Loading...
HomeMy WebLinkAboutElectrical Scope of work.pdf J ABG BUILDINGWORKS systems fulfilled September 07, 2016 Mr. John Halloran GE Johnson Construction Company 40800 Highway 6, Suite 8 PO Box 8809 Avon, CO, 81620 RE: 5157 Gore Circle Residence - Electrical Permit Letter Dear Mr. Halloran, Please issue the following letter and attachments to the Town of Vail for the residence at 5157 Gore Circle: Project Scope • The project includes minor interior renovations of a 3,769 square foot residence. • Renovations will be limited to interior wall removal and/or relocation. Square footage of residence will not be effected by the renovations. • Electrical equipment, mechanical equipment, cooking equipment, and appliances shall remain as existing. Load Justification • Please see attached one-line diagram and NEC load calculation for the residence. Service load is calculated using the standard method as outlined in NEC article 220, section III. • The existing service consists of a transformer and meter located on an adjacent property serving power to a 120/240 volt, single phase, 200 ampere main breaker panelboard in the basement utility room. • All equipment used in the load calculation is based on existing equipment within the residence. A future hot tub is also assumed in the calculation. • The load calculation for the residence comes to 183.3 amperes at 240 volt, single phase on the 200 ampere service. Sincerely, ^.,.�...��� �,' — pOO LtCF;_y oo••o°os %—c e..s/ , , , ART �f�r�' eQ7.2 A.7973 ›o 401 Tim McCabe 'P • . Al i Electrical Engineer j,, `° Colorado PE License#47978 `� ,�a��+'•0 o cc: Encore Electric - Eric Bankert, Toby Debele q/7/76 BG Buildingworks - Dan Koelliker, Marc Sacconi ALBUQUERQUE • AVON • DENVER • FORT COLLINS www.bgbuildingworks.com