Loading...
HomeMy WebLinkAboutDRB17-0276_MXZ-3C24NA2_Submittal For DRB approval_1499282220.pdf Job Name: System Reference: Date: il �Iliolllllllllllllllluum�,, oi 11111111111111111111111111111111111111111111111 '11111..11ll�iiiill1111111IIIIpDi"' 1 .�t Outdoor Unit:MXZ-3C24NA2 ACCESSORIES o 3/8"x 1/2"Port Adapter(MAC-A454JP-E) o 1/2"x 3/8"Port Adapter(MAC-A455JP-E) o 1/2"x 5/8"Port Adapter(MAC-A456JP-E) o M-NET Adapter(PAC-IFO1MNT-E) o Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C24NA2 Rated Capacity Btu/h 22,000/23,600 Cooling* Capacity Range Btu/h 12,600-22,000/12,600-25,500 (Non-ducted/Ducted) Rated Total Input W 1,620/2,100 Rated Capacity Btu/h 25,000/24,600 Heating at 47°F* Capacity Range Btu/h 11,400-30,600/11,400-29,400 (Non-ducted/Ducted) Rated Total Input W 1,750/1,900 Heating at 17°F* Rated Capacity Btu/h 14,000/14,000 (Non-ducted/Ducted) Rated Total Input W 2,120/2,230 Energy Star®(ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) Yes Power Supply Voltage,Phase,Hertz 208/230V, 1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Sound Pressure Level Cooling dB(A) 51 (Non-ducted/Ducted) Heating 55 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 137(62) External Finish Munsell 3.0Y 7.8/1.1 Refrigerant Pipe Size O.D. Liquid(High Pressure) In(mm) 1/4(6.35) Gas(Low Pressure) A Port: 1/2(12.7);Other:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared Refrigerant R410A *Rating Conditions per AHRI Standard: Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB Heating at 17°F I Indoor:70°F(21°C)DB Cooling I Outdoor:95°F(35°C)DB/23.9°C(75°F)WB Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)WB Heating at 17°F I Outdoor:17°F(-8°C)DB/15°F(-9°C)WB Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: MXZ-3C24NA2 OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted 20.0 13.6 9.8 4.2 2.97 Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) Ducted and 18.0 12.4 9.5 4.0 2.79 Non-ducted Ducted 16.0 11.2 9.2 3.8 2.61 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C24NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-3C24NA2 OPERATIONAL PERFORMANCE NON-DUCTED: #of Total Nominal Operational Performance for Cooling Capacity Range(Btu/h) indoor Capacity Total Indoor Unit Indoor Unit Combinations Heating Capacity Range(Btu/h) unit (x1000 Btu/h) Capacity(Btu/h) (Unit A+Unit B+Unit C) Unit A Unit B Unit C 1 6 6,000 6 6,000 - - 7,400 7,400 - - 9,000 9,000 - - 1 9 9 11,000 11,000 - - 1 12 12,000 12 12,000 - - 14,400 14,400 - - 1 15 14,000 15 14,000 - - 18,000 18,000 - - 1 18 17,200 18 17,200 - - 21,600 21,600 - - 2 12 12,000 6+6 6,000 6,000 - 14,800 7,400 7,400 - 2 15 14,000 6+9 5,600 8,400 - 18,400 7,400 11,000 - 2 18 18,000 6+ 12 6,000 12,000 - 22,000 7,500 14,500 - 18,000 9+9 9,000 9,000 - 2 18 22,000 11,000 11,000 - 20,000 6+ 15 6,000 14,000 - 2 21 22,000 6,400 15,600 - 20,000 g+ 12 8,600 11,400 - 2 21 22,000 9,500 12,500 - 21,800 5,600 16,200 - 2 24 6+ 18 24,000 6,100 17,900 - 2 24 21,800 12+ 12 10,900 10,900 - 24,000 12,000 12,000 - 21,800 8,500 13,300 - 2 24 9+ 15 24,000 9,100 14,900 - 21,800 7,500 14,300 - 2 27 9+ 18 24,000 8,100 15,900 - 21,800 10,100 11,700 - 2 27 24,000 12+15 10,700 13,300 - 3 18 18,000 6+6+6 6,000 6,000 6,000 22,000 7,300 7,300 7,300 3 21 21,000 6+6+9 6,000 6,000 9,000 24,800 7,100 7,100 10,600 22,000 5,500 5,500 11,000 3 24 25,000 6+6+12 6,300 6,300 12,300 3 24 22,000 g+g+g 5,500 8,300 8,300 25,000 6,300 9,400 9,400 24,000 5,500 5,500 12,900 3 27 25,000 6+6+ 15 5,600 5,600 13,700 3 27 24,000 g+g+ 12 5,300 8,000 10,700 25,000 5,600 8,400 11,000 24,000 9+9+9 8,000 8,000 8,000 3 27 25,000 8,300 8,300 8,300 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. MXZ-3C24NA2 OPERATIONAL PERFORMANCE, contd. DUCTED: #of Total Nominal Operational Performance for Cooling Capacity Range(Btu/h) indoor Capacity Total Indoor Unit Indoor Unit Combinations Heating Capacity Range(Btu/h) - unit (x1000 Btu/h) Capacity(Btu/h) (Unit A+Unit B+Unit C) Unit A Unit B Unit C 1 9 9,000 9 9,000 - - 10,900 10,900 - 1 12 12,000 12 12,000 - I - 13,600 13,600 - 15,000 15,000 I I - 1 15 18,000 15 18,000 I - 1 18 17,200 18 17,200 - I - 21,600 21,600 - 2 18 18,000 9+9 9,000 _ 9,000 I - 21,800 10,900 10,900 2 21 21,000 g+ 12 9,000 12,000 - 22,000 9,800 12,200 21,800 _ 10,900 10,900 I - 2 24 24,000 112+ 12 12,000 12,000 21,800 8,200 13,600 - 2 24 9+ 15 24,000 I9,100 14,900 I I 21,800 I 7,500 _� 14,300 I - 2 27 24,000 19+ 18 8,000 16,000 I - 2 27 21,800 12+ 15 9,700 _ 12,100 - 24,000 10,300 I 13,700 I - 3 27 21,800 9+9+9 7,300 7,300 7,300 24,600 8,200 8,200 8,200 Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. DIMENSIONS: MXZ-3C24NA2 Unit: inch (mm) 6-7/8' 23-5/8' 6-7/8° Reor Air illfoke 2-13/16" 1/16' 4-19/32" 2-1/32' NG I 2-U Shaped Notched Hole 13/32" II ElmN (Foundation Bolt M10) Side Air Intake b rn 4. 7i. 6-01-5/16'Drain HoleN 113/32' irl b u s�harge 13/",, 2-(15/32"x1-13/32")Oval Hole 1-1/32" 2-07/8"knockout hole (Foundation Bolt 1,110) 1-1/2' I (Connectin. wire hole) 1-5/8' 37-13/32° 31/32' 13" 19/32' Handle 'I7"m, (Connecting/ c wire hone) , lommmirimmml II I '''''1.1 andle { � Handle Ill) I Hantlle ' ' i- . o uul�llll lllol 1111)Iliiu a II Illlluilii vMit I g IIIIIIIIIIIIIIIIIIIVI��IIllllllllllllll"I' = I 2-3/4" ----zl -- o I iliES iIIIIIIII'II;IIIII1 iiiiIlill�IIIIIIIIIIIIIIfIIi . �I �'I Air Intake IlllllllllllllllllllMP�IIIIIIIIIIIIII' Allii...'.,11.11 M/11nln l'I Gi II La unit C .. r I -- I I® I ISI, rn ,IialI GAS1 GLIOA 1/4"106.35/FLARE I I® IVdIIIIIIh1111111111Pu ;II� �I LIa }Unif B 1 GAS 3/BY0952IFLARE IiIIIIIIIIVIIIII.IIpIGAS — 1 I i �® II 'Al GAS}Unit A— GAS 1/2%0 237)FLARE 4 11-11/32" 14-7/32' 1.FREE SPACE E E E 3-15/16' or more o�Ii =0= 8ii 3-15/16' or more 13-25/32' or more ��iu. Conduit plates 2.SERVICE SPACE E °t'°�'°'°'O�T; Conduit connector 1 .� ,I__ =wls Lock nut 3-15/16' or more MEM SERVICE SPACE 13-25/32' or more 13-25/32' or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com La en...'CERTIFIED,. c E 1 I us uNlansmsllxF 40,0 VHHISimOs0210210 FORM#MXZ-3C24NA2 for Multiple Indoor Unit Styles-201611 ti .�.em...m.�. ..m Intertek Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc.