Reheat OA Preheat Diff. Ov/Undr Sizing Exhaust Heat RA Preheat Diff. Grand Total ==> Internal Loads 0 20 0 0 0.00 -0.75 0.00 0.00 0 Supply Air Leakage 72 Dehumid. Ov Sizing 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Leakage Ups Leakage Dwn 8 8 Infil AHU Vent Nom Vent Main Fan Terminal Adjacent Floor Diffuser Supply Air Leakage Underflr Sup Ht Pkup Underflr Sup Ht Pkup Adjacent Floor 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0 0.00 0 0.00 130 130 130 0 0 0 0 0 130 130 130 0 0 0 0 0 0 700 0 Int Door 0 Ext Door 0 0 0 12.0/1000 ft² TRACE® 700 v6.3.2 calculated at 11:46 AM on 04/20/2017 Project Name: Dataset Name: Alternative - 1 System Checksums Report Page 21 of 21 9762ROWHOUSE12.TRC DRB APPROVED 12/2/2017 8:43:40 AM