HomeMy WebLinkAboutDRB17-0269_A0 Cover_1498771200.pdf lei OF gr,
4.11:1"0
464:0
___.
*n
MEADOW VAIL PLACE UNIT 3 .
Od
DRB
APPROVE
6
6/29/2017
12:00:00.12:00:00 1 M
44 W ST \., ADOW DH V VA L COLOHADO
9 9
STANDARD ASSREV I ATI ONS SENERAL NOTES
m'.M
O
Ccb�
=
I. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO d I�o'
A.F.F. ABOVE FINISHED FLOOR JT. JOINT - ..co
A.F.0 ABOVE FINISHED GRADE LAM. LAMINATE CONSTRUCTION. CONTRACTOR TO NOTIFY ARCHITECT IF EXIST. CONDITIONS ARE
AGOUS. ACOUSTICAL LAV. LAVATORY NOT COMPATIBLE WITH PROPOSED. I . o°fo
ADJ. ADJUSTABLE LIN. LINEN 'C 0 o rn
ANGH. ANCHOR LT. LIGHT SGOPE OF REMODEL 2. CONTRACTOR 15 RESPONSIBLE FOR MAINTAINING THE INTEGRITY OF ALL 6 -1-+ o ix
APP. APPROXIMATELY - Eta
LT.WT. LIGHTWEIGHT
ARCH. ARCHITECTURAL M.H. MANHOLE REQUIRED FIRE SEPARATION SYSTEMS. o 0
� s waw
ATTEN. ATTENUATION M.O. MASONRY OPENING 3. CONTRACTOR TO VERIFY LOCATION AND ADEQUACY OF ALL EXIST. UTILITIES A L N
AWN AWNING MACH. MACHINE I. ASBESTOS TESTING AND ABATEMENT TO OGGUR AT ALL CONSTRUCTION AREAS Q co
BDRM. BEDROOM M. MASTER
PRIOR TO CONSTRUCTION. AND CONNECTIONS. Fo
BD. BOARD MAX. MAXIMUM °
BLDG. BUILDING MECH. MECHANICAL 2. ENCLOSE EXISTING DECK AT BEDROOM 4. 4. DO NOT SCALE OFF DRAWINGS. 6 ^o
BLK. BLOCK MTL. METAL �1 x o
BLR. BOILER MANUF. MANUFACTURER 3. FIRE SPRINKLE ALL SPACES. 5. DIMENSIONS TO FACE OF STUD. mcg
BM. BEAM MIN. MINIMUM C
B. BOTTOM Mkt MICROWAVE 4. NEW MECHANICAL SYSTEMS TO PROVIDE HEATING, AIR CONDITIONING AND 6. CONTRACTOR TO COORDINATE WITH OWNER ANY ITEMS TO REMAIN OR TO BE aQ
G.B. GATGH BASIN MTD. MOUNTED HUMIDIFICATION TO ALL SPACES. EACH BEDROOM TO HAVE INDEPENDENT SALVAGED.
G.G. CORNER GUARD N.I.C. NOT IN CONTRACT CONTROLS.
G.J. CONTROL JOINT NEG'Y NECESSARY 1 CONTRACTOR SHALL PERFORM NO WORK WHICH MAY IMPACT ADJACENT
G.M.U. CONCRETE MASONRY UNIT (N) NEW 5. ALL TRIM AND CASING TO BE SELECTED. NEW DOORS TO BE STAIN GRADE FINISH. PROPERTIES.
C.O. GLEAN OUT NOM. NOMINAL
C.T. CERAMIC, TILE O.G. ON CENTER 6. ALL NEW KITCHEN. S. CONTRACTOR TO COORDINATE WITH ALL DISCIPLINES (M/E/S/FP) PRIOR TO
GAB. GAB INET O.D. OUTSIDE DIAMETER CONSTRUCTION.
GEM. GEMENT OPG. OPENING 7. ALL PLUMBING FIXTURES, TUBS, TOILETS AND SINKS TO BE REPLACED. SHOWERS
GER. CERAMIC PT. PAINT TO REPLACE TUBS AT ALL BEDROOMS. q. CONTRACTOR TO FIELD VERIFY T.O. STRUCTURAL SLABS PRIOR TO O
GLC. CEILING PARTN. PARTITION CONSTRUCTIONCr)
M/
.
CLOS. CLOSET PVRS PAVERS S. NEW VANITIES AT ALL BATHROOMS WITH NEW FAUCETS AND CONTROLS TO BE n
GLR. CLEARANCE PH. PHONE SELECTED BY INTERIOR DESIGNER.
COL. COLUMN PL. PLATE 10. RADON MITIGATION - A METHOD OF "PASSIVE VENTING" SHALL BEFm
CON. CONCRETEINCORPORATED INTO THE MECH. SYSTEM.
PLAS. PLASTER q. EXPAND MAIN LIVING SPACE ONTO EXISTING DECK AREA. ENGINEERED WOOD
CONT. CONTINUOUS PLNK. PLANK FLOOR AT INTERIOR AND ROOF DECK PAVERS OVER SLOPED DRAIN ASSEMBLY AT ~_
CONST. CONSTRUCTION PLWD. PLYWOOD EXTERIOR. TWO DRAINS. II. ENTIRE REMODEL SHALL BE FIRE PROTECTED WITH AN INTEGRATED FIRE 0
GPT. CARPET PORG. PORCELAIN SPRINKLER SYSTEM. DESIGN BY OTHERS. RE: SPECS.
D. DRYER Q.T. QUARRY TILE 10. ENCLOSE SMALL DECK AT WEST SIDE OF LIVING ROOM AND PROVIDE A NEW
D.W DISHWASHER R. RISERS DECK AT THE NEW LOFT SPACE ABOVE. 12. GAS FIREPLACES: MANUF. ff SIZE TO BE DETERMINED. RE: MANUF. SPECS WHEN
DBL. DOUBLE R.D. ROOF DRAIN SIZE a TYPE DETERMINED. ! _I
DET. DETAIL R.O. ROUGH OPENING II. NEW DRYWALL WALLS TO HAVE SMOOTH FINISH. SATIN PAINT. l 0
DIA., DIAMETER RAD. RADIUS 13. ALL FURRING SHALL BE 2"X4" U.O.N. STEEL FRAMING CONSTRUCTION WITH v
DI AG. DIAGONAL RE: REFERENCE [Ti
DIM. DIMENSION REG. RECESSED 12. HEATING, COOLING AND HUMIDIFICATION TO BE PROVIDED BY CONTRACTOR AT ACOUSTIC BATT INSULATION. 4 7
DN. DOWN REF. REFRIGERATOR ALL SPACES. MEGH SYSTEMS TO BE DESIGNED BY MECH ENGINEER AND
DR. DRAIN REINF. REINFORCED COORDINATED WITH CONTRACTOR AND ARCHITECT FOR FINISH 14. ALL INTERIOR AND EXTERIOR SHALL BE 2"X6" U.O.N. STEEL FRAME l rTl
DWG. DRAWING REG'D REQUIRED RES. RESISTANT CEILING HEIGHTS AND DUCTWORK LOCATIONS. ZONING AND T. STAT LOCATIONS CONSTRUCTION WITH R21 FULL BATT ACOUSTIC INSULATION. v w O
DUMPSTR. DUMPSTER TO BE DETERMINED.
E.J. EXPANSION JOINT RESIL. RESILIENT 15. ALL T.O.FLR, T.O.GONG., T.O.DECK, T.O.W ETC. SHALL BE DEFINED AS TOP OF 44: /I�)
EA. EACH RET. RETAINING 13. REMOVE EXISTING WOOD BURNING FIREPLACE AND PROVIDE A GAS BURNING FINISH MATERIAL. �� O
EL. ELEVATION REV. REVISION FIRE PIT AT EXTERIOR DECK AREA. O T� (-
ELECT. ELECTRICAL RM. ROOM 16. ALL WALL TILE LOCATIONS SHALL HAVE GEMENT ITIOUS BACKER BOARD. U.O.N. V 1
ENG. ENGINEER 5.5. STAINLESS STEEL 14. NEW BUILT IN GAS BARBEQUE WITH PIZZA OVEN AT EAST SIDE OF DECK AREA. pl.. 4.1WOEQ. EQUAL S.V. SHEET VINYL UNIT TO BE SPECIFIED. 11 ALL NEW WINDOWS AND DOORS TO HAVE STEEL FRAMES TO MATCH EXISTING.. w
EQUIP. EQUIPMENT SCHED. SCHEDULE p4 > 0
EXIST. EXISTING SECT. SECTION 15. RECONFIGURE CLOSETS AND BATHROOMS AT ALL BEDROOMS. 18. BASE: I" X 6", STAIN GRADE, PROFILE TO BE DETERMINED BY OWNER. I'l OY U
EXP. EXPANSION SHT. SHEET
EXT. EXTERIOR SHLVS. SHELVES 16.NEW DOOR HARDWARE THROUGHOUT.
161. ALL REPLACEMENT GLAZING SHALL BE DOUBLE PANED LOW-E GLASS.
F.D. FLOOR DRAIN SIM. SIMILAR W
FON. FOUNDATION SPEC, SPEC IFIGAT ION 17. NEW FINISHES THROUGHOUT.
FIN. FINISH SQ. SQUARE 20. HEATING AND AIR CONDITIONING TO BE PROVIDED BY CONTRACTOR. MECH
Ur
FLR. FLOOR SYSTEMS TO BE DESIGNED BY MEGH ENGI NEER AND COORD I NATED W 1 TH 1 Q
ST. STAIN 18. ALL COMMON WALLS TO MAINTAIN I HOUR FIRE RATING BETWEEN UNITS.
FIX. FIXTURE STD. STANDARD
CONTRACTOR AND ARCHITECT FOR FINISH CEILING HEIGHTS AND DUCTWORK
FLUOR. FLUORESCENT STL. STEEL LOCATIONS. ZONING AND T. STAT LOCATIONS TO BE DETERMINED. ' O W
FREZ. FREEZER STRUCT. STRUCTURAL
FRM. FRAME SUSP. SUSPENDED N
FT. FOOT T. TREADS
FTG. FOOTING TB TOWEL BAR
C.I. GALVANIZED IRON T$B TOP AND BOTTOM
CFP. GAS FIRE PLAGE T$6 TONGUE AND GROOVE
GA. GAUGE T.O.G. TOP OF CONCRETE O O
GALV. GALVANIZED TEL. TELEPHONE
GEN. GENERAL THRU THROUGH
GL. GLASS T.P.H TOILET PAPER HOLDER PRELIMINARY -- 1-
GIRT. GROUT T.O. TOP OF /1
GYP. GYPSUM T.O.V. TOWN OF VA IL l./ l
CB. GYPSUM BOARD T.O.W. TOP OF WALL NOT FOR CONSTRUCTION I
H.B. HOSES IB T.V. TELEVISION
H.M. HOLLOW METAL TYP. TYPICAL 2 CONCRETE ON
STEEL DECKING ON °..:° °.. ° °.. ° °.. ° °.. ° °..
HDRL. HAND RAIL OPEN WEB BAR JOISTS a' v v v a v v
HD. HEAD U.O.N. UNLESS OTHERWISE NOTED ^� „ �^'�` ; j ‘%, ;/g
V.G.P. VITRIFIED CLAY PIPE 024.'00.
HDWD. HARDWOOD V.G.T. VINYL COMPOSITION TILE
(HORIZ. H) HORIZONTAL VERT. V) VERTICAL \ NI
HT. HEIGHT W. WASHER ,„ NI
HTR. HEATER W.G. WATER CLOSET
IN. INCH W.F. WIDE FLANGE I,�I /�
INSUL. INSULATION W.P. WATERPROOF INDEX OF DRAY I NSS ISSUANCE
INT. INTERIOR W.W.F. WELDED WIRE FABRIC, USG DGL DRYWALL
INV. INVERT WATER-RES. WATER RESISTANT SUSPENSION SYSTEM .
J.B. JUNCTION BOX WD. WOOD SHT.WITHOUT TYPE "X" ✓I �T. DESG IFTION
GI ILETROGK WITH
FINISHED JOINTS
AND TH
r ---
2 ROUND ± PLUS OR MINUS PLASTER FINISH. DESIGN
NO. PERMIT REVISIONS REVISIONS
W/ WITH R PROPERTY LINE
° DEGREES 4 ANGLE
EP SQUARE FOOT k CENTER LINE
a I I I i� I AO GOVERSHEET AND NOTES
IC- -4.I I HOUR. FLOOR GE I L I Ne ASSEM5i.Y A I EXISTING ENTRY LEVEL AND DEMOLITION PLAN
ED
A2 EXISTING BUILDING ELEVATIONS
SCALE: I" = I'- 0" UL DESIGNATION 6528 USC
A5 NEW FLOOR PLAN
DRAhI I NO CONVENT I ONS
A4 LOFT PLAN
DETAIL DESIGNATOR 105 DOOR DESIGNATOR ADM I N I STAT I VE S SOUTH BUILDING ELEVATION
0I6 DETAIL NUMBER EAST BUILDING ELEVATION
C
SHEET WHERE SHOWN A GLAZING DESIGNATOR CONTRACTOR:
R.A. NELSON CONSTRUCTION BUILDING TYPE: HEST BUILDING ELEVATION
® SPUNE----------------------------------
CONTACT: ERIK GARGIA (q70) 748-7657 BUILDING TYPE II
FAX: (CT: ERI
GA FOUR STORY STUCCO RESIDENTIAL WITH A& BUILDING SECTION
BLDG. SECTION DESIGNATOR WOOD TRIM. BUILDING IS TO BE FIRE
IYECTION
LETTER SPRINKLED AT INTERIOR AND GARAGE. DETAILS. WINDOW AND DOOR SCHEDULE DATE:
I
MEGHANIGAL AND ELEGTRIGAL ENGINEER:
EET WHERE SHOWN OFFICE ROOM NAME RADER ENGINEERING E I ELECTRICAL SCHEMATIC PLAN
CONTACT: DREW RADER (q70) 845-7x10 STRUCTURAL CONSULTANT: 28 APRIL 2011
100 ROOM NUMBER FAX: (d170) 845-7522 KRM ENGINEERING
• 100-0
LEVEL INDICATOR CONTACT: TIM HENNUM (ci7O) q41-g3g1
INTERIOR DESIGN:
-o REVISED AREA S I STRUCTURAL COVER SHEET
• loo
OF DRAWING
SPOT ELEVATION FIRE PROTECTION: 52
STRUCTURAL PLAN
WESTERN STATES FIRE PROTECTION COMPANY
INTERIOR ELEVATION DESIGNATOR CONTACT: JOE HAYDEN (d170) 618-32(14 55 STRUCTURAL DETAILS
CELL: (303) 54(1-8g7q SHEET
4' 60 IA SECTION LETTER OOR ENTOFERLINE r OWNERS REPRESENTATIVE:
� SHEET WHERE SHOWN
i
KAREN LEE (5170) 476-4271 MI MECHANICAL COVER SHEET
i DIMENSION CONVENTION PRESIDENT: RICHARD LIEBHABER
A 0AM"
BLDG. ELEVATION DESIGNATOR M2 SCHEMATIC PLAN
40 M5 DETAILS AND SPECS /