HomeMy WebLinkAboutB17-0142_GA File WP 1296_1500670380.pdf I
==.-600-2006 FIRE RESISTANCE DESIGN MANUAL
WALLS AND INTERIOR PARTITIONS, NONCOMB ec01°
1
GA FILE NO. WP 1296 L PROPRIETARY* 1 HOUR l 40 to 143 eft.
b
FIRE SO
GYPSUM WALLBOARD,STEEL STUDS, ,)IQo
MINERAL FIBER INSULATION, FIBER-CEMENT BOARD I I
_-.e layer 5/8" proprietary type X gypsum wallboard applied parallel to ONE SIDE of 35/8" 07/21/1-
steel studs 16"o.c.with 1"Type S drywall screws 8"o.c. at vertical joints and 12" o.c. i i . , ; , ,
at intermediate studs. 31/2" mineral fiber insulation, 3.0 pcf,friction fit in stud space. + .` t j ++� +
2RPOSITE SIDE: One layer 7/16 proprietary fiber-cement board applied parallel to studs ,', f. .
4with 1" No. 8-18 x 0.323" head diameter ribbed bugle head screws 6"o.c. (NLB)
PROPRIETARY GYPSUM BOARD Thickness: 43/4"
9 B America Inc. 5/8" ProRoc®Type X Gypsum Panels Approx.Weight: 7.5 psf
Fire Test: OPL 11710-92783,2-13-92
Sound Test: See WP 1350
(NGC 2385,7-28-70)
GA FILE NO. WP 1311 1 PROPRIETARY* 1 1 HOUR 1 I 35 to 39 STC
FIRE I i SOUND
SOLID GYPSUM WALLBOARD
One layer 1/2" regular gypsum wallboard or gypsum veneer base applied parallel to each I j I i
side of 1" x 24" proprietary type X gypsum panels with laminating compound combed
over the entire contact surface and 15/is" Type S screws 24" o.c. horizontally and ' 1
vertically. 1"gypsum coreboard panels attached to 25 gage 1"x 21/4" high "L" runners
along floor and ceiling lines with two 15/16"Type S screws at top and bottom.Wallboard
layers attached to"L" runners with 17/s"Type S screws 12"o.c.
Joints staggered 12"each layer and side. (NLB) Thickness: 2"
PROPRIETARY GYPSUM BOARD Limiting Height: 11'0"
Approx.Weight: 8 psf
National Gypsum Company - 1"Gold Bond®Brand FIRE-SHIELD®
Shaftliner Fire Test: FM WP-671, 6-28-82
Sound Test: Based on NGC 2359,
11-18-69
GA FILE NO. WP 1330 I GENERIC 1 HOUR 35 to 39 STC
FIRE SOUND
SEMI-SOLID GYPSUM WALLBOARD, GYPSUM STUDS
' One layer 5/8"type X gypsum wallboard or gypsum veneer base applied parallel to each
side of 6"wide gypsum studs 24"o.c. with 1"Type G drywall screws 20"o.c. and with 4- { i
laminating compound. Gypsum studs fabricated from 2 or 3 layers of 1/2" or 5/8"
laminated gypsum panels. Fire tested with 1"thick gypsum studs.
Sound tested with 5/8"thick gypsum studs. (NLB)
Thickness: Varies
Limiting Height: 12'0"
Approx.Weight: 8 psf
Fire Test: UL R2717-19,-21,6-3-57,
UL Design U510;
ULC Design W502
Sound Test: Based on G&H BW-8FT,
8-1-62
pi
6